help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 65: 1666-1677 (1993)
© 1993 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Levis, R A
Right arrow Articles by Rae, J L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Levis, R A
Right arrow Articles by Rae, J L

The use of quartz patch pipettes for low noise single channel recording.

R A Levis and J L Rae

Department of Physiology, Rush Medical College, Chicago, Illinois 60612.

ABSTRACT

Quartz has a dissipation factor of approximately 10(-4), which is an order of magnitude less than that of the best glasses previously used to fabricate patch pipettes; it's dielectric constant of 3.8 is also lower than that of other glasses. On the basis of these electrical characteristics it is expected that patch pipettes pulled from quartz tubing will produce significantly less noise than pipettes made from other glasses. Our work confirms these expectations and we describe theoretical and practical aspects of the use of quartz pipettes for single channel patch voltage clamp measurements. Methods for pulling quartz pipettes with a laser-based puller and coating them with low-loss elastomers are discussed, as are precautions that are necessary to achieve low noise recordings. We have shown that quartz pipettes can be pulled from tubing with outer diameter to inner diameter ratios as large as 3 and a method of applying heavy elastomer coatings all the way to the tip of pipettes is presented. Noise sources arising from the pipette and its holder are described theoretically, and it is shown that measured noise is in good agreement with such predictions. With low noise capacitive feedback electronics, small geometry holders, and thick-walled quartz pipettes coated with low-loss elastomers we have been routinely able to achieve noise of 100 fA rms or less in a 5-kHz bandwidth with real cell patches and a pipette immersion depth of approximately 2 mm. On occasion we have achieved noise as low as 60 fA rms in this bandwidth.




This article has been cited by other articles:


Home page
J. Gen. Physiol.Home page
V. V. Cherny, R. Murphy, V. Sokolov, R. A. Levis, and T. E. DeCoursey
Properties of Single Voltage-gated Proton Channels in Human Eosinophils Estimated by Noise Analysis and by Direct Measurement
J. Gen. Physiol., May 27, 2003; 121(6): 615 - 628.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
N. Fertig, R. H. Blick, and J. C. Behrends
Whole Cell Patch Clamp Recording Performed on a Planar Glass Chip
Biophys. J., June 1, 2002; 82(6): 3056 - 3062.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by the Biophysical Society.