help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 60: 931-941 (1991)
© 1991 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Copello, J
Right arrow Articles by Reuss, L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Copello, J
Right arrow Articles by Reuss, L

Ba2+ release from soda glass modifies single maxi K+ channel activity in patch clamp experiments.

J Copello, B Simon, Y Segal, F Wehner, V M Ramanujam, N Alcock and L Reuss

Department of Physiology, University of Texas Medical Branch, Galveston 77550.

ABSTRACT

Glasses used to fabricate patch pipettes may release components which affect ion channels (Cota, G., and C.M. Armstrong. 1988. Biophys. J. 53:107-109; Furman, R.E., and J.C. Tanaka. 1988. Biophys. J. 53:287-292; Rojas, L., and C. Zuazaga. 1988. Neurosci. Lett. 88:39-44). The gating properties of maxi K+ channels from Necturus gallbladder epithelium depend on whether borosilicate glass (BG) or blue tip hematocrit glass (SG) is used to construct the patch pipettes. The data are consistent with solubilization from SG of a component which exerts voltage-dependent, cytosolic-side specific block, closely resembling "slow block" by Ba2+ ions. Ringer's solution preincubated with SG, but not with BG, blocked inside-out maxi K+ channels when used as bathing solution. Mass spectrometry revealed that Ba2+ is released by the glass from fast and slow-release compartments (SG contains 3% wt/wt BaO), and is the only ion found in the solution at concentrations consistent with the observed channel block. Additionally, SG released O2-, Na+, Ca2+, and Mg2+, all to micromolar concentrations. These elements do not interfere with maxi K+ channels but they could in principle alter the properties of other ion channels. Thus, screening for channel-modifying substances released by the glass may be necessary for the adequate interpretation of patch-clamp results.