| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Biophys J, January 2001, p. 169-183, Vol. 80, No. 1


and
*Department of Molecular Biophysics and Physiology, Rush
University, 1750 W. Harrison Street, Suite 1279 JS, Chicago, Illinois
60612 USA;
Departamento de Biofísica, Facultad de
Medicina and Facultad de Ciencias, Montevideo, Uruguay; and
Laboratory of Cardiovascular Science, Gerontology
Research Center, National Institute of Aging, National Institutes of
Health, Baltimore, Maryland 21224 USA
| |
ABSTRACT |
|---|
|
|
|---|
In skeletal and cardiac muscle, calcium release from the sarcoplasmic reticulum, leading to contraction, often results in calcium sparks. Because sparks are recorded by confocal microscopy in line-scanning mode, their measured amplitude depends on their true amplitude and the position of the spark relative to the scanned line. We present a method to derive from measured amplitude histograms the actual distribution of spark amplitudes. The method worked well when tested on simulated distributions of experimental sparks. Applied to massive numbers of sparks imaged in frog skeletal muscle under voltage clamp in reference conditions, the method yielded either a decaying amplitude distribution (6 cells) or one with a central mode (5 cells). Caffeine at 0.5 or 1 mM reversibly enhanced this mode (5 cells) or induced its appearance (4 cells). The occurrence of a mode in the amplitude distribution was highly correlated with the presence of a mode in the distribution of spark rise times or in the joint distribution of rise times and spatial widths. If sparks were produced by individual Markovian release channels evolving reversibly, they should not have a preferred rise time or amplitude. Channel groups, instead, could cooperate allosterically or through their calcium sensitivity, and give rise to a stereotyped amplitude in their collective spark.
| |
INTRODUCTION |
|---|
|
|
|---|
In muscle, action potentials cause intracellular
Ca2+ channels (ryanodine receptors) to open, and
the ensuing Ca2+ release initiates contraction. A
large fraction of this release occurs by superposition of brief
local events, which under fluorescence monitoring appear as
Ca2+ sparks (Cheng et al., 1993
) in cardiac
(López-López et al., 1995
), skeletal (Tsugorka et al.,
1995
; Klein et al., 1996
), and smooth muscle (Nelson et al., 1995
). The
mechanism by which sparks are generated is debatable. They are known to
involve the phenomenon of Ca2+-induced Ca release
(CICR; Endo et al., 1970
; Klein et al., 1996
; Shirokova and
Ríos, 1997
) but in skeletal muscle they should ultimately be
under membrane voltage control. How voltage and Ca2+ interact for the activation of sparks is not
known. Even less is known about the process that terminates sparks,
which was characterized in cardiac muscle as an inactivation (Sham et
al., 1998
), and in skeletal muscle appears to be extraordinarily
effective, as it terminates the sparks abruptly (Lacampagne et al.,
1999
) after a stereotyped time interval of a few milliseconds
(González et al., 2000b
).
To clarify their mechanism, it is important to evaluate the number of
release channels involved in individual sparks (reviewed by Schneider,
1999
; Cannell and Soeller, 1999
; Shirokova et al., 1999
). In this
regard, knowledge of the spark amplitude appears essential, as it
should depend simply on the number of channels involved. Thus, if
sparks were produced by single channels, the distribution of amplitudes
should depend directly on that of open times. This distribution, in
turn, should be monotonically decreasing if the gating of ryanodine
receptors was a homogeneous Markov process, as it is for the vast
majority of channels (Colquhoun and Hawkes, 1995
). Knowledge of spark
amplitudes should additionally help answer other fundamental questions
about mechanism.
There are obstacles to the evaluation of spark amplitude. Because sparks are imaged by line scanning, and those originating farther from the scanned line appear to have less intensity, the reported amplitude depends as much on the true amplitude of the spark (the height of the fluorescent object) as on its placement relative to the scanned line.
Using a discrete model of the array of release channels, Pratusevich
and Balke (1996)
predicted that the histogram of detected amplitudes
would not have a mode even if all spark objects were identical. Cheng
et al. (1999)
generalized a treatment of Shirokova and Ríos
(1997)
to demonstrate theoretically the monotonic character of the
distribution, and confirmed it experimentally for both cardiac and
skeletal muscle. These contributions showed that the experimental
amplitude histogram is far removed from the true distribution of spark
amplitudes. In particular, any mode in the true distribution of
amplitudes is lost due to the limitations of line scanning.
Bridge et al. (1999)
determined the distribution of amplitudes for
sparks originated at repetitive firing units, thus eliminating the
variability introduced by the distance to the scanning light beam, and
found this distribution to have a mode. Although this result weighs in
favor of the involvement of multiple channels, it does not help
interpret the usual amplitude histograms of events originated at
variable, essentially random locations.
Izu et al. (1998)
and Cheng et al. (1999)
demonstrated under different
hypotheses that sets of identical sparks give rise to a distribution of
measured amplitudes of simple mathematical form.
Building on this advance, we present here a method for deriving the
true distribution of spark amplitudes from that of measured amplitudes.
This correction algorithm is then applied to experimental histograms
derived from fluorescence images of frog skeletal muscle fibers under
voltage clamp. The results are of special interest when the events
exhibit a mode in their distribution of rise times, as is the case in
the presence of caffeine (González et al., 2000a
,b
),
corresponding to a stereotyped duration of the underlying release
channel open times.
| |
METHODS |
|---|
|
|
|---|
Experiments were carried out in cut skeletal muscle fibers from
Rana pipiens semitendinosus muscle, voltage clamped in a
two-Vaseline gap chamber on the stage of an inverted microscope. Adult
frogs were anaesthetized in 15% ethanol, then killed by pithing.
Fibers dissected and mounted as described by González et al.
(2000a)
were moderately stretched at sarcomere lengths of 3.2 to 3.6 µm.
The "external" solution contained 10 mM Ca(CH3SO3)2, 110 mM TEA-CH3SO3, 10 mM HEPES, 1 µM tetrodotoxin, and 1 mM 3,4 diaminopyridine. The "internal" solution contained 110 mM cesium glutamate, 1 mM EGTA, 5 mM glucose, 5 mM magnesium ATP, 5 mM phosphocreatine, 10 mM HEPES, 0.2 mM fluo-3 (Molecular Probes, Eugene, OR), and had calcium added for a nominal [Ca2+] of 100 nM and magnesium chloride added for a nominal [Mg2+] of 0.61 mM. Solutions were titrated to pH 7 and adjusted to 270 mOsmol/kg. Experiments were at 17°C.
Details of chamber design and voltage clamp were given by Shirokova and
Ríos (1997)
and Ríos et al. (1999)
. The scanning microscope (MRC 1000, Bio-Rad, Hercules, CA) was in standard fluo-3 configuration (Ríos et al., 1999
) and used a 40×, 1.2 numerical aperture water immersion objective (Zeiss, Oberköchen,
Germany). Images shown are of fluorescence of fluo-3, determined at
2-ms intervals at 768 points of abscissa
xj along a line parallel to the fiber
axis. Fluorescence intensity, F(x,t),
was always normalized to the baseline intensity
F0(x), derived as an
average of F(x,t) before the
depolarization pulse was applied.
Sparks were located automatically (Cheng et al., 1999
) by a relative
amplitude criterion, separation from the local fluorescence level by
more than 2.5
n (standard deviations of the
normalized light intensity in the image; González et al., 2000a
).
We reduced the frequency of false detections by a number of safeguards
described by González et al. (2000a)
. Because the frequency of
spontaneous events was extremely low, the frequency of false detections
could be estimated (at ~10%) by applying the method to resting images.
Morphological parameters were determined on the detected events as
described by González et al. (2000a)
. In particular, amplitude a was determined as difference between the peak value of the
normalized fluorescence and its baseline value at the same spatial
position immediately before the event (the average of 10 values between 40 and 20 ms before the peak); full width at half magnitude (FWHM) was
determined on the spatial distribution of fluorescence at the time of
maximum change, and rise time was determined on a spline interpolate of
the time dependent fluorescence, averaged over three spatial pixels at
the center of the spark, as the interval between time to 10% increase
from pre-event baseline and time to peak.
Single variable histograms are represented by bars or curves (chosen
for best visibility) normalized as probability densities. Joint
histograms are represented after interpolation by the method of
parametric cubic convolution (Park and Schowengerdt, 1983
).
| |
THEORY |
|---|
|
|
|---|
The relationship between detected and full amplitudes
The goal of this section is to derive the distribution of full
spark amplitudes of probability density (pdf)
g(a) from the distribution of spark amplitudes
(of pdf f(a)) in a line scan image. To simplify
notation, f(a) represents interchangeably the distribution and its sampling approximation, (normalized) frequency in
amplitude histograms. To derive g from f, an
expression is first developed for the inverse transformation, which
produces f starting from g. To this end we expand
work of Shirokova and Ríos (1997)
, Cheng et al. (1999)
, and Izu
et al. (1998)
. (Izu et al. (1998)
considered the transition from
spark strength (intensity or open time of the underlying channels), to
observed amplitude. In the present work the spark is taken as a
fluorescent object of a given magnitude and time course, and the
process of release and diffusion leading to spark formation is not considered).
The theory is valid for analysis of images obtained by line scanning in a direction parallel to the fiber axis. The spread in measured spark amplitudes may result from variation in actual spark size or from variable separation of the spark source relative to the scanned line. In frog muscle sparks originate at triad junctions in the Z disks, of which there is one per sarcomere. A Cartesian coordinate system is defined in which the x axis is the scanned line (x,0,0), x and y are in the focal plane and z is the vertical. In this frame of reference, the Z disk corresponds to the plane (0,y,z). Even though sparks occur there only at triads, one has no information about location of triads relative to the scanning line, which effectively results in homogeneous probability of spatial spark location within y,z space. This property was used, together with the experimentally recorded spark waveform, to generate the amplitude histogram f(a).
Fig. 1 shows in conventional spatio-temporal representation an experimental spark, acquired by line scanning of a voltage-clamped cell, as a fluorescence intensity F(x,t), normalized to the baseline fluorescence F0(x) and smoothed. (Line scan images from this cell are illustrated in Fig. 4). Because this was one of the largest sparks recorded in the image (and in the experiment) it is reasonable to assume that it originated close to the scanned line (x,0,0), an assumption validated in Appendix B. The spark's amplitude, that is, the peak value of the increase in fluorescence, will be termed henceforth full amplitude, to emphasize that the spark would have been detected with a lower amplitude, had it originated farther from the scanning line. The descriptive term "full" is preferred to "true" amplitude, because even when a spark is ideally centered on the scanning line, its image, F(x,t), is blurred (scaled down and widened).
|
On the same graph in Fig. 1 the maxima of the functions of time F(x,t) at constant x are joined with a white trace. The black trace, obtained by projection of the curve in white, defines Fmax(x), which decreases monotonously with x .
