| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||



* Institute for Medicine and Engineering,
Department of Bioengineering, and
Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, Pennsylvania
Correspondence: Address reprint requests to S. L. Diamond, Tel.: 215-573-5702; E-mail: sld{at}seas.upenn.edu.
Visualization of flowing neutrophils colliding with adherent 1-µm-diameter beads presenting P-selectin allowed the simultaneous measurement of collision efficiency (
), membrane tethering fraction (f), membrane tether growth dynamics, and PSGL-1/P-selectin binding lifetime. For 1391 collisions analyzed over venous wall shear rates from 25 to 200 s1,
decreased from 0.17 to 0.004, whereas f increased from 0.15 to 0.70, and the average projected membrane tether length,
increased from 0.35 µm to
2.0 µm over this shear range. At all shear rates tested, adhesive collisions lacking membrane tethers had average bond lifetimes less than those observed for collisions with tethers. For adhesive collisions that failed to form membrane tethers, the regressed Bell parameters (consistent with single bond Monte Carlo simulation) were zero-stress off-rate, koff(0) = 0.56 s1 and reactive compliance, r = 0.10 nm, similar to published atomic force microscopy (AFM) measurements. For all adhesion events (± tethers), the bond lifetime distributions were more similar to those obtained by rolling assay and best simulated by Monte Carlo with the above Bell parameters and an average of 1.48 bonds (n = 1 bond (67%), n = 2 (22%), and n = 35 (11%)). For collisions at 100 s1, pretreatment of neutrophils with actin depolymerizing agents, latrunculin or cytochalasin D, had no effect on
, but increased
by 1.74- or 2.65-fold and prolonged the average tether lifetime by 1.41- or 1.65-fold, respectively. Jasplakinolide, an actin polymerizing agent known to cause blebbing, yielded results similar to the depolymerizing agents. Conversely, cholesterol-depletion with methyl-ß-cyclodextrin or formaldehyde fixation had no effect on
, but reduced
by 66% or 97% and reduced the average tether lifetime by 30% or 42%, respectively. The neutrophil-bead collision assay combines advantages of atomic force microscopy (small contact zone), aggregometry (discrete interactions), micropipette manipulation (tether visualization), and rolling assays (physiologic flow loading). Membrane tether growth can be enhanced or reduced pharmacologically with consequent effects on PSGL-1/P-selectin lifetimes.
This article has been cited by other articles:
![]() |
H. Oh and S. L. Diamond Ethanol Enhances Neutrophil Membrane Tether Growth and Slows Rolling on P-Selectin but Reduces Capture from Flow and Firm Arrest on IL-1-Treated Endothelium J. Immunol., August 15, 2008; 181(4): 2472 - 2482. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. M. Okorie and S. L. Diamond Matrix Protein Microarrays for Spatially and Compositionally Controlled Microspot Thrombosis under Laminar Flow Biophys. J., November 1, 2006; 91(9): 3474 - 3481. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |