help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on October 12, 2007.
doi:10.1529/biophysj.107.108811
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplement
Right arrow All Versions of this Article:
biophysj.107.108811v1
94/4/1437    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Petrásek, Z.
Right arrow Articles by Schwille, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Petrásek, Z.
Right arrow Articles by Schwille, P.
Biophysical Journal 94:1437-1448 (2008)
© 2008 The Biophysical Society

Precise Measurement of Diffusion Coefficients using Scanning Fluorescence Correlation Spectroscopy

Zdenek Petrásek and Petra Schwille

Biophysics Group, Biotechnologisches Zentrum, Technische Universität Dresden, Dresden, Germany

Correspondence: Address reprint requests to Dr. Zdenek Petrásek, Tel.: 49-(0)351-463-40323; E-mail: zdenek.petrasek{at}biotec.tu-dresden.de.

We have implemented scanning fluorescence correlation spectroscopy (sFCS) for precise determination of diffusion coefficients of fluorescent molecules in solution. The measurement volume where the molecules are excited, and from which the fluorescence is detected, was scanned in a circle with radius comparable to its size at frequencies 0.5–2 kHz. The scan radius R, determined with high accuracy by careful calibration, provides the spatial measure required for the determination of the diffusion coefficient D, without the need to know the exact size of the measurement volume. The difficulties in the determination of the measurement volume size have limited the application of standard FCS with fixed measurement volume to relative measurements, where the diffusion coefficient is determined by comparison with a standard. We demonstrate, on examples of several common fluorescent dyes, that sFCS can be used to measure D with high precision without a need for a standard. The correct value of D can be determined in the presence of weak photobleaching, and when the measurement volume size is modified, indicating the robustness of the method. The applicability of the presented implementation of sFCS to biological systems in demonstrated on the measurement of the diffusion coefficient of eGFP in the cytoplasm of HeLa cells. With the help of simulations, we find the optimal value of the scan radius R for the experiment.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Biophysical Society.