| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Biophys J, May 2002, p. 2396-2414, Vol. 82, No. 5
Department of Physiology, University of Auckland School of Medicine, Grafton, Auckland 1, New Zealand
| |
ABSTRACT |
|---|
|
|
|---|
Using a combination of experimental and numerical approaches, we have tested two different approaches to calculating the sarcoplasmic reticulum (SR) Ca2+ release flux, which gives rise to cardiac muscle Ca2+ sparks. By using two-photon excited spot photolysis of DM-Nitrophen, known Ca2+ release flux time courses were generated to provide the first experimental validation of spark flux reconstruction algorithms. These artificial Ca2+ sparks show that it is possible to calculate the SR Ca2+ release waveform with reasonable accuracy, provided the flux equations reasonably reflect the properties of the experimental system. Within cardiac muscle cells, we show that Ca2+ flux reconstruction is complicated by the substantial dye binding to proteins, a factor that has not been adequately addressed in previous flux reconstruction algorithms. Furthermore, our numerical experiments suggest that the calculated time course of release flux inactivation based on conventional flux reconstruction algorithms is likely to be in error. We therefore developed novel algorithms based on an explicit dye binding scheme. When these algorithm were applied to evoked Ca2+ sparks in rat cardiac ventricular myocytes, the reconstructed Ca2+ release waveform peaked in ~5 ms and decayed with a halftime of ~5 ms. The peak flux magnitude was 7-12 pA, suggesting that sparks must arise from clusters of >15 ryanodine receptors.
| |
INTRODUCTION |
|---|
|
|
|---|
Transient microscopic elevations in cytosolic
Ca2+ concentration, termed "Ca2+ sparks,"
were first discovered in ventricular cardiac muscle cells labeled with
the Ca2+-sensitive indicator dye fluo-3 (Cheng et al.,
1993
). Subsequently, Ca2+ sparks were also observed in
other striated and smooth muscle cells (Tsugorka et al., 1995
; Klein et
al., 1996
). The spatio-temporal summation of individual
Ca2+ sparks can explain the cell-wide Ca2+
transient during activation of cardiac muscle cells (Cannell et al.,
1994
; Bridge et al., 1999
). Ca2+ sparks occur at the
location of t-tubules (Shacklock et al., 1995
; Cheng et al., 1996a
),
which is where the dyadic junctions between closely opposed transverse
tubular and sarcoplasmic reticulum (SR) membranes occur (Jorgensen et
al., 1993
; Soeller and Cannell, 1997
; Franzini-Armstrong et al., 1999
).
The discovery of these local events has helped to explain how cardiac
excitation-contraction coupling can exhibit high amplification of the
trigger Ca2+ influx across the sarcolemma without becoming
unstable (Stern, 1992
; Cannell et al., 1995
; Santana et al., 1996
).
Recent studies suggest that cardiac Ca2+ sparks arise from
the opening of a small number of SR release channels or ryanodine receptors (RyRs) (Bridge et al., 1999
; Lukyanenko et al., 2000
; Wang et al., 2001
). Because the fluorescence image of a
Ca2+ spark reflects the gating of RyRs in their native
environment, analysis of Ca2+ sparks can provide insight
into the regulation and gating of RyRs in situ. The magnitude of the SR
Ca2+ release flux underlying Ca2+ sparks is the
product of the number of RyRs present, their single-channel flux, and
their open probability and can be used to provide insight into these
variables (Cannell and Soeller, 1998
). For example, if just the
single-channel current is known, the minimum number of RyRs involved in
generating a Ca2+ spark can be estimated. If the number of
channels is also known (for a fixed spark site under steady-state
conditions), the open probability of the RyRs can be estimated.
Unfortunately, extraction of the Ca2+ release flux
underlying Ca2+ sparks is complicated by the recorded
fluorescence transient not being a direct measure of the SR release
flux. This problem arises from the diffusion and binding of
Ca2+ to the indicator (and other Ca2+ binding
species) and the low signal-to-noise ratio of the recorded Ca2+ spark. Although flux reconstruction methods have been
used to estimate SR release fluxes underlying sparks (Blatter et al., 1997
; Rios et al., 1999
) and analyze modulation of RyR gating (Lukyanenko et al., 1998
), a number of serious problems and
uncertainties remain. First, the ability to extract the release flux
underlying Ca2+ sparks has not yet been experimentally
tested. Second, it is known that significant dye binding to immobile
structures occurs in the cytosol (Harkins et al., 1993
) and a recent
study of Ca2+-indicator signals from muscle has shown that
a detailed model of indicator binding is required to explain the
experimental observations (Hollingworth et al., 2000
). Nevertheless,
all previous reconstruction procedures have been based on "simple"
dye binding models where the binding of the fluorescent indicator dye
to immobile intracellular structures was not considered in detail (but
approximated using a lower effective diffusion coefficient). A third
problem arises from the sensitivity of the flux reconstruction
algorithm to noise in the input data, which, in combination with the
noise associated with Ca2+ sparks records, renders
estimation of release fluxes problematic. Although averaging of
Ca2+ spark records could provide a way to improve the
signal-to-noise ratio of the input data, simply averaging from randomly
selected sites is complicated by the site-to-site variation in
Ca2+ spark properties (Parker and Wier, 1997
; Bridge et
al., 1999
). Finally, it is unknown whether the average reconstructed
release flux is proportional to the release flux reconstructed from an averaged Ca2+ spark (i.e., if the method is linear).
Without such linearity, the flux reconstructed from average sparks will
not reflect the flux underlying individual Ca2+ sparks.
In this study, we have tested some of the implicit assumptions of
previous flux reconstruction methods and have developed new methods
that are applied to sparks recorded with an averaging protocol. By
generating artificial Ca2+ sparks with known underlying
fluxes (with two-photon excited spot photolysis of caged
Ca2+, Soeller and Cannell, 1999b
) we have obtained the
first experimental test of a flux reconstruction method. In addition,
we have investigated how a more complicated dye binding model (Harkins
et al., 1993
) improves flux estimation. Our results highlight the
errors associated with an oversimplification of the processes shaping
the Ca2+ spark and suggest that the calculated time course
of release flux inactivation based on the conventional flux
reconstruction algorithm (Lukyanenko et al., 1998
) is in error (because
it depends on the amplitude of release flux). Our spark reconstructions
calculated with the new algorithm suggest peak fluxes of 7-12 pA,
suggesting that sparks must arise from clusters of >15 RyRs. Some of
these results have been presented in abstract form (Soeller and
Cannell, 2001
).
| |
METHODS |
|---|
|
|
|---|
Numerical modeling
A numerical model of Ca2+ sparks was used to
generate simulated fluorescence data for some numerical tests of the
flux reconstruction algorithms. To accurately model the binding of the
fluorescent indicator fluo-3 to Ca2+ and proteins
(Hollingworth et al., 2000
), the scheme suggested by Harkins et al.
(1993)
was used. This scheme accounts for dye binding to immobile
structures and the reduced apparent Ca2+ affinity of fluo-3
that is observed in intact cells. Figure 3 A shows the
binding scheme, and the various on- and off-rates are summarized in
Table 1 (adjusted from 16°C to 22°C
using a Q10 of 2, cf. Hollingworth et al., 2000
). Only the
protein-free fluo-3 (F3) and fluo-3-Ca complex (F3Ca) are free to
diffuse in this scheme. The value of the free diffusion coefficient
(DF3) was estimated from published values of the
diffusion coefficients of fluorescein and rhodamine 6G in water at
25°C (5.1 and 2.8 · 10
6 cm2/s,
respectively, (Ko et al., 1997
)). Assuming approximate spherical symmetry of the diffusing molecules and a van der Waals volume directly
proportional to molecular weight (Ko et al., 1997
) fluo-3 should be
1.37 and 1.2 times larger than fluorescein and rhodamine 6G,
respectively. Thus, DF3 should lie between 2.3 and 3.7 · 10
6 cm2/s in water. We
therefore assumed a value of 3 · 10
6
cm2/s for diffusion in water. Because the viscosity of the
cytosol is approximately twice that of a simple salt solution
(Kushmerick and Podolsky, 1969
) a value of 1.5 · 10
6
cm2/s was used for modeling and flux reconstruction in cell
experiments. The resulting reaction-diffusion equations for the
fluo-3-Ca complex (free and protein bound) are listed in the Appendix
(Eqs. A1 and A2), and corresponding equations describe the evolution of
Ca2+ free fluo-3 concentration.
