help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 71: 2885-2891 (1996)
© 1996 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Omann, G M
Right arrow Articles by Axelrod, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Omann, G M
Right arrow Articles by Axelrod, D

Membrane-proximal calcium transients in stimulated neutrophils detected by total internal reflection fluorescence.

G M Omann and D Axelrod

Department of Surgery, University of Michigan, Ann Arbor 48105, USA. gmomann@umich.edu

ABSTRACT

A novel fluorescence microscope/laser optical system was developed to measure fast transients of membrane-proximal versus bulk cytoplasmic intracellular calcium levels in cells labeled with a fluorescent calcium indicator. The method is based on the rapid chopping of illumination of the cells between optical configurations for epifluorescence, which excites predominantly the bulk intracellular region, and total internal reflection fluorescence, which excites only the region within approximately 100 nm of the cell-substrate contact. This method was applied to Fluo-3-loaded neutrophils that were activated by the chemoattractant N-formyl-met-leu-phe. Chemoattractant-activated cells showed 1) transient increases in both membrane-proximal and bulk cytosolic Ca2+ that peaked simultaneously; 2) a larger fractional change (20-60%) in membrane-proximal Ca2+ relative to bulk cytosolic Ca2+ that peaked at a time when the main Ca2+ transient was decreasing in both regions and that persisted well after the main transient was over. This method should be applicable to a wide variety of cell types and fluorescent ion indicators in which membrane-proximal ionic transients may be different from those deeper within the cytosol.




This article has been cited by other articles:


Home page
J. Neurosci.Home page
D. Zenisek, V. Davila, L. Wan, and W. Almers
Imaging Calcium Entry Sites and Ribbon Structures in Two Presynaptic Cells
J. Neurosci., April 1, 2003; 23(7): 2538 - 2548.