help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on September 21, 2007.
doi:10.1529/biophysj.106.098707
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplement
Right arrow All Versions of this Article:
biophysj.106.098707v1
94/3/1034    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Paschall, C. D.
Right arrow Articles by Lawrence, M. B.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Paschall, C. D.
Right arrow Articles by Lawrence, M. B.
Biophysical Journal 94:1034-1045 (2008)
© 2008 The Biophysical Society

Enhancement of L-Selectin, but Not P-Selectin, Bond Formation Frequency by Convective Flow

Christopher D. Paschall, William H. Guilford and Michael B. Lawrence

Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia 22908

Correspondence: Address reprint requests to William H. Guilford, Dept. of Biomedical Engineering, PO Box 800759, MR5, 1111 415 Lane Road, University of Virginia, Charlottesville, VA 22908. Tel.: 434-924-9908; Fax: 434-982-3870; E-mail: whg2n{at}virginia.edu.

L-selectin-mediated leukocyte rolling has been proposed to require a high rate of bond formation compared to that of P-selectin to compensate for its much higher off-rate. To test this hypothesis, a microbead system was utilized to measure relative L-selectin and P-selectin bond formation rates on their common ligand P-selectin glycoprotein ligand-1 (PSGL-1) under shear flow. Using video microscopy, we tracked selectin-coated microbeads to detect the formation frequency of adhesive tether bonds. From velocity distributions of noninteracting and interacting microbeads, we observed that tether bond formation rates for P-selectin on PSGL-1 decreased with increasing wall shear stress, from 0.14 ± 0.04 bonds/µm at 0.2 dyn/cm2 to 0.014 ± 0.003 bonds/µm at 1.0 dyn/cm2. In contrast, L-selectin tether bond formation increased from 0.017 ± 0.005 bonds/µm at 0.2 dyn/cm2 to 0.031 ± 0.005 bonds/µm at 1.0 dyn/cm2. L-selectin tether bond formation rates appeared to be enhanced by convective transport, whereas P-selectin rates were inhibited. The transition force for the L-selectin catch-slip transition of 44 pN/bond agreed well with theoretical models (Pereverzev et al. 2005. Biophys. J. 89:1446-1454). Despite catch bond behavior, hydrodymanic shear thresholding was not detected with L-selectin beads rolling on PSGL-1. We speculate that shear flow generated compressive forces may enhance L-selectin bond formation relative to that of P-selectin and that L-selectin bonds with PSGL-1 may be tuned for the compressive forces characteristic of leukocyte-leukocyte collisions during secondary capture on the blood vessel wall. This is the first report, to our knowledge, comparing L-selectin and P-selectin bond formation frequencies in shear flow.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Biophysical Society.