|
The reaction diffusion equation for Ca2+ is given in Eq. A5
in the Appendix. Binding to various Ca2+ buffers in the
cytosol gives rise to a flux qbuf (Eq. A6), SR uptake causes an additional removal flux (qrem)
and the principal source of Ca2+ influx is the
Ca2+ release flux (qCa). With
first-order buffer reactions,
|
|
SR uptake was approximated according to the equation,
|
(1) |
4 Ms
1, m is 3.9 and
KD,SR is 184 nM (Bassani et al., 1994The Ca2+ release flux qCa time
course was either a step lasting for 10 ms or an exponentially decaying
function with a time constant of 7 ms. The amplitude of the release
flux was varied between 0.5 and 16.5 pA (see Results). The release flux
was spread uniformly over a spherical region 200 nm in radius
resembling the diameter of junctional diads in cardiac muscle (see
Langer and Peskoff, 1996
; Soeller and Cannell, 1997
).
The Ca2+ diffusion coefficient in the cytosol
(DCa) was 3 · 10
6
cm2s
1 to account for the higher viscosity of
the cytosol as compared to simple salt solutions (Kushmerick and
Podolsky, 1969
). All simulations were started from a uniform
equilibrium distribution of all species at a resting Ca2+
concentration of 100 nM. The model equations were implemented using
FACSIMILE (Chance et al., 1977
) on a uniform grid with spherical symmetry. The radius of the simulation space was 10 µm, with a grid
spacing of 67 nm.
Simulation of line scan images
Protein-bound and protein-free forms of the Ca-fluo-3 complex
were assumed to contribute equally to emitted fluorescence (Harkins et
al., 1993
). The contribution of Ca2+-free fluo-3 to
measured fluorescence was neglected because it fluoresces about 200 times less strongly than Ca-fluo-3 (Harkins et al., 1993
). Records of
normalized fluorescence (F/F0) were generated by
dividing the computed distribution of total fluo-3-Ca complex
([TF3Ca], see Eq. A3) by the equilibrium value calculated at the
resting [Ca2+]. Optical blurring by a confocal microscope
was simulated by convolving the calculated fluorescence distribution
with a point spread function (PSF) that was the product of Gaussians in
x, y, and z directions, respectively (where
z was chosen parallel to the optical axis). Gaussians with a
full width at half maximum (FWHM) of 0.4 µm in x and
y and 0.9 µm in z were chosen to mimic the
resolution that we routinely achieve in experiments (as measured with
subresolution fluorescent beads). Finally, line scan images (Cannell et
al., 1994
) were simulated by extracting the time course of blurred and
normalized fluorescence along a line located at a chosen distance to
the center of the calculated spark (to simulate possible out-of-focus recording).
Generation of artificial model sparks
Artificial "model sparks" with known underlying release
waveform were generated using two-photon excited-flash photolysis (TPEFP) of the Ca2+ cage DM-Nitrophen (Kaplan and
Ellis-Davies, 1988
). Solutions for flash photolysis were prepared in a
basic solution containing 140 mM KCl and 20 mM HEPES, pH 7.4. To this
solution 0.8 mM DM-Nitrophen (Calbiochem, Alexandria, Australia) and
100 µM Fluo-3 (Molecular Probes, Eugene, OR) were added.
CaCl2 was added to this solution to set the free
Ca2+ concentration to 100 nM. Illumination for two-photon
excitation was provided by a modelocked Ti:Sapphire (Ti:S) laser tuned
to a wavelength of 730 nm. After passing through a Pockels cell
(Conoptics, Danbury, CT) the light was coupled into a modified confocal
microscope (Zeiss LSM 410, Jena, Germany) and focused to a stationary
spot parfocal with the confocal image plane. The PSF of photorelease was determined by uncaging immobilized caged fluorescein-dextran (0.5 µm in plane and 1.4 µm axially; Soeller and Cannell, 1999b
). The
distance between the focus and the cover slip was ~20 µm to avoid
edge effects. Fluorescence changes during the spot photolysis were
monitored using the 488-nm line of an argon ion laser (Uniphase, San
Jose, CA) in the confocal line-scanning mode of the microscope. The
pinhole was set to a diameter of ~1.5 Airey units, resulting in a PSF
with an FWHM diameter of 400 nm in plane and 900 nm in the axial
direction. Accurate axial alignment between the photolysis spot
(near-infrared light from Ti:S laser) and the recording plane (488 nm
light from the Ar+ laser) was assured by adjustment of a
lens in the Ti:S beam path, which corrected longitudinal chromatic
aberration (Soeller and Cannell, 1999b
). During line-scan imaging, the
scan line either passed through the center of the photolysis spot
(in-focus recording) or was offset from the center by 600 nm
(out-of-focus recording). Flash intensities were kept low (<1 mW at
the sample) to prevent photobleaching of fluo-3 and cage depletion at
the site of photolysis (confirmed by the square dependence of released
Ca2+ on flash intensity). The fluo-3 fluorescence excited
by the stationary uncaging beam was negligible in comparison to that
excited by the 488-nm monitoring beam (<2%). Between 30 and 480 responses were averaged to improve the signal-to-noise ratio of
line-scan images of model sparks. Due to the two-photon nature of the
excitation process, the photolysis rate is expected to be proportional
to the square of the flash intensity. To measure the squared flash time
course (for comparison with the reconstructed release time course) we
also measured two-photon excited fluorescence in a dilute solution (100 µM) of fluorescein in response to flashes that were used to generate
model sparks.
Parameters for flux reconstruction from artificial sparks
Reconstruction of the fluxes underlying artificial sparks
generated by two-photon excited-spot photolysis of DM-Nitrophen required estimation of its binding and transport parameters. The diffusion coefficient of DM-Nitrophen (DDM) in
water was estimated as 4 · 10
6 cm2/s
using a similar procedure to that used to estimate
DF3 above. On and off rates for DM-Nitrophen
were 3 · 107 M
1s
1 and 0.144 s
1, respectively (Escobar et al., 1997
). The on and off
rates for Ca2+ binding to fluo-3 in the salt solution used
were 2 · 108 M
1s
1 and 150 s
1, respectively, resulting in a
Kd of 0.75 µM (similar to that determined by
Escobar et al., 1997
). Note that proteins were not present in our flash
solutions and DF3 was, accordingly,
3 · 10
6 cm2/s.
Implementation of flux reconstruction algorithms
The first method of reconstructing the SR Ca2+
release flux that was implemented was similar to that used by others
(Blatter et al., 1997
; Rios et al., 1999
). Three different algorithms
with two different fluo-3 binding schemes were implemented. Figure 1 shows an overview of the dye reaction
models underlying these algorithms. The first algorithm (called the
"simple binding algorithm" or SBA) corresponded to a simplified
fluo-3 binding scheme that takes fluo-3 binding to immobile structures
into account by using a lower apparent diffusion coefficient
(DF3,app) and changed binding rate constants (to
reflect the reduced apparent Ca2+ affinity resulting from
protein binding in the cytosol). Algorithms of the SBA type have been
used in previous studies (Blatter et al., 1997
; Lukyanenko et al.,
1998
; Rios et al., 1999
). The second algorithm (called the
"nonequilibrium binding algorithm" or NBA) was based on the
reaction scheme given by Harkins et al. (1993
, see also Fig.
