| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |



* M. E. Müller Institute for Structural Biology, Biozentrum University of Basel, Switzerland;
Department of Biophysical and Electronic Engineering, University of Genoa, Genoa, Italy;
Laboratory for Orthopedic Biomechanics, Felix Platter Hospital, University of Basel, Switzerland;
Army Research Laboratory, Aberdeen Proving Ground, Aberdeen, Maryland USA; ¶ Department of Oral Surgery, University of Basel, Switzerland
Correspondence: Address reprint requests to Ueli Aebi, M. E. Müller Institute for Structural Biology, Biozentrum University of Basel, Klingelberstraße 70, Basel CH-4056, Switzerland. Tel.: +41-61-267 2260; Fax.: 41-61-267 2109; E-mail: ueli.aebi{at}unibas.ch.
Cartilage stiffness was measured ex vivo at the micrometer and nanometer scales to explore structure-mechanical property relationships at smaller scales than has been done previously. A method was developed to measure the dynamic elastic modulus, |E*|, in compression by indentation-type atomic force microscopy (IT AFM). Spherical indenter tips (radius =
2.5 µm) and sharp pyramidal tips (radius =
20 nm) were employed to probe micrometer-scale and nanometer-scale response, respectively. |E*| values were obtained at 3 Hz from 1024 unloading response curves recorded at a given location on subsurface cartilage from porcine femoral condyles. With the microsphere tips, the average modulus was
2.6 MPa, in agreement with available millimeter-scale data, whereas with the sharp pyramidal tips, it was typically 100-fold lower. In contrast to cartilage, measurements made on agarose gels, a much more molecularly amorphous biomaterial, resulted in the same average modulus for both indentation tips. From results of AFM imaging of cartilage, the micrometer-scale spherical tips resolved no fine structure except some chondrocytes, whereas the nanometer-scale pyramidal tips resolved individual collagen fibers and their 67-nm axial repeat distance. These results suggest that the spherical AFM tip is large enough to measure the aggregate dynamic elastic modulus of cartilage, whereas the sharp AFM tip depicts the elastic properties of its fine structure. Additional measurements of cartilage stiffness following enzyme action revealed that elastase digestion of the collagen moiety lowered the modulus at the micrometer scale. In contrast, digestion of the proteoglycans moiety by cathepsin D had little effect on |E*| at the micrometer scale, but yielded a clear stiffening at the nanometer scale. Thus, cartilage compressive stiffness is different at the nanometer scale compared to the overall structural stiffness measured at the micrometer and larger scales because of the fine nanometer-scale structure, and enzyme-induced structural changes can affect this scale-dependent stiffness differently.
This article has been cited by other articles:
![]() |
M. P. E. Wenger, L. Bozec, M. A. Horton, and P. Mesquida Mechanical Properties of Collagen Fibrils Biophys. J., August 15, 2007; 93(4): 1255 - 1263. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Han, D. Dean, C. Ortiz, and A. J. Grodzinsky Lateral Nanomechanics of Cartilage Aggrecan Macromolecules Biophys. J., February 15, 2007; 92(4): 1384 - 1398. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Gueta, D. Barlam, R. Z. Shneck, and I. Rousso Measurement of the mechanical properties of isolated tectorial membrane using atomic force microscopy PNAS, October 3, 2006; 103(40): 14790 - 14795. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Kol, M. Gladnikoff, D. Barlam, R. Z. Shneck, A. Rein, and I. Rousso Mechanical Properties of Murine Leukemia Virus Particles: Effect of Maturation Biophys. J., July 15, 2006; 91(2): 767 - 774. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Tanaka, E. Yamano, D.A. Dalla-Bona, M. Watanabe, T. Inubushi, M. Shirakura, R. Sano, K. Takahashi, T. van Eijden, and K. Tanne Dynamic compressive properties of the mandibular condylar cartilage. J. Dent. Res., June 1, 2006; 85(6): 571 - 575. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Shoelson, E. K. Dimitriadis, H. Cai, B. Kachar, and R. S. Chadwick Evidence and Implications of Inhomogeneity in Tectorial Membrane Elasticity Biophys. J., October 1, 2004; 87(4): 2768 - 2777. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |