help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on August 12, 2005.
doi:10.1529/biophysj.105.066134
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
biophysj.105.066134v1
89/5/3603    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Edmondson, K. E.
Right arrow Articles by Diamond, S. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Edmondson, K. E.
Right arrow Articles by Diamond, S. L.
Biophysical Journal 89:3603-3614 (2005)
© 2005 The Biophysical Society

Neutrophil-Bead Collision Assay: Pharmacologically Induced Changes in Membrane Mechanics Regulate the PSGL-1/P-Selectin Adhesion Lifetime

K. E. Edmondson * {dagger}, W. S. Denney * {ddagger} and S. L. Diamond * {dagger} {ddagger}

* Institute for Medicine and Engineering, {dagger} Department of Bioengineering, and {ddagger} Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, Pennsylvania

Correspondence: Address reprint requests to S. L. Diamond, Tel.: 215-573-5702; E-mail: sld{at}seas.upenn.edu.

Visualization of flowing neutrophils colliding with adherent 1-µm-diameter beads presenting P-selectin allowed the simultaneous measurement of collision efficiency ({varepsilon}), membrane tethering fraction (f), membrane tether growth dynamics, and PSGL-1/P-selectin binding lifetime. For 1391 collisions analyzed over venous wall shear rates from 25 to 200 s–1, {varepsilon} decreased from 0.17 to 0.004, whereas f increased from 0.15 to 0.70, and the average projected membrane tether length, increased from 0.35 µm to ~2.0 µm over this shear range. At all shear rates tested, adhesive collisions lacking membrane tethers had average bond lifetimes less than those observed for collisions with tethers. For adhesive collisions that failed to form membrane tethers, the regressed Bell parameters (consistent with single bond Monte Carlo simulation) were zero-stress off-rate, koff(0) = 0.56 s–1 and reactive compliance, r = 0.10 nm, similar to published atomic force microscopy (AFM) measurements. For all adhesion events (± tethers), the bond lifetime distributions were more similar to those obtained by rolling assay and best simulated by Monte Carlo with the above Bell parameters and an average of 1.48 bonds (n = 1 bond (67%), n = 2 (22%), and n = 3–5 (11%)). For collisions at 100 s–1, pretreatment of neutrophils with actin depolymerizing agents, latrunculin or cytochalasin D, had no effect on {varepsilon}, but increased by 1.74- or 2.65-fold and prolonged the average tether lifetime by 1.41- or 1.65-fold, respectively. Jasplakinolide, an actin polymerizing agent known to cause blebbing, yielded results similar to the depolymerizing agents. Conversely, cholesterol-depletion with methyl-ß-cyclodextrin or formaldehyde fixation had no effect on {varepsilon}, but reduced by 66% or 97% and reduced the average tether lifetime by 30% or 42%, respectively. The neutrophil-bead collision assay combines advantages of atomic force microscopy (small contact zone), aggregometry (discrete interactions), micropipette manipulation (tether visualization), and rolling assays (physiologic flow loading). Membrane tether growth can be enhanced or reduced pharmacologically with consequent effects on PSGL-1/P-selectin lifetimes.




This article has been cited by other articles:


Home page
J. Immunol.Home page
H. Oh and S. L. Diamond
Ethanol Enhances Neutrophil Membrane Tether Growth and Slows Rolling on P-Selectin but Reduces Capture from Flow and Firm Arrest on IL-1-Treated Endothelium
J. Immunol., August 15, 2008; 181(4): 2472 - 2482.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
U. M. Okorie and S. L. Diamond
Matrix Protein Microarrays for Spatially and Compositionally Controlled Microspot Thrombosis under Laminar Flow
Biophys. J., November 1, 2006; 91(9): 3474 - 3481.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the Biophysical Society.