Under the assumption that sparks, considered as fluorescent objects,
are spherically symmetrical (an assumption valid for most sparks, as
shown by video-rate scanning in two dimensions, Brum et al.,
2000
), Fmax(x) can
be given a different interpretation: it is the amplitude a
with which a spark similar to the one shown would be reported, if it
originated on the y axis, at distance x away from
the scanned line. In other words,
Fmax(y) is the amplitude at
which the spark shown would be detected if it originated at (x,y,0) instead of (x,0,0). We
therefore use the measured intensity maxima at the x axis
(Fmax(x), detected
amplitude function) as a predictor of the downsizing effect of
separating scan from spark.
To generalize this approach to three spatial dimensions, a similar use
could be made of Fmax(x) to
scale the amplitude when the separation is in the z axis
direction. However, the spread of confocal imaging is greater in the
axial direction than in the focal plane. This difference was taken into
account using the measured point spread function (PSF) of our
confocal system (Ríos et al., 1999
) as follows:
F(x,t) was first corrected for the
blurring produced by the microscope by deconvolving it, at every
t value, with the system's x axis PSF (a
Gaussian function of x, of FWHM = 0.4 µm). Provided that sparks, as objects, are symmetric, the function thus obtained, F*(x,t), also describes the dependence of the
spark on y and z, as
F*(
,t), where
=
.
F(y,z,t), the blurred image of the
spark, was then constructed by convolving
F*(
(y,z),t) with the
system's two-dimensional PSF (a Gaussian of
FWHMy = 0.4 µm and FWHMz = 1 µm). The detected amplitude function
a(y,z) (represented in Fig.
2 A), was obtained as
Fmax(y,z), the maximum of
F(y,z,t) over t at fixed positions y, z. Unlike F*,
a(y,z) is not spherically symmetric.
a(y,z) can be imagined as the result
of making a radially symmetrical volume from the curve
Fmax(x) and broadening it
in the z direction.
|
a(y,z) is all that is needed to generate the amplitude histogram that would apply if all sparks were equal in morphology to the one shown. Indeed, the function a(y,z) represents recorded amplitude as a function of location, and the probability of occurrence of such locations is simply proportional to the area occupied by such locations in the Z disk (the y,z plane).
Let n be the average number of sparks (all assumed to be
equal) produced per unit area of one Z disk. The frequency of measured sparks of amplitude greater than a will be n
multiplied by the area of a (roughly elliptical) region, or resel,
where the intensity is greater than a (see Fig. 2
A). The frequency in an interval da (approximated
by the bin value in the amplitude histogram of detected events) is
proportional to the area in the ring bounded by two resels, where the
amplitude increases by da. Symbolically,
|
(1) |
Eq. 1 can be used as a numerical recipe to calculate the amplitude
histogram whenever a(y,z) is known.
Using it with the function a represented in Fig. 2 (and
n = 25, 600) the histogram in Fig. 2 was obtained. As
described before (Izu et al., 1998
; Cheng et al., 1999
), the histogram
is monotonously decreasing, even though the full amplitude of the
sparks is always the same.
The continuous line in Fig. 2 B is the best fit by
the function k/a. This one-parameter fit is
extremely good over the entire range of amplitudes. A similarly good
fit was found for the amplitude histograms generated with all other
sparks tested, large or small. The conclusion that the amplitude
histogram of a stereotypical spark should follow the reciprocal
function was derived analytically by Cheng et al. (1999)
and reached
through a very different set of considerations by Izu et al. (1998)
. In
Appendix A, we demonstrate that when the detected amplitude function
a is a Gaussian function of y and z,
with standard deviation
, the resulting amplitude histogram is
exactly
|
(2) |
It is a simple task to generalize this result and determine the
amplitude histogram when the object sparks have multiple amplitudes. Assume, first, that there are a few discrete components in the distribution. Specifically, if the frequency of sparks of full amplitude
, g(
), is nonzero only for a finite set of
discrete
j, then the histogram of
amplitudes in the line-scan, f(a) can be written
as a sum of discrete contributions of form (2) for each of the
subgroups of amplitude
j
|
(3) |
When the distribution of full amplitudes is continuous, Eq. 3
becomes:
|
(4) |
(
)2/a), with coefficients
g(
). In this sense, the goal of this section is to invert
such transform. This is accomplished solving Eq. 4 for
g(
) by differentiating the integral with respect to the first limit of integration:
|
(5) |
|
(6) |
. The
disappearance of the argument
in the final expression of Eq. 6
reflects the fact that the full amplitude is not known for individual
sparks, and the algorithm yields only its distribution, g.
A test of the algorithm with simulated distributions
Eq. 6 is the relationship sought between g, the
distribution of full amplitudes, and the amplitude histogram
f of events in a line scan. It is strictly valid only when
the detected amplitude function
(a(y,z)) is Gaussian. This is not true
in general, but appears to be a good approximation in most cases.
Moreover, the half-width of sparks is poorly correlated with amplitude,
both for experimental sparks (as shown by González et al., 2000a
; see also Discussion) and in simulations (Ríos et al., 1999
), suggesting that the Gaussian
in Eq. 6 may be regarded as constant in a first approximation. The algorithm in Eq. 6 should therefore work
as an approximate way of deriving g in real situations. In the remainder of this paper, the right-hand side of Eq. 6 is presented normalized as a probability density, and referred to as g or
corrected amplitude distribution. (Normalization is done dividing the
right-hand side of Eq. 6 by the integral of its non-negative
portion over the whole amplitude range and by the binning interval.
