help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pierrat, S.
Right arrow Articles by Nassoy, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pierrat, S.
Right arrow Articles by Nassoy, P.
Biophysical Journal 87:2855-2869 (2004)
© 2004 The Biophysical Society

Enforced Detachment of Red Blood Cells Adhering to Surfaces: Statics and Dynamics

Sébastien Pierrat, Françoise Brochard-Wyart and Pierre Nassoy

Laboratoire de Physico-Chimie Curie, Unité Mixte de Recherche 168, Centre National de la Recherche Scientifique, Institut Curie, Paris, France

Correspondence: Address reprint requests to Dr. P. Nassoy, E-mail: pierre.nassoy{at}curie.fr.

We investigated the mechanical strength of adhesion and the dynamics of unbinding of red blood cells to solid surfaces. Two different situations were tested: 1), native red blood cells nonspecifically adhered to glass surfaces coated with positively charged polymers and 2), biotinylated red blood cells specifically adhered to glass surfaces decorated with streptavidin, which has a high binding affinity for biotin. We used micropipette manipulation for forming and subsequently breaking the adhesive contact through a stepwise micromechanical procedure. Analysis of cell deformations provided the relation between force and contact radius, which was found to be in good agreement with theoretical predictions. We further demonstrated that the separation energy could be precisely derived from the measure of rupture forces and the cell shape. Finally, the dynamics of detachment was analyzed as a function of the applied force and the initial size of the adhesive patch. Our experiments were supported by original theoretical predictions, which allowed us to correlate the measured separation times with the molecular parameters (e.g., activation barrier, receptor-ligand characteristic length) derived from force measurements at the single bond level.




This article has been cited by other articles:


Home page
Biophys. JHome page
V. Heinrich and C. Ounkomol
Force versus Axial Deflection of Pipette-Aspirated Closed Membranes
Biophys. J., July 15, 2007; 93(2): 363 - 372.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
S. Sen, S. Subramanian, and D. E. Discher
Indentation and Adhesive Probing of a Cell Membrane with AFM: Theoretical Model and Experiments
Biophys. J., November 1, 2005; 89(5): 3203 - 3213.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the Biophysical Society.