| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Department of Chemical Sciences, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005, India
Correspondence: Address reprint requests to N. Periasamy or S. Maiti, E-mail: peri{at}tifr.res.in or maiti{at}tifr.res.in.
Fluorescence correlation spectroscopy (FCS) is a sensitive and widely used technique for measuring diffusion. FCS data are conventionally modeled with a finite number of diffusing components and fit with a least-square fitting algorithm. This approach is inadequate for analyzing data obtained from highly heterogeneous systems. We introduce a Maximum Entropy Method based fitting routine (MEMFCS) that analyzes FCS data in terms of a quasicontinuous distribution of diffusing components, and also guarantees a maximally wide distribution that is consistent with the data. We verify that for a homogeneous specimen (green fluorescent protein in dilute aqueous solution), both MEMFCS and conventional fitting yield similar results. Further, we incorporate an appropriate goodness of fit criterion in MEMFCS. We show that for errors estimated from a large number of repeated measurements, the reduced
2 value in MEMFCS analysis does approach unity. We find that the theoretical prediction for errors in FCS experiments overestimates the actual error, but can be empirically modified to serve as a guide for estimating the goodness of the fit where reliable error estimates are unavailable. Finally, we compare the performance of MEMFCS with that of a conventional fitting routine for analyzing simulated data describing a highly heterogeneous distribution containing 41 diffusing species. Both methods fit the data well. However, the conventional fit fails to reproduce the essential features of the input distribution, whereas MEMFCS yields a distribution close to the actual input.
This article has been cited by other articles:
![]() |
A. B. Goins, H. Sanabria, and M. N. Waxham Macromolecular Crowding and Size Effects on Probe Microviscosity Biophys. J., December 1, 2008; 95(11): 5362 - 5373. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. J. H. Koopman, F. Distelmaier, M. A. Hink, S. Verkaart, M. Wijers, J. Fransen, J. A. M. Smeitink, and P. H. G. M. Willems Inherited complex I deficiency is associated with faster protein diffusion in the matrix of moving mitochondria Am J Physiol Cell Physiol, May 1, 2008; 294(5): C1124 - C1132. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Garai, R. Sureka, and S. Maiti Detecting Amyloid-{beta} Aggregation with Fiber-Based Fluorescence Correlation Spectroscopy Biophys. J., April 1, 2007; 92(7): L55 - L57. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Saxton A Biological Interpretation of Transient Anomalous Subdiffusion. I. Qualitative Model Biophys. J., February 15, 2007; 92(4): 1178 - 1191. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Sanabria, Y. Kubota, and M. N. Waxham Multiple Diffusion Mechanisms Due to Nanostructuring in Crowded Environments Biophys. J., January 1, 2007; 92(1): 313 - 322. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Banks and C. Fradin Anomalous Diffusion of Proteins Due to Molecular Crowding Biophys. J., November 1, 2005; 89(5): 2960 - 2971. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Fatin-Rouge, K. Starchev, and J. Buffle Size Effects on Diffusion Processes within Agarose Gels Biophys. J., May 1, 2004; 86(5): 2710 - 2719. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |