help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 36: 677-695 (1981)
© 1981 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lim, J J
Right arrow Articles by Fischbarg, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lim, J J
Right arrow Articles by Fischbarg, J

Electrical properties of rabbit corneal endothelium as determined from impedance measurements.

J J Lim and J Fischbarg

ABSTRACT

Alternating- and direct-current electrical characteristics of rabbit corneal endothelium were studied under varying experimental conditions. The measurements were performed by sending a 10-microA current (AC or DC) across the tissue layer. Maximal values of transendothelial potential difference and resistance were 1.3 +/- 0.1 mV and 73 +/- 6 omega . cm2, respectively. The short-circuit current was estimated from the potential and resistance values. Impedance loci were obtained for the frequency range 0.5-100 kHz. A capacitive reactance (C = 0.63 +/- 0.02 microF/cm2) was observed in the 100 Hz-100 kHz range. To relate the impedance data to the electrical parameters of the cell membranes, the voltage-divider ratio was determined by sending square pulse across the tissue and measuring voltage responses across the apical and basal membranes with an intracellular microelectrode. The intracellular potential difference was on the average -61 +/- 1 mV, and the voltage-divider ratio was found to be between 0.33 and 4. Impedance data were fit by a computer to an equivalent circuit representing a "lumped" model, and the agreement between the model and the data was satisfactory. The results are discussed in terms of both the morphological characteristics and properties of the fluid transport mechanism across the preparation.




This article has been cited by other articles:


Home page
Arch OphthalmolHome page
J. H. Lass, S. A. Khosrof, J. K. Laurence, B. Horwitz, K. Ghosh, I. Adamsons, and for the Dorzolamide Corneal Effects Study Group
A Double-Masked, Randomized, 1-Year Study Comparing the Corneal Effects of Dorzolamide, Timolol, and Betaxolol
Arch Ophthalmol, August 1, 1998; 116(8): 1003 - 1010.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the Biophysical Society.