help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on August 5, 2005.
doi:10.1529/biophysj.105.066738
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow supplemental
Right arrow All Versions of this Article:
biophysj.105.066738v1
89/4/2759    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ajo-Franklin, C. M.
Right arrow Articles by Boxer, S. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ajo-Franklin, C. M.
Right arrow Articles by Boxer, S. G.
Biophysical Journal 89:2759-2769 (2005)
© 2005 The Biophysical Society

Variable Incidence Angle Fluorescence Interference Contrast Microscopy for Z-Imaging Single Objects

Caroline M. Ajo-Franklin, Prasad V. Ganesan and Steven G. Boxer

Department of Chemistry, Stanford University, Stanford, California 94305-5080

Correspondence: Address reprint requests to Steven G. Boxer, Tel.: 650-723-4482; Fax: (650) 723-4817; E-mail: sboxer{at}stanford.edu.

Surface-generated structured illumination microscopies interrogate the position of fluorescently labeled objects near surfaces with nanometer resolution along the z axis. However, these techniques are either experimentally cumbersome or applicable to a limited set of experimental systems. We present a new type of surface-generated structured illumination fluorescence microscopy, variable incidence angle fluorescence interference contrast microscopy (VIA-FLIC), in which the fluorescent sample is assembled above a reflective Si surface and the incidence angle of excitation light is varied by placing annular photomasks with different radii in the aperture diaphragm plane of the microscope. The variation in incidence angle alters the interference pattern of excitation light, and hence the intensity of detected fluorescence. Quantitative VIA-FLIC is tested by using a set of fluorophore-containing supported membranes separated from the Si surface by SiO2 layers of variable thicknesses. The resulting fluorescence intensity versus incidence angle curves depends on the separation from the Si surface and when fit with an appropriate model yield precise SiO2 thicknesses that are accurate with respect to the known SiO2 thicknesses. Since only a simple modification to a standard epifluorescence microscope is required, VIA-FLIC offers a versatile method to produce z-reconstructions with high resolution for a wide range of biological systems.




This article has been cited by other articles:


Home page
Biophys. JHome page
M. C. Howland, A. W. Szmodis, B. Sanii, and A. N. Parikh
Characterization of Physical Properties of Supported Phospholipid Membranes Using Imaging Ellipsometry at Optical Wavelengths
Biophys. J., February 15, 2007; 92(4): 1306 - 1317.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the Biophysical Society.