help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ober, R. J.
Right arrow Articles by Ward, E. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ober, R. J.
Right arrow Articles by Ward, E. S.
Biophysical Journal 86:1185-1200 (2004)
© 2004 The Biophysical Society

Localization Accuracy in Single-Molecule Microscopy

Raimund J. Ober * {dagger}, Sripad Ram {ddagger} § and E. Sally Ward {dagger} {ddagger}

* Department of Electrical Engineering, University of Texas at Dallas, Richardson, Texas; {dagger} Cancer Immunobiology Center and {ddagger} Center for Immunology, University of Texas Southwestern Medical Center, Dallas, Texas; and § Joint Biomedical Engineering Graduate Program, University of Texas at Arlington/University of Texas Southwestern Medical Center, Dallas, Texas

Correspondence: Address reprint requests to Raimund J. Ober, E-mail: ober{at}utdallas.edu.

One of the most basic questions in single-molecule microscopy concerns the accuracy with which the location of a single molecule can be determined. Using the Fisher information matrix it is shown that the limit of the localization accuracy for a single molecule is given by , where {lambda}em, na, {gamma}, A, and t denote the emission wavelength of the single molecule, the numerical aperture of the objective, the efficiency of the optical system, the emission rate of the single molecule and the acquisition time, respectively. Using Monte Carlo simulations it is shown that estimation algorithms can come close to attaining the limit given in the expression. Explicit quantitative results are also provided to show how the limit of the localization accuracy is reduced by factors such as pixelation of the detector and noise sources in the detection system. The results demonstrate what is achievable by single-molecule microscopy and provide guidelines for experimental design.




This article has been cited by other articles:


Home page
JCBHome page
T. Dange, D. Grunwald, A. Grunwald, R. Peters, and U. Kubitscheck
Autonomy and robustness of translocation through the nuclear pore complex: a single-molecule study
J. Cell Biol., October 6, 2008; 183(1): 77 - 86.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
X. Michalet and S. Weiss
Using photon statistics to boost microscopy resolution
PNAS, March 28, 2006; 103(13): 4797 - 4798.
[Full Text] [PDF]


Home page
Biophys. JHome page
L. P. Watkins and H. Yang
Information Bounds and Optimal Analysis of Dynamic Single Molecule Measurements
Biophys. J., June 1, 2004; 86(6): 4015 - 4029.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the Biophysical Society.