Negative values of g arise wherever a
f(a) increases with a, presumably due to
noise or imperfect detection.)
The procedure was tested by applying it to amplitude histograms derived from known (simulated) distributions of sizes, using actual, experimentally recorded sparks.
Fig. 3 illustrates the test. At the top
in Fig. 3 A is a histogram of detected amplitudes (thick
trace), calculated numerically assuming that there are only three
subpopulations of sparks: one of them is composed of clones of that in
Fig. 1, of full amplitude 3.25. The other two sets are clones of two
other sparks from the same experiment, with full amplitude 2.2 in one
case and 4.7 in the other. Curves f1
to f3 in Fig. 3 A represent
the individual contributions of each set to the amplitude histogram,
calculated assuming equal n for each set. The contributions
are similar up to a limiting detected amplitude, which in each case is
equal to the full amplitude of each spark (the
j values of Eq. 3, namely 2.2, 3.25, and 4.7). If the detected amplitude functions of these sparks
were Gaussians of equal
, these contributions would be functions
k/a, exactly overlapping up to the corresponding
j. They do not exactly overlap
because they were derived from real sparks.
|
The curve in thick trace was obtained according to Eq. 3, by linear
combination of the fj values with
coefficients g(
1) = 2, g(
2) = 4, and
g(
3) = 1, chosen arbitrarily
to have a mode in the discrete distribution g(
), at the
intermediate amplitude 3.25. This is, therefore, an amplitude histogram
derived from actual experimental sparks and a simulated distribution.
To this histogram we applied Eq. 6. If the detected amplitude functions
were Gaussian, the result would be exactly
2g(a). The result is
plotted in Fig. 3 B. The procedure recovered three peaks, at
the correct amplitudes, with ordinates of relative values 1.74, 3.29, and 1 (close to the starting g values of 2, 4, and 1). An
even better agreement is found by integration of the areas under the
three peaks, which yields relative values of 1.95, 3.50, and 1. Discrepancies are expected, because the individual histograms are not
exact reciprocal functions (k/a), and because the
algorithm recovers the distribution function g(a) multiplied by the width parameter
2, which is
not strictly a constant. A test with a smaller number of sparks
(n = 1024) gave three peaks of similar relative values, on a noisier baseline, especially at low values of a.
| |
RESULTS |
|---|
|
|
|---|
In the previous section a method was developed to derive the true distribution of amplitudes, starting from their distribution in confocal line scans. The method was then tested, with good results, on histograms derived from experimental sparks, but with an assumed (arbitrary) distribution.
In this section we use the algorithm on actual histograms of
experimental sparks. The true distribution in these cases is unknown,
and therefore the adequacy of the algorithm cannot be assessed with
certainty. To test the algorithm we took advantage of the fact that two
other morphometric parameters of the spark, rise time and width, can be
determined with more certainty than the amplitude. Modeling by several
laboratories has shown these two parameters, especially rise time, to
be less affected by off-focus errors (Pratusevich and Balke, 1996
;
Smith et al., 1998
; Jiang et al., 1999
).
For many sets of sparks, especially but not necessarily in the presence
of caffeine, the distribution of rise times exhibited a clear mode
(González et al., 2000
). In these cases the true distribution of
amplitudes should also have a mode. Indeed, rise times of sparks are
essentially the times when the underlying release process is active.
Hence, if release times (open times of the release channels) are
stereotyped or modal, true amplitudes are expected to have a preferred
value as well (or a dearth of the very small events resulting from very
short open times, which effectively results in at least one mode in the
amplitude distribution). This expectation does not rely on any
assumption about the number of channels involved in one spark.
This section compares first the presence of modes in the corrected amplitude distributions and in the distribution of rise times. Later, comparisons are extended to joint distributions of rise time and width.
Amplitude distributions in the presence of caffeine
Two studies (González et al., 2000a
,b
) demonstrated that
fibers in caffeine often exhibit a mode in the distribution of rise times. The same experimental database is analyzed here for
distributions of amplitudes and widths. As described in detail by
González et al. (2000a)
, spark properties were studied in
multiple line scan images, obtained at different locations in a
voltage-clamped fiber. Fig. 4
A illustrates images obtained from the same cell, in
reference solution, and after addition of 1 mM
caffeine. The fibers, prepared as described in
Methods, had no or few spontaneous sparks. Depolarizing pulses of long
durations were applied at 1-min intervals, to voltages near
60 mV in
reference, sufficiently high to maximize the numbers of events while
keeping them sufficiently separate to avoid overlap and increase in
global fluorescence. The pulses applied in the presence of caffeine
were typically of 5 or 10 mV lower amplitude to avoid increasing event
frequency. Sparks were located automatically, using a relative
amplitude criterion (see Methods).
|
In the experiment illustrated, 548 events were detected in 7 images in
reference, and 883 events in 10 images obtained subsequently, in the
presence of 1 mM caffeine. (Large numbers of events, detailed in the
table, are the rule for all distributions shown.) Fig. 4 B
shows a broad mode in the histogram of rise times in the presence of
caffeine. Evidence that this mode is real, rather than an artifact of
limited detection of smaller events, was given by González et al.
(2000b)
. In Fig. 4 C are the corresponding histograms of amplitudes. As predicted by the theory, the distribution of amplitudes is decreasing. The mode in the third bin is a trivial artifact of
failed detection of the smallest events, as it moves to the left when
the detection criterion is lowered (González et al., 2000b
; Cheng et al., 1999
). The measurable frequency of events of amplitude >5 in reference, but not in caffeine, was an unusual observation.
Fig. 4 D represents the functions
2
g(
), obtained from the amplitude histograms by the
correction algorithm, Eq. 6, and normalized as a probability density;
we refer to these functions simply as "corrected distributions" or
g(a). A clear mode, at an amplitude ~4, was
present in caffeine but not in reference; the small peak at low
amplitudes should be disregarded, as it reflects detection limits. The
mode was robust upon several procedural changes, including changes in
binning interval or starting value, and in the amplitude threshold for
detection (illustrated later). The mode was also present when an
absolute amplitude criterion, rather than one relative to noise, was
used for detection (Cheng et al., 1999
). As documented in Table
1, the appearance of a mode in caffeine was quite reproducible, and the mode location is representative of that
found in several experiments.
|
The presence of a mode in the corrected distribution of amplitudes did not require caffeine. However, it did correlate very strictly with the presence of a mode in the distribution of spark rise times. Figs. 5 and 6 illustrate two examples. At top in Fig. 5 is the histogram of rise times for 923 events in 12 images in reference (no caffeine was applied in this experiment), featuring a mode at 6 ms. The histogram of amplitudes, Fig. 5 B, is monotonically decaying, whereas the corrected distribution, Fig. 5 C, features a clear mode at amplitude 6.
|
|
Modes in the distribution of amplitudes are statistically significant
The example in Fig. 5 illustrates two tests of the
significance of the mode in the corrected distribution.
g(
) results from the differentiation of a
f(a) (Eq. 6), so that a mode in g
corresponds to a large jump in a f(a). To test
the statistical significance of the change in a
f(a) we compared the running difference
af
(ai
f(ai)
ai
1f(ai
1))
with
SD, an estimator of its standard error, calculated assuming
that the bin frequencies in f(a) have a Poisson
distribution (e.g., Reif, 1962
), as
SD =
.
In the null hypothesis that
af is zero (implying that all
sparks have one and the same amplitude), the ratio
af/
SD should have approximately a t
distribution. Its number of degrees of freedom,
n(f(a)I + f(a)I
1), is >20 at the
amplitudes of interest, so that the t distribution is
indistinguishable from a Gaussian.
af/
SD is plotted versus amplitude in Fig. 5
D. It appears not to have a t distribution, as it
is positive at all but one value of a. This suggests that
the null hypothesis may be wrong at all amplitudes; in other words,
g is probably different from zero in the range of amplitudes
represented
there are sparks of many different amplitudes. It is only
at a = 6, however, that
af/
SD is
different from 0 at a P < 0.05 (in fact,
P < 0.0005), indicating that the mode in g
is probably real, not due to the limited size of the sample.
An additional test relied on the fact that a mode not determined by
noise should remain upon increasing noise. The set of events was
divided randomly into two sets of half the size, and the correction
algorithm was applied to the amplitude histograms of the half-sets,
yielding the two dashed plots in Fig. 5 C. Other divisions
in two of the original set gave similar results. This procedure is
roughly equivalent to increasing noise in the histograms by a factor of
. Whenever
af was greater than 3
SD, the
mode was robust upon halving the sample size. Both tests are,
therefore, approximately equivalent indications that the modes
correspond to actual features in the distribution of amplitudes.
Correlation between modes in amplitude and rise time
Although g(a) was usually modal in the presence of caffeine, the situation in reference conditions was quite variable. A monotonic distribution was illustrated in Fig. 4 and a modal one in Fig. 5. Fig. 6 illustrates an experiment in which the events recorded before caffeine had a modal distribution g; the mode became more marked in the presence of caffeine, and disappeared upon washout. In remarkable agreement, the distribution of rise times (Fig. 6, A-C) had a well defined mode in the presence of caffeine, one less marked in the reference situation before caffeine, and appeared to be monotonic upon washout.
Results in multiple cells are listed in Table 1, where the headings "ref" and "caff" identify the condition. Columns 2 and 3 list the numbers of events detected in each case. Columns 4 and 5 list the location of the mode, if present, in the corrected distribution of amplitudes. Columns 6 and 7 note the significance of these modes, determined by the two tests described above. Columns 8 and 9 give the locations of the modes in the distributions of rise times for the same sets of events.
The table indicates that 5 of 11 cells in reference had a mode in g(a). Nine of these cells were exposed to caffeine. In four of those the mode was not present in reference but all but one developed a mode in caffeine. In two of the others the mode, which was present but not significant in reference, became significant in caffeine. Even when the mode was significant in reference, it increased in density and definition in caffeine. The abscissa of the mode decreased slightly in caffeine.
The table also lists the location of the modes in rise time
distributions. As shown in Figs. 4-6, a mode is always present in those distributions. However, it is usually at one of the first few
bins in the histograms, where it may be due to failure of detection of
very brief events. González et al. (2000b)
concluded that modes
located at times greater than 4 ms are probably real, and the present
comparison indirectly agrees with that conclusion. When the modes of
rise times were at less than 3 ms, there was either no mode in
g or the mode was not significant. When the mode was at
greater than 4 ms, the mode in g existed and was
significant. The simplest interpretation is that the presence of modes
in the distribution of rise times results in modal distributions of
amplitude, and that the modes at rise times greater than 4 ms and those
present in the g(a) graphs correspond to real
features (preferred open times and amplitudes) of the sets of events.
