help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on February 26, 2007.
doi:10.1529/biophysj.107.104901
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
biophysj.107.104901v1
92/9/L76    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ke, C.
Right arrow Articles by Marszalek, P. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ke, C.
Right arrow Articles by Marszalek, P. E.
Biophysical Journal 92:L76-L78 (2007)
© 2007 The Biophysical Society

Pulling Geometry-Induced Errors in Single Molecule Force Spectroscopy Measurements

Changhong Ke, Yong Jiang, Monica Rivera, Robert L. Clark and Piotr E. Marszalek

Department of Mechanical Engineering and Materials Science, Center For Biologically Inspired Materials and Material Systems, Pratt School of Engineering, Duke University, Durham, North Carolina

Correspondence: Address reprint requests and inquiries to Dr. Piotr E. Marszalek, E-mail: pemar{at}duke.edu.

In AFM-based single molecule force spectroscopy, it is tacitly assumed that the pulling direction coincides with the end-to-end vector of the molecule fragment being stretched. By systematically varying the position of the attachment point on the substrate relative to the AFM tip, we investigate empirically and theoretically the effect of the pulling geometry on force-extension characteristics of double-stranded DNA. We find that increasing the pulling angle can significantly lower the force of the characteristic overstretching transition and increase the width of the plateau feature beyond the canonical 70%. These effects, when neglected, can adversely affect the interpretation of measured force-extension relationships. We quantitatively evaluate force and extension errors originating from this "pulling angle effect" and stress the need to correct the pulling geometry when stretching rigid molecules with an AFM.




This article has been cited by other articles:


Home page
Biophys. JHome page
Y. Seol, J. Li, P. C. Nelson, T. T. Perkins, and M. D. Betterton
Elasticity of Short DNA Molecules: Theory and Experiment for Contour Lengths of 0.6 7 {micro}m
Biophys. J., December 15, 2007; 93(12): 4360 - 4373.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the Biophysical Society.