help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on March 13, 2008.
doi:10.1529/biophysj.106.103218
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
biophysj.106.103218v1
94/12/5018    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Kennedy, S. M.
Right arrow Articles by Hagness, S. C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kennedy, S. M.
Right arrow Articles by Hagness, S. C.
Biophysical Journal 94:5018-5027 (2008)
© 2008 The Biophysical Society

Quantification of Electroporative Uptake Kinetics and Electric Field Heterogeneity Effects in Cells

S. M. Kennedy, Z. Ji, J. C. Hedstrom, J. H. Booske and S. C. Hagness

Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin 53706

Correspondence: Address reprint requests to S. M. Kennedy, E-mail: smkennedy{at}wisc.edu.

We have conducted experiments quantitatively investigating electroporative uptake kinetics of a fluorescent plasma membrane integrity indicator, propidium iodide (PI), in HL60 human leukemia cells resulting from exposure to 40 µs pulsed electric fields (PEFs). These experiments were possible through the use of calibrated, real-time fluorescence microscopy and the development of a microcuvette: a specialized device designed for exposing cell cultures to intense PEFs while carrying out real-time microscopy. A finite-element electrostatic simulation was carried out to assess the degree of electric field heterogeneity between the microcuvette's electrodes allowing us to correlate trends in electroporative response to electric field distribution. Analysis of experimental data identified two distinctive electroporative uptake signatures: one characterized by low-level, decelerating uptake beginning immediately after PEF exposure and the other by high-level, accelerating fluorescence that is manifested sometimes hundreds of seconds after PEF exposure. The qualitative nature of these fluorescence signatures was used to isolate the conditions required to induce exclusively transient electroporation and to discuss electropore stability and persistence. A range of electric field strengths resulting in transient electroporation was identified for HL60s under our experimental conditions existing between 1.6 and 2 kV/cm. Quantitative analysis was used to determine that HL60s experiencing transient electroporation internalized between 50 and 125 million nucleic acid-bound PI molecules per cell. Finally, we show that electric field heterogeneity may be used to elicit asymmetric electroporative PI uptake within cell cultures and within individual cells.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Biophysical Society.