help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH

Biophys. J. BioFAST: First Published August 12, 2005. doi:10.1529/biophysj.105.066134
© 2005 by the Biophysical Society.


A more recent version of this article appeared on November 1, 2005.
This Article
Right arrow Full Text (Rapid PDF)
Right arrow All Versions of this Article:
biophysj.105.066134v1
89/5/3603    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Edmondson, K. E.
Right arrow Articles by Diamond, S. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Edmondson, K. E.
Right arrow Articles by Diamond, S. L.

CELL BIOPHYSICS

Neutrophil-bead collision assay: Pharmacologically-induced changes in membrane mechanics regulate the PSGL-1/P-selectin adhesion lifetime

Kathryn E. Edmondson 1, William S. Denney 1 and Scott L. Diamond 2*

1 University of Pennsylvania
2 University of Pennsylvania IME

* To whom correspondence should be addressed. E-mail: sld{at}seas.upenn.edu.

Submitted on May 10, 2005
Revised on July 16, 2005
Accepted on 3 August 2005


   Abstract
Visualization of flowing neutrophils colliding with adherent 1-micron diameter beads presenting P-selectin allowed the simultaneous measurement of collision efficiency ({epsilon}), membrane tethering fraction (f), membrane tether growth dynamics, and PSGL-1/P-selectin binding lifetime. For 1391 collisions analyzed over venous wall shear rates from 25 to 200 sec-1, {epsilon} decreased from 0.17 to 0.004, while f increased from 0.15 to 0.70, and the average projected membrane tether length, Lmtether, increased from 0.35 µm to ~2.0 µm over this shear range. At all shear rates tested, adhesive collisions lacking membrane tethers had average bond lifetimes less than those observed for collisions with tethers. For adhesive collisions that failed to form membrane tethers, the regressed Bell parameters (consistent with single bond Monte Carlo simulation) were: zero-stress off-rate, koff(0) = 0.56 sec-1 and reactive compliance, r = 0.10 nm, similar to published AFM measurements. For all adhesion events (± tethers), the bond lifetime distributions were more similar to those obtained by rolling assay and best simulated by Monte Carlo with the above Bell parameters and an average of 1.48 bonds [n = 1 bond (67%), n = 2 (22%), n = 3-5 (11%)]. For collision at 100 sec-1, pretreatment of neutrophils with actin depolymerizing agents, latrunculin or cytochalasin D, had no effect on {epsilon}, but increased Lmtether by 1.74- or 2.65-fold and prolonged the average tether lifetime by 1.41- or 1.65-fold, respectively. Jasplakinolide, an actin polymerizing agent known to cause blebbing, yielded results similar to the depolymerizing agents. Conversely, cholesterol-depletion with methyl-{beta}-cyclodextrin or formaldehyde fixation had no effect on {epsilon}, but reduced Lmtether by 66 or 97% and reduced the average tether lifetime by 30 or 42%, respectively. The neutrophil-bead collision assay combines advantages of AFM (small contact zone), aggregometry (discrete interactions), micropipette manipulation (tether visualization), and rolling assays (physiologic flow loading). Membrane tether growth can be enhanced or reduced pharmacologically with consequent effects on PSGL-1/P-selectin lifetimes.

Key Words: cholesterol, hemodynamics, inflammation, neutrophil, selectin, thrombosis




This article has been cited by other articles:


Home page
J. Immunol.Home page
H. Oh and S. L. Diamond
Ethanol Enhances Neutrophil Membrane Tether Growth and Slows Rolling on P-Selectin but Reduces Capture from Flow and Firm Arrest on IL-1-Treated Endothelium
J. Immunol., August 15, 2008; 181(4): 2472 - 2482.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
U. M. Okorie and S. L. Diamond
Matrix Protein Microarrays for Spatially and Compositionally Controlled Microspot Thrombosis under Laminar Flow
Biophys. J., November 1, 2006; 91(9): 3474 - 3481.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2005 by the Biophysical Society.