Borderline cases, when rise times were grouped around 3 or 4 ms, are
clarified by the analysis of joint distributions.
The joint distribution of rise time and width
As stated, the measured amplitude of sparks depends strongly on the position of the source relative to the scanning line. Therefore the strategy of the previous sections was to compare the corrected amplitude distribution with the much more robust distribution of rise times. Because spark spatial width increases with source intensity and open time (as does spark amplitude), the measurement of width (FWHM) provides an independent test of the adequacy of the amplitude correction algorithm.
Joint histograms of rise time and width, especially after interpolation
by the cubic convolution procedure of Park and Schowengerdt (1983)
,
reveal more clearly the presence of modes than the single variable
histograms (González et al., 2000a
). For this reason, the
features of the joint distribution exhibit a much more detailed correspondence with modes in g(a) and help
clarify cases when the modes in rise times are dubious.
A first example is illustrated in Fig. 7, an experiment in which both the distribution of rise times and the g(a) had a mode in reference. However, the mode of rise times at the second bin of the histogram (2-4 ms) was suspect. The joint histogram in reference, Fig. 7 A, shows two modes, termed "large" and "small" for brevity: "small" at a rise time of 2.5 ms and a width of ~0.9 µm, and "large" at ~4.5 ms and 1.8 µm. In good correspondence, the amplitude distributions g(a), plotted in Fig. 7 D, feature two modes in reference. In 0.5 mM caffeine, Fig. 7 B, the joint histogram features only the large mode, as if most events in the small mode had become large. This corresponds well with the change in g(a) (Fig. 7 D), which in caffeine exhibits essentially a single mode, with the same abscissa as the one at greatest a in reference. Hence, the joint histograms exhibit a detailed correspondence with the corrected amplitude distributions and clarify that the single mode in the rise time histogram in reference really includes two modes or types of events, the nature of which is explored later.
|
The correspondence between the number of modes in the joint histograms and that in g(a) would be meaningless if modes in amplitude did not map onto the modes in the joint histogram. Fig. 7, E and F, illustrates such mapping. Events in reference were separated in two groups, of measured amplitude greater or less than 3 (the value that separates the peaks in g(a), Fig. 7 D). In Fig. 7 E is the joint histogram of events with amplitude greater than 3. As expected, most of them map to the large mode in the joint histogram.
Due to the nature of the correction, the mapping is not bijective (or one-to-one). In Fig. 7 F is the joint histogram of the events of amplitude less than 3. This group does not and should not map specifically to the small mode. Indeed, events can have low measured amplitudes because they are truly small (mapping to the mode of lower rise time and width), or because they are large but off-focus (belonging to the large mode of the joint distribution). The mapping between modes in g and modes in the joint histogram, therefore, indicates that the algorithm works correctly.
Of the two modes in the joint distribution, the small one probably
reflects a group of smaller events whose distribution is curtailed by
limited detection. When the threshold for detection was lowered to
2
n (cf. Methods), a small mode appeared in
caffeine (Fig. 7 G). Moreover, when the detector was applied
with lowered threshold to images obtained at the holding potential,
only the small mode was left (Fig. 7 H) indicating the
presence of false events in this mode. The large mode, instead, was
robust upon change in detection threshold (Fig. 7 G), and
essentially devoid of false events (Fig. 7 H), both
indications that it is not artifactual (González et al., 2000b
).
When the joint distribution failed to show modes, so did the corrected distribution of amplitudes. Fig. 8 illustrates two examples. In Fig. 8 A is the joint histogram of a cell that was studied in reference only, exhibiting a widely spread distribution, with many events of long rise times but only the trivial small mode. The density g(a), in Fig. 8 B, is monotonically decreasing from a peak at low amplitude. This agreement was the rule. The other panels in the figure contain the joint histograms for the experiment in Fig. 4, in which the corrected density g(a) was monotonous in reference, but had a mode in 1 mM caffeine (Fig. 4 C). Accordingly, the joint distribution went from having just the small mode in reference, at rise time between 2 and 3 (Fig. 8 C), to having an additional broad mode in caffeine (Fig. 8 D). In this situation, all events of amplitude >2 (belonging to the caffeine-induced mode in g(a)) mapped onto the new mode in the joint histogram (image not shown). As was the case for the experiment in Fig. 7, the events of amplitude <2 did not map to either mode in the joint histogram.
|
| |
DISCUSSION |
|---|
|
|
|---|
This paper communicates an advance in the theory of line scanning
of Ca2+ sparks, which made possible a new method
of analysis and led to a new experimental observation. We extended the
theory of imaging by confocal scanners (Pratusevich and Balke, 1996
;
Shirokova and Ríos, 1997
; Izu et al., 1998
; Cheng et al., 1999
)
to derive the mathematical form of the histogram of spark amplitudes.
Using a numerical computation (Eq. 1) based on the detected amplitude function (Fig. 2), we showed that the amplitude histogram
f(a) is well approximated by an inverse
proportionality, k/a, when all sparks are
identical. Using this approximation we could then define an algorithm
(Eq. 6) to recover the true distribution of spark amplitudes from the
amplitude histogram experimentally determined in line scans. When
applied to amplitude histograms from sparks with a modal distribution
of rise times (which was generally the case in cells exposed to
caffeine), the algorithm produced amplitude distributions with a mode.
