help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Biophysical Journal 73: 452-465 (1997)
© 1997 the Biophysical Society

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Golub, A S
Right arrow Articles by Pittman, R N
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Golub, A S
Right arrow Articles by Pittman, R N

Analysis of phosphorescence in heterogeneous systems using distributions of quencher concentration.

A S Golub, A S Popel, L Zheng and R N Pittman

Department of Physiology, Medical College of Virginia, Virginia Commonwealth University, Richmond 23298-0551, USA.

ABSTRACT

A continuous distribution approach, instead of the traditional mono- and multiexponential analysis, for determining quencher concentration in a heterogeneous system has been developed. A mathematical model of phosphorescence decay inside a volume with homogeneous concentration of phosphor and heterogeneous concentration of quencher was formulated to obtain pulse-response fitting functions for four different distributions of quencher concentration: rectangular, normal (Gaussian), gamma, and multimodal. The analysis was applied to parameter estimates of a heterogeneous distribution of oxygen tension (PO2) within a volume. Simulated phosphorescence decay data were randomly generated for different distributions and heterogeneity of PO2 inside the excitation/emission volume, consisting of 200 domains, and then fit with equations developed for the four models. Analysis using a monoexponential fit yielded a systematic error (underestimate) in mean PO2 that increased with the degree of heterogeneity. The fitting procedures based on the continuous distribution approach returned more accurate values for parameters of the generated PO2 distribution than did the monoexponential fit. The parameters of the fit (M = mean; sigma = standard deviation) were investigated as a function of signal-to-noise ratio (SNR = maximum signal amplitude/peak-to-peak noise). The best-fit parameter values were stable when SNR > or = 20. All four fitting models returned accurate values of M and sigma for different PO2 distributions. The ability of our procedures to resolve two different heterogeneous compartments was also demonstrated using a bimodal fitting model. An approximate scheme was formulated to allow calculation of the first moments of a spatial distribution of quencher without specifying the distribution. In addition, a procedure for the recovery of a histogram, representing the quencher concentration distribution, was developed and successfully tested.




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. S. Golub and R. N. Pittman
PO2 measurements in the microcirculation using phosphorescence quenching microscopy at high magnification
Am J Physiol Heart Circ Physiol, June 1, 2008; 294(6): H2905 - H2916.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. S. Golub, M. C. Barker, and R. N. Pittman
Microvascular oxygen tension in the rat mesentery
Am J Physiol Heart Circ Physiol, January 1, 2008; 294(1): H21 - H28.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Shibata, K. Qin, S. Ichioka, and A. Kamiya
Vascular wall energetics in arterioles during nitric oxide-dependent and -independent vasodilation
J Appl Physiol, June 1, 2006; 100(6): 1793 - 1798.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. Johannes, E. G. Mik, and C. Ince
Dual-wavelength phosphorimetry for determination of cortical and subcortical microvascular oxygenation in rat kidney
J Appl Physiol, April 1, 2006; 100(4): 1301 - 1310.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Shibata, S. Ichioka, and A. Kamiya
Nitric oxide modulates oxygen consumption by arteriolar walls in rat skeletal muscle
Am J Physiol Heart Circ Physiol, December 1, 2005; 289(6): H2673 - H2679.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Shibata, S. Ichioka, and A. Kamiya
Estimating oxygen consumption rates of arteriolar walls under physiological conditions in rat skeletal muscle
Am J Physiol Heart Circ Physiol, July 1, 2005; 289(1): H295 - H300.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. S. Golub and R. N. Pittman
Erythrocyte-associated transients in PO2 revealed in capillaries of rat mesentery
Am J Physiol Heart Circ Physiol, June 1, 2005; 288(6): H2735 - H2743.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
E. G. Mik, T. G. van Leeuwen, N. J. Raat, and C. Ince
Quantitative determination of localized tissue oxygen concentration in vivo by two-photon excitation phosphorescence lifetime measurements
J Appl Physiol, November 1, 2004; 97(5): 1962 - 1969.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Shibata, S. Ichioka, J. Ando, and A. Kamiya
Microvascular and interstitial PO2 measurements in rat skeletal muscle by phosphorescence quenching
J Appl Physiol, July 1, 2001; 91(1): 321 - 327.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. Vadapalli, R. N. Pittman, and A. S. Popel
Estimating oxygen transport resistance of the microvascular wall
Am J Physiol Heart Circ Physiol, August 1, 2000; 279(2): H657 - H671.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the Biophysical Society.