help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on September 7, 2007.
doi:10.1529/biophysj.107.110601
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplement
Right arrow All Versions of this Article:
biophysj.107.110601v1
94/1/306    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Carter, B. C.
Right arrow Articles by Gross, S. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Carter, B. C.
Right arrow Articles by Gross, S. P.
Biophysical Journal 94:306-319 (2008)
© 2008 The Biophysical Society

A Comparison of Step-Detection Methods: How Well Can You Do?

Brian C. Carter *, Michael Vershinin {dagger} and Steven P. Gross * {dagger}

* Department of Physics, {dagger} Department of Developmental and Cell Biology, University of California-Irvine, Irvine, California

Correspondence: Address reprint requests to S. P. Gross, E-mail: sgross{at}uci.edu.

Many biological machines function in discrete steps, and detection of such steps can provide insight into the machines' dynamics. It is therefore crucial to develop an automated method to detect steps, and determine how its success is impaired by the significant noise usually present. A number of step detection methods have been used in previous studies, but their robustness and relative success rate have not been evaluated. Here, we compare the performance of four step detection methods on artificial benchmark data (simulating different data acquisition and stepping rates, as well as varying amounts of Gaussian noise). For each of the methods we investigate how to optimize performance both via parameter selection and via prefiltering of the data. While our analysis reveals that many of the tested methods have similar performance when optimized, we find that the method based on a chi-squared optimization procedure is simplest to optimize, and has excellent temporal resolution. Finally, we apply these step detection methods to the question of observed step sizes for cargoes moved by multiple kinesin motors in vitro. We conclude there is strong evidence for sub-8-nm steps of the cargo's center of mass in our multiple motor records.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Biophysical Society.