help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 55: 663-671 (1989)
© 1989 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rakowski, R F
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rakowski, R F

Simultaneous measurement of changes in current and tracer flux in voltage-clamped squid giant axon.

R F Rakowski

Department of Physiology and Biophysics, University of Health Sciences, Chicago Medical School, Illinois 60064.

ABSTRACT

A method is described for the simultaneous measurement of changes in membrane current and unidirectional radiotracer flux in internally dialyzed voltage-clamped squid giant axons. The small currents that are produced by electrogenic transport processes or steady-state ionic currents can be resolved using this method. Because the use of grounded guard electrodes in the end pools is not, by itself, an adequate means of eliminating end-effects, two ancillary end pool clamp circuits are described to eliminate extraneous current flow from the ends of the axon. The end pool voltage-clamp circuits serve to minimize net current flow between the end pools and center pool, and employ stable, low-impedance calomel electrodes to monitor the potentials of the end and center pools. The adequacy of the method is demonstrated by experiments in which unidirectional 22Na efflux and current, flowing through tetrodotoxin (TTX)-sensitive Na channels into Na-free seawater, under K-free conditions, are shown to be equal. The equality of unidirectional TTX-sensitive flux and current is maintained over the entire range of membrane potentials examined (-60 to +20 mV). The method has been applied to a series of experiments in which the voltage dependence and stoichiometry of the Na/K pump have been measured (Rakowski et al., 1989), and can be applied in general to the simultaneous measurement of changes in current and flux of other electrogenic transport processes, and of currents through ionic channels that open under steady-state conditions.




This article has been cited by other articles:


Home page
J. Gen. Physiol.Home page
R.F. Rakowski, P. Artigas, F. Palma, M. Holmgren, P. De Weer, and D. C. Gadsby
Sodium Flux Ratio in Na/K Pump-Channels Opened by Palytoxin
J. Gen. Physiol., July 1, 2007; 130(1): 41 - 54.
[Abstract] [Full Text] [PDF]


Home page
J. Gen. Physiol.Home page
R. F. Rakowski, D. C. Gadsby, and P. De Weer
Single Ion Occupancy and Steady-state Gating of Na Channels in Squid Giant Axon
J. Gen. Physiol., February 22, 2002; 119(3): 235 - 250.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the Biophysical Society.