help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 57: 877-882 (1990)
© 1990 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Katnik, C
Right arrow Articles by Waugh, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Katnik, C
Right arrow Articles by Waugh, R

Alterations of the apparent area expansivity modulus of red blood cell membrane by electric fields.

C Katnik and R Waugh

Department of Biophysics, University of Rochester, School of Medicine and Dentistry, New York 14642.

ABSTRACT

Red blood cell membrane exhibits a large resistance to changes in surface area. This resistance is characterized by the area expansivity modulus K, which relates the isotropic membrane force resultant, T, to the fractional change in membrane surface area delta A/Ao. The experimental technique commonly used to determine K is micropipette aspiration. Using this method, E. A. Evans and R. Waugh (1977, Biophys. J. 20:307-313) obtained a value of 450 dyn/cm for the modulus. In the present report, it is shown that the value of K, as determined using this method, is affected by electric potential differences applied across the tip of the pipette. Using Ag-AgCl electrodes and current clamping electronics, we obtained values for K ranging from 150 dyn/cm with -1.0 V applied, to 1,500 dyn/cm with 1.0 V applied. At 0.0 V the modulus obtained was approximately 500 dyn/cm. A reversible, voltage- and pressure-dependent change in the cell volume probably accounts for the effect of the voltage on the calculated value of the modulus. The use of lanthanum chloride or increasing the extra- and intracellular solute concentrations reduced the voltage dependence of the measurements. It was also found that when dissimilar metals were used to "ground" the pipette to the chamber to prevent lysis of cells by static charge, values for K ranged from 121 to 608 dyn/cm. Based on measurements made at zero applied volts, in the presence of 0.4 mM lanthanum and at high solute concentration, we conclude that the true value of the modulus is approximately 500 dyn/cm.




This article has been cited by other articles:


Home page
Biophys. JHome page
V. Heinrich and C. Ounkomol
Force versus Axial Deflection of Pipette-Aspirated Closed Membranes
Biophys. J., July 15, 2007; 93(2): 363 - 372.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
O. P. Hamill and B. Martinac
Molecular Basis of Mechanotransduction in Living Cells
Physiol Rev, April 1, 2001; 81(2): 685 - 740.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the Biophysical Society.