help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on November 9, 2007.
doi:10.1529/biophysj.107.117234
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplement
Right arrow All Versions of this Article:
biophysj.107.117234v1
biophysj.107.117234v2
94/6/2333    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Saffarian, S.
Right arrow Articles by Kirchhausen, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Saffarian, S.
Right arrow Articles by Kirchhausen, T.
Biophysical Journal 94:2333-2342 (2008)
© 2008 The Biophysical Society

Differential Evanescence Nanometry: Live-Cell Fluorescence Measurements with 10-nm Axial Resolution on the Plasma Membrane

Saveez Saffarian and Tomas Kirchhausen

Department of Cell Biology and Immune Disease Institute, Harvard Medical School, Boston, Massachusetts

Correspondence: Address reprint requests to Tomas Kirchhausen, Dept. of Cell Biology and Immune Disease Institute, Harvard Medical School, 200 Longwood Ave., Boston, MA 02115. Tel.: 617-278-3140; Fax: 617-278-3125. E-mail: Kirchhausen{at}crystal.harvard.edu.

We present a method to resolve components within a diffraction-limited object by tracking simultaneously the average axial positions of two different sets of fluorescent molecules within it. The axial positions are then subtracted from each other to determine the separation of the two sets of fluorophores. This method follows the dynamic changes in the separation of the two sets of fluorophores with freely rotating dipoles using sequential acquisitions with total internal reflection and wide-field illumination, and it can be used to measure the formation of small structures on living cells. We have verified that we can achieve a resolution of 10 nm, and we have used the method to follow the location of clathrin and its adaptor AP-2 as they are recruited to a diffraction-limited coated pit during its assembly at the plasma membrane. We find a gradually increasing axial separation between the centroids of clathrin and AP-2 distribution, up to a final value of 30 nm just before coated-pit pinching and formation of the coated vesicle.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Biophysical Society.