3 A and Table 1). The NBA considers separate freely diffusing and protein bound forms of the indicator. Furthermore, the
kinetics of reversible protein binding was explicitly modeled. The
third algorithm (called the "fast binding algorithm" or FBA) was an
approximation to the NBA, which also considered freely diffusing and
bound forms of the indicator but additionally assumed that protein
binding was instantaneous as described by the respective dissociation
constants of the Harkins scheme (cf. Table 1). To test the
approximation of instantaneous protein binding used in the derivation
of the FBA spark, simulations were run using the nonequilibrium dye
binding model (corresponding to the NBA), and the binding ratios of
fluo-3 and fluo-3-ca to protein were calculated (i.e.,
[PF3]/([P][F3]) and [PF3Ca]/([P][F3Ca]), respectively). Using a release current amplitude of 10 pA and starting from a resting
[Ca2+] of 100 nM, both ratios remained within <4% of
their equilibrium values. The NBA and FBA were developed as part of
this work, and a detailed description is given in the Appendix.
|
All algorithms involve three main steps. First, an estimate of the distribution of Ca2+-bound fluo-3 was calculated from the normalized fluorescence data (F/F0). F/F0 was obtained by dividing the fluorescence transient by the resting fluorescence recorded before the spark. Next, the underlying Ca2+ distribution was computed (using Eqs. A9 (SBA) or A13 and A17-A19 when using the NBA and FBA, respectively). Finally, the Ca2+ release flux (qCa) was calculated using both the fluo-3-Ca complex data and the previously calculated Ca2+ distribution (according to Eq. A10 for the SBA or Eqs. A7 and A20 for the FBA and NBA). A more detailed description of the procedure is contained in the Appendix.
The calculation of the time course of [Ca2+] and
qCa required numerical derivatives of image data
with respect to time and space (cf. e.g., Eqs. A4 and A7). Numerical
derivatives were computed using standard finite differencing schemes on
a pixel-by-pixel basis when the input data was essentially noise free
(e.g., when using simulated data). The pixel spacing in time and space
was typically 1 ms by 0.15 µm, and time and space derivatives were estimated using backward and centered differences, respectively. Because numerical differentiation is very sensitive to noise in the
input data, filters were used to minimize noise amplification when
dealing with noisy experimental (confocal) input data. We used
Savitzky-Golay filters, a class of polynomial smoothing filters that
have been shown to be useful for smoothing and differentiating noisy
experimental data (Bromba and Ziegler, 1981
; Ziegler, 1981
; Press et
al., 1992
). These filters are characterized by the order of the
smoothing polynomial, and the width N of the filter (which is equal to the number of filter coefficients). For signals that have a
Gaussian shape, the optimal width of a Savitzky-Golay filter of order 4 is 1.72 times wider than the FWHM of the signal (Bromba and Ziegler,
1981
). With a typical spark width of ~2 µm and a sampling
resolution of 0.15 µm, the spark FWHM equals ~13.3 pixels and the
optimal N is thus ~23. We chose slightly weaker filtering to preserve more high-frequency content and a filter of order 4 and
width 19 was used in experimental reconstructions.
Because the line scan images only contain data along one spatial
dimension, an assumption was necessary to allow calculation of the
Laplacians in the diffusion/reaction equations. Assuming an
approximately spherically symmetric fluorescence distribution, we used
the Laplacian in spherical coordinates,
|
(2) |
|
(3) |
Numerical integration of diffusion equations during the reconstruction
procedure was performed using FACSIMILE. In some cases, the calculated
Ca2+ distributions were post-processed by a Gaussian
smoothing filter (FWHM 0.25 µm × 1.5 ms) before the release
flux was determined. Buffer species concentrations, binding parameters,
and diffusion coefficients used in the calculations were identical to
those described under Numerical Modeling. The reduced diffusion
coefficient DF3,app for the SBA was obtained
from the free diffusion coefficient DF3 by
reducing it in proportion to the mobile dye fraction (determined at
resting [Ca2+] from the Harkins scheme). On and off rates
of 0.8 · 10
6 M
1s
1 and 80 s
1, respectively, were used in the SBA reconstruction,
similar to values used in previous studies (Blatter et al., 1997
; Smith
et al., 1998
).
