| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Biophysical Journal 43: 103-114 (1983)
© 1983 the Biophysical Society
ABSTRACT
An experimental application of total internal reflection with fluorescence correlation spectroscopy (TIR/FCS) is presented. TIR/FCS is a new technique for measuring the binding and unbinding rates and surface diffusion coefficient of fluorescent-labeled solute molecules in equilibrium at a surface. A laser beam totally internally reflects at the solid-liquid interface, selectively exciting surface-adsorbed molecules. Fluorescence collected by a microscope from a small, well-defined surface area approximately 5 micron2 spontaneously fluctuates as solute molecules randomly bind to, unbind from, and/or diffuse along the surface in chemical equilibrium. The fluorescence is detected by a photomultiplier and autocorrelated on-line by a minicomputer. The shape of the autocorrelation function depends on the bulk and surface diffusion coefficients, the binding rate constants, and the shape of the illuminated and observed region. The normalized amplitude of the autocorrelation function depends on the average number of molecules bound within the observed area. TIR/FCS requires no spectroscopic or thermodynamic change between dissociated and complexed states and no extrinsic perturbation from equilibrium. Using TIR/FCS, we determine that rhodamine-labeled immunoglobulin and insulin each nonspecifically adsorb to serum albumin-coated fused silica with both reversible and irreversible components. The characteristic time of the most rapidly reversible component measured is approximately 5 ms and is limited by the rate of bulk diffusion. Rhodamine-labeled bivalent antibodies to dinitrophenyl (DNP) bind to DNP-coated fused silica virtually irreversibly. Univalent Fab fragments of these same antibodies appear to specifically bind to DNP-coated fused silica, accompanied by a large amount of nonspecific binding. TIR/FCS is shown to be a feasible technique for measuring absorption/desorption kinetic rates at equilibrium. In suitable systems where nonspecific binding is low, TIR/FCS should prove useful for measuring specific solute-surface kinetic rates.
This article has been cited by other articles:
![]() |
J. Ries, E. P. Petrov, and P. Schwille Total Internal Reflection Fluorescence Correlation Spectroscopy: Effects of Lateral Diffusion and Surface-Generated Fluorescence Biophys. J., July 1, 2008; 95(1): 390 - 399. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. P. Burghardt, J. E. Charlesworth, M. F. Halstead, J. E. Tarara, and K. Ajtai In Situ Fluorescent Protein Imaging with Metal Film-Enhanced Total Internal Reflection Microscopy Biophys. J., June 15, 2006; 90(12): 4662 - 4671. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Gavutis, S. Lata, P. Lamken, P. Muller, and J. Piehler Lateral Ligand-Receptor Interactions on Membranes Probed by Simultaneous Fluorescence-Interference Detection Biophys. J., June 1, 2005; 88(6): 4289 - 4302. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Lieto and N. L. Thompson Total Internal Reflection with Fluorescence Correlation Spectroscopy: Nonfluorescent Competitors Biophys. J., August 1, 2004; 87(2): 1268 - 1278. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Lieto, R. C. Cush, and N. L. Thompson Ligand-Receptor Kinetics Measured by Total Internal Reflection with Fluorescence Correlation Spectroscopy Biophys. J., November 1, 2003; 85(5): 3294 - 3302. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. L. Ross and D. K. Fygenson Mobility of Taxol in Microtubule Bundles Biophys. J., June 1, 2003; 84(6): 3959 - 3967. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Lagerkvist, Z. Foldes-Papp, M. A.A. Persson, and R. Rigler Fluorescence correlation spectroscopy as a method for assessment of interactions between phage displaying antibodies and soluble antigen Protein Sci., August 1, 2001; 10(8): 1522 - 1528. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Maiti, U. Haupts, and W. W. Webb Fluorescence correlation spectroscopy: Diagnostics for sparse molecules PNAS, October 28, 1997; 94(22): 11753 - 11757. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. G. Walter, P. Schwille, and M. Eigen Fluorescence correlation analysis of probe diffusion simplifies quantitative pathogen detection by PCR PNAS, November 12, 1996; 93(23): 12805 - 12810. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |