help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 72: 2805-2811 (1997)
© 1997 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gallo, S A
Right arrow Articles by Hui, S W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gallo, S A
Right arrow Articles by Hui, S W

Characterization of electric-pulse-induced permeabilization of porcine skin using surface electrodes.

S A Gallo, A R Oseroff, P G Johnson and S W Hui

Biophysics Department, Roswell Park Cancer Institute, Buffalo, New York 14263, USA.

ABSTRACT

We measured the transient and long-term changes of permeability of full-thickness porcine skin after the application of a single or a train of electric pulses, as the basis for optimization of the electrical parameters for enhancing transdermal drug or gene delivery by electroporation. Two electrodes were attached to the stratum corneum of excised skin for transdermal electric pulse delivery and impedance measurement. Both transient and long-term permeabilization were found to be dependent on the electrical exposure dose, i.e., the product of pulse voltage and cumulative pulsing (exposure) time. Skin resistance dropped to about 20% of its prepulsing value when pulsed beyond a critical dosage of 0.4 V-s (with 20-40 V across each skin path), but recovered rapidly within seconds after the pulse. Long-term permeabilization of the skin required repeated pulsing with a minimum potential of 160 V (80 V across each skin path). The maximum long-term resistance drop, to 35% of the initial value, required a dose greater than 200 V-s, recovering slowly and seldom completely in tens of minutes to hours. The decrease and recovery of the resistance were dependent on the frequency and pulse length only for low-dose electrical exposure.




This article has been cited by other articles:


Home page
Biophys. JHome page
A. Sen, Y.-L. Zhao, and S. W. Hui
Saturated Anionic Phospholipids Enhance Transdermal Transport by Electroporation
Biophys. J., October 1, 2002; 83(4): 2064 - 2073.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the Biophysical Society.