The total Ca2+ current (Ispark) was
computed from the reconstructed release flux qCa
by volume integration,
|
(4) |
Flux reconstruction by parameter fitting
An alternative approach to reconstructing the fluxes underlying
Ca2+ sparks is to fit a given model to experimental data by
adjustment of the parameters that define the model. If the fit of the
model converges to the experimental data, then, within the constraints of the model, we obtain an estimate of the release flux. The primary advantage of the parameter fitting algorithm (or PFA) is its decreased sensitivity to noise in the input data (because no explicit numerical derivatives need to be computed). The fitting procedure was initiated by starting a model simulation run with an appropriately chosen initial
SR Ca2+ release waveform (that reasonably reproduced the
experimental spark in terms of amplitude and width). The simulation
program compared the fluorescence time course of the computed spark to that of the experimental spark at each point of a regular sampling grid
over a period of 35 ms and computed a residual sum of squares of
differences. In subsequent runs, the parameters characterizing the
release waveform were varied to minimize the residual sum of square
differences until the best fit was obtained. This was indicated by a
reduction of the residual square error to within a range that was
expected based on the noise in the experimental data (using an
estimated accuracy of ~5% of the average spark data). The whole
fitting process was automated under control of the simulation package
FACSIMILE (Chance et al., 1977
) that was used to implement our spark
model as described in Numerical Modeling above. The release waveform
qCa was defined by seven adjustable parameters
I0, t1,
1, t2,
2,
0 and
s,
|
(5) |
was a function of the two parameters
0 and
s and could change linearly in time
when t > t1:
|
(6) |
|
(7) |
1, t2, and
2 this
function can assume approximately rectangular shapes and exponentially
decaying/rising time courses (see Results). The experimental input
sparks used as a fitting target were digitally deconvolved prior to
fitting (using an iterative maximum-likelihood algorithm as described
above) to remove the blurring by the microscope. The dye binding model
and parameter set (describing dye binding, Ca2+ buffering
and diffusion) used in the fitting process were identical to those used
with the NBA (see also Fig. 1).
Imaging of rat cardiac myocytes
Enzymatically isolated rat cardiac myocytes were prepared as
described elsewhere (Evans and Cannell, 1997
) in accordance with the
Guide for the Care and Use of Laboratory Animals published by the National Institutes of Health (NIH publication No. 85-23 1985).
Briefly, 250-g Wistar rats were killed by lethal injection of
pentobarbital (100 mg/kg) and hearts quickly mounted on a Langendorff perfusion system. After initial perfusion with a nominally
Ca2+ free solution (containing in mM: NaCl, 120; KCl, 5.4;
HEPES, 10; pyruvate, 5; glucose, 20; taurine, 20; pH 7.05 with NaOH) for 5 min 4 U/ml protease (Sigma type XXIV), 1 mg/ml collagenase (Worthington type II) and 100 µM CaCl2 were added. After
10-12 min of enzyme treatment, the ventricles were cut free and
chopped into small pieces. A series of triturations was performed using a wide-bore pipette. The resulting cell suspension was filtered through
gauze and diluted with solution containing 100 µM CaCl2. The free Ca2+ concentration was gradually increased to 2 mM, and the final cell suspension was stored at room temperature.
For line-scan imaging, cells were incubated with 5 µM of the AM form
of fluo-4 for 25 min at room temperature (20-22°C). The cells were
then placed in the basic solution with 2 mM CaCl2 and 10-20 µM of nifedipine. (The nifedipine concentration was adjusted to allow identification of well-separated spark sites.) The labeled cells in the nifedipine solution were placed in the chamber of a
confocal microscope (Zeiss LSM 410) that had a glass coverslip as its
bottom. To image repeatedly active spark sites, a protocol similar to
that used by Bridge et al. (1999)
was used. Trains of action potentials
were invoked by field stimulation at a frequency of 0.33 Hz. Indicator
fluorescence was excited using the 488-nm line of an argon laser and
detected between 510 and 550 nm (HQ filter, Chroma Technology,
Brattleboro, VT). Fifty confocal lines were acquired during each field
stimulation. The field stimulus was triggered after the first 10 lines
and the resulting Ca2+ transients were recorded during the
remaining 40 line scans. Line scanning was performed at the maximum
scan speed of 1.4 ms/line. The total exposure time was therefore 