help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 66: 2202-2209 (1994)
© 1994 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goetz, D J
Right arrow Articles by Hammer, D A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goetz, D J
Right arrow Articles by Hammer, D A

Dynamics of neutrophil rolling over stimulated endothelium in vitro.

D J Goetz, M E el-Sabban, B U Pauli and D A Hammer

School of Chemical Engineering, Cornell University, Ithaca, New York 14853.

ABSTRACT

Prior to extravasation at sites of acute inflammation, neutrophils roll over activated endothelium. Neutrophil rolling is often characterized by the average rolling velocity. An additional dynamic feature of rolling that has been identified but not extensively studied is the fluctuation in the rolling velocity about the average. To analyze this characteristic further, we have measured the instantaneous velocity of bovine neutrophils interacting with lipopolysaccharide-stimulated bovine aortic endothelium at shear stresses of 1, 2, 3, and 4 dynes/cm2. The average velocities are quantitatively similar to those reported for human neutrophils rolling over reconstituted P-selectin at a surface density of 400 sites/microns 2. At all shear stresses tested, the population average variance in the instantaneous velocity is at least 2 orders of magnitude higher than the theoretical variance generated from experimental error, indicating that the neutrophils translate with a nonconstant velocity. Possible sources of the variance are discussed. These include "macroscopic" sources such as topological heterogeneity in the endothelium and microscopic sources, such as inherent stochastic formation and breakage of the receptor-ligand bonds that mediate the rolling. Regardless of the ultimate source of the variance, these results justify the use of mathematical models that incorporate stochastic processes to describe bond formation and breakage between the neutrophil and the endothelium and hence are able to generate variable velocity trajectories.




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
R. Sumagin and I. H. Sarelius
TNF-{alpha} activation of arterioles and venules alters distribution and levels of ICAM-1 and affects leukocyte-endothelial cell interactions
Am J Physiol Heart Circ Physiol, November 1, 2006; 291(5): H2116 - H2125.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. B. Kim and I. H. Sarelius
Role of shear forces and adhesion molecule distribution on P-selectin-mediated leukocyte rolling in postcapillary venules
Am J Physiol Heart Circ Physiol, December 1, 2004; 287(6): H2705 - H2711.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. B. Abbitt and G. B. Nash
Rheological properties of the blood influencing selectin-mediated adhesion of flowing leukocytes
Am J Physiol Heart Circ Physiol, June 5, 2003; 285(1): H229 - H240.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
S. K. Bhatia, M. R. King, and D. A. Hammer
The State Diagram for Cell Adhesion Mediated by Two Receptors
Biophys. J., April 1, 2003; 84(4): 2671 - 2690.
[Abstract] [Full Text] [PDF]


Home page
BloodHome page
E. E. Burch, V. R. S. Patil, R. T. Camphausen, M. F. Kiani, and D. J. Goetz
The N-terminal peptide of PSGL-1 can mediate adhesion to trauma-activated endothelium via P-selectin in vivo
Blood, June 28, 2002; 100(2): 531 - 538.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
K.-C. Chang, D. F. J. Tees, and D. A. Hammer
The state diagram for cell adhesion under flow: Leukocyte rolling and firm adhesion
PNAS, September 22, 2000; (2000) 200240897.
[Abstract] [Full Text]


Home page
J. Cell Biol.Home page
D. J. Goetz, D. M. Greif, H. Ding, R. T. Camphausen, S. Howes, K. M. Comess, K. R. Snapp, G. S. Kansas, and F. W. Luscinskas
Isolated P-selectin Glycoprotein Ligand-1 Dynamic Adhesion to P- and E-selectin
J. Cell Biol., April 21, 1997; 137(2): 509 - 519.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
E.R. Damiano, J. Westheider, A. Tozeren, and K. Ley
Variation in the Velocity, Deformation, and Adhesion Energy Density of Leukocytes Rolling Within Venules
Circ. Res., December 1, 1996; 79(6): 1122 - 1130.
[Abstract] [Full Text]


Home page
Proc. Natl. Acad. Sci. USAHome page
K.-C. Chang, D. F. J. Tees, and D. A. Hammer
The state diagram for cell adhesion under flow: Leukocyte rolling and firm adhesion
PNAS, October 10, 2000; 97(21): 11262 - 11267.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the Biophysical Society.