help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 2: 199-212 (1962)
© 1962 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Prothero, J. W.
Right arrow Articles by Burton, A. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Prothero, J. W.
Right arrow Articles by Burton, A. C.

The Physics of Blood Flow in Capillaires

II. The Capillary Resistance to Flow

J. W. Prothero and A. C. Burton

ABSTRACT

A previous communication described the peculiar motion of the plasma trapped between erythrocytes in a capillary (bolus flow). In this paper the effect of this motion on capillary resistance to flow, as well as on dissipative effects associated directly with the cells, are described. The resistance that would be associated with plasma in bolus flow at high Reynolds numbers (relative to a capillary value of 0.01) was studied in a model, in which air bubbles, separated by short segments of water, passed along a glass tube. The resistance to flow, especially with short boluses, was at least ten times greater than that associated with Poiseuille flow. In a second series of experiments at lower Reynolds numbers, a single bolus of liquid was forced by air pressure along a glass tube. In these latter experiments, which more closely simulate biological conditions, the mean resistance to flow was only 30 per cent greater than that associated with Poiseuille flow. In the final series of experiments human blood and plasma, diluted in acid-citrate dextrose (A.C.D.) in varying degrees, were forced through glass micropipettes of capillary dimensions. The mean apparent viscosity of whole blood was found to exceed that of plasma by only about 5 per cent, thus verifying a conjecture to this effect made by Fahraeus and Lindqvist in 1931.




This article has been cited by other articles:


Home page
ScienceHome page
M. I. Gregersen, C. A. Bryant, W. E. Hammerle, S. Usami, and S. Chien
Flow Characteristics of Human Erythrocytes through Polycarbonate Sieves
Science, August 18, 1967; 157(3790): 825 - 827.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1962 by the Biophysical Society.