The algorithm yields the function
2g(a), where
is the
standard deviation of the approximating Gaussian. Therefore, the result is not strictly an amplitude distribution. For example, if the true
distribution consisted of some small and narrow sparks, and others that
were large and wide, then the algorithm would overestimate the
frequency of large sparks. The parameter
that appears in Eq. 6 is
the true width, the one reported when sparks are centered on the
scanned line. The width of the largest sparks in any given image varies
within a narrow range. Consequently, the result of the algorithm is
approximately proportional to g(a).
Tests of the correction algorithm
The algorithm was tested successfully (Fig. 3) on histograms constructed using experimental sparks, rather than the Gaussian idealization that makes the algorithm exact. The test proved the mathematical consistency of the algorithm, and was an independent verification of goodness of the assumptions (including Gaussian profile of sparks, their approximately constant spatial width, and the random location of their sources within the plane of the Z disks).
When the algorithm was applied to experimental amplitude histograms, the resulting density g(a) was positive at almost every measured value of a (consistent with the presence of events of every amplitude, that is, a continuous distribution of true event amplitude within the measured range) and had a mode in many cases. The mode could be a simple artifact of noise in the histograms. To test this hypothesis the value of g(a) (strictly, of the change in a f(a), proportional to g(a)) was compared with its probable error. The g(a) value was significantly different from zero only at or near the modal amplitude, which suggests that the mode is not fortuitous. In a related test, the modes were found to be still present when noise in the histogram was increased by halving sample size. These tests effectively ruled out noise as a determinant of the mode.
The algorithm cannot undergo a rigorous test on experimental data
because the true amplitude distribution of experimental sparks is
unknown. To circumvent this problem, we relied on a fact first
indicated by Pratusevich and Balke (1996)
and confirmed under different
assumptions by others (Smith et al., 1998
; Jiang et al., 1999
), namely,
that rise times and, to a lesser extent, spatial widths are robust
under line scanning, varying little with the distance between scanning
line and spark origin.
In other words, one may know rise times and widths with reasonable certainty, even for out-of-focus sparks. Hence, if a mode is present in the distribution of rise times, then events of very low amplitude, corresponding to very short rise times, should be comparatively less frequent. This should result in a distribution whose pdf increases with amplitude at low values of the amplitude. Hence, if the correction algorithm was adequate, it should produce a g(a) with a mode. Indeed, there was an excellent correlation between the presence of a mode in the distribution of amplitudes and in that of rise times.
In some cases the result of the comparison was inconclusive, usually because a mode at low values of rise time could be artifactual. In these cases the joint distribution of rise time and spatial width often exhibited two modes, of which one (small) was artifactual and the other was robust upon changes in detection sensitivity and/or binning. Whenever a significant mode was present in the joint distribution, the density g(a) exhibited a clear mode at large a. Moreover, there was the expected mapping: the events that were large and closer to focus, i.e., those with an amplitude near the large mode in g(a), mapped exclusively to the large mode in the joint histogram.
The success of the test with simulated distributions, together with the
observed correlation between the presence of modes in rise times,
widths and amplitudes, indicate that the algorithm is qualitatively
correct. At the same time, the result reinforces the conclusion
(González et al., 2000b
) that the modes in rise time, observed
not only in the presence of caffeine, but also in some experiments in
reference, are real, rather than artifacts of the detection procedure.
(The correspondence between amplitude and rise time distributions may
be used conversely, to argue that events of greater rise time tend to
have greater amplitude. This statement, however, would only apply to
full amplitude, which is unknowable for an individual event. For
measured amplitudes, the off-focus error may be so large that the
correlation is lost, as suggested by observations of González et
al. (2000b)
and Lacampagne et al. (1999)
.)
Modal rise times require irreversible gating
The significance of a mode in the distribution of rise times has
been discussed previously (Cannell and Soeller, 1999
; Bridge et al.,
1999
; González et al., 2000a
). Its presence is not
explicable if sparks are due to the opening of one Markovian channel
evolving reversibly (a channel whose transition rate constants depend
on the present state only, and in addition satisfies microscopic reversibility, e.g., Colquhoun and Hawkes, 1995
), because the open time
distributions of such channels are sums of decaying exponentials. By
contrast, a channel that evolves irreversibly can have modal open time
distributions (Colquhoun and Hawkes, 1995
). Channels that gate
irreversibly have been identified (Schneggenburger and Ascher, 1997
;
Chen and Miller, 1996
), but we know of only one example in the
literature of a channel with nonmonotonic open time distribution
(Gration et al., 1982
). In support of the possibility of irreversible
gating, the Ca release channel is known to be regulated by the
permeating ion (Tripathy and Meissner, 1996
; Xu and Meissner,
1998
), and therefore has the capability to derive energy from
the [Ca2+] gradient and evolve irreversibly. A
model that features interaction with the permeating ion has been
developed by Wang et al. (2000)
and shown to have stereotyped rise
times. These simulations, however, must be considered only a
theoretical demonstration of possibilities, because the actual
distributions of open times in bilayers, for channels conducting
Ca2+, do not have clear modes (Wang et al.,
2000
).
The couplon model produces modal amplitudes
A mode in the amplitude distribution comes naturally instead,
assuming that groups of channels underlie sparks, as argued by
Shirokova et al. (1999)
. For example, in the couplon model (Stern et
al., 1997
) sparks are produced by arrays of sarcoplasmic reticulum channels (couplons) along one side of a junctional
segment (Franzini-Armstrong and Jorgensen, 1994
) of transverse tubule. In simulations the sparks from a couplon of 28 channels and 0.3 pA
unitary current had multiple amplitudes (due to the stochastic variation in the number of channels involved in individual sparks, as
well as the variable open times), but with a clear mode in their
distribution, at amplitude 1.3 (Fig. 18 of Stern et al., 1997
). When we
repeated the simulation with unitary current of 1 pA (which could be
closer to the value in frog muscle; Kettlun et al., 2000
) the mode
moved to an amplitude ~4.0. An additional source of variation in
amplitude would be the spread in couplon size, resulting in an overall
distribution that, in reference, might not have a mode. Therefore, the
couplon model explains qualitatively the presence of a mode in the
distribution of amplitudes, and generates sparks of reasonable size.
Simulations with couplons of increasing length led to better-defined
modes, of course at greater amplitudes (Stern et al., 1997
). Under
caffeine, the effects of which include increased CICR sensitivity
(Herrmann-Frank et al., 1999
), the number of channels activating in a
spark would increase, leading to the better definition of modes.
A couplon simulation of the effects of increased CICR sensitivity is
presented in Fig. 9. The calculations are
carried out using the definitions of Stern et al. (1997)
and the set of
parameters listed in their Table 1. Half of the channels in the couplon
are supposed to be Ca2+-sensitive, gating among
four states according to the diagram in A, where activation (C
O) and
inactivation (O
I) are driven by Ca2+ binding
to specific sites. The graphs illustrate the effect of increasing the
sensitivity to activation by Ca2+, represented in
the model as an increase in ko, the
forward constant of the C
O transition. Shown is the distribution of
maximum number of channels open simultaneously, in 10,000 discrete
events occurring in multiple Monte Carlo realizations of the model. The
distribution exhibits an ill-defined mode in the "reference"
condition of lowest ko (A). The mode
shifts to higher numbers and increases its definition when
ko is doubled (B) or quadrupled (C).
Additional effects, not illustrated, are an increase in the mean and
mode of the distribution of event durations, and a shift and increase
in definition of the mode in the amplitude distribution, similar to
that in the number of open channels.
|
Through changes in a single parameter, the simulation therefore
reproduces the observed effects of caffeine, with an important exception: it predicts an increase in amplitude, while no increase in
average amplitude was observed in the present experiments (even for the
corrected g distribution), and only a minor one was found in
the study of González et al. (2000a)
. Reasons for the discrepancy include an increase in resting fluorescence (which directly reduces the
normalized amplitude of the events) and partial depletion of
Ca2+ (because a measurable increase in resting
fluorescence probably reflects an increase in resting
[Ca2+], hence a displacement of
Ca2+ away from the sarcoplasmic reticulum).
In spite of these reasonably successful simulations, the couplon model
should not be regarded as a definitive resolution of spark mechanisms.
It implements ad hoc a Ca2+-dependent
inactivation process that is inconsistent with the inactivation
properties of release channels in bilayers (for assuming a dissociation
constant of 10 µM for the inactivation site). Additionally, it fails
to produce the almost synchronous closure of channels demanded by the
rapid termination of release in sparks (Lacampagne et al., 1999
).
Average amplitude of Ca2+ sparks
As stated, the true amplitude of an individual spark is
unknowable, because the location of the source is never determined. The
present algorithm, however, provides statistical knowledge (the
distribution g of amplitudes) and affords central measures: mode, median, or mean. It is interesting to compare such measures of
the corrected distribution with those of the distribution of measured
amplitudes (the amplitude histogram). The table shows that the mode of
the distribution g is approximately 2.5 times greater than
the average of the measured amplitudes (the other central measures of
g, not listed, are close to the mode). Obviously, this ratio
is somewhat variable, as it depends on the sensitivity of the detector
and the threshold at which it is set, but is sufficiently well defined
to provide a useful rule of thumb: when nothing is known regarding the
position of a spark, its amplitude is likely to be underestimated two-
to threefold, due to the uncertainty in location of the source relative
to the scanning line. This is an important consideration, for instance,
when using the amplitude of sparks as indication of the underlying
currents and numbers of channels. Rather than the average amplitude
(used, for instance, by Ríos et al., 1999
), an adequate model
should account for an amplitude 2 to 3 times greater.
| |
APPENDIX A: AMPLITUDE HISTOGRAM OF A GAUSSIAN SPARK |
|---|
|
|
|---|
The goal is to prove that the amplitude histogram of sparks in a
confocal line scan image has the analytical form given by text Eq. 2 in
a special case. The detected amplitude function a(y,z), illustrated in Fig. 2
A, is defined as the amplitude with which a spark of full
image amplitude amax would be detected
in a line scan if it originated at a position
x,y,z and the scanned line was at
(x,0,0). The detected amplitude function is derived from an
experimental spark F(x, t) using the assumption
that the spark is spherically symmetric. We will assume for simplicity that the imaging properties of the microscope (determining its PSF) are
also symmetric. Under these hypotheses
a(y,z) is also symmetric.
Specifically, it is a function a(
) of the distance
=
from the spark center to the scanned line, and the functional
dependence, a, is the same as that of
Fmax(x), derived from the
spark F(x, t) as described in the text.
Then, according to Eq. 1, when sparks of the same form are generated at
random positions in the Z disks, at a rate of n per unit
area of Z disk (during the time when the image is collected), the
frequency of sparks in the image with detected amplitudes within an
interval (a, a + da) will be
|
(A1) |
(a) is the inverse of a(
),
existent because a(
) is strictly monotonic.
The differential equation A1 can be integrated when a(
)
is Gaussian, that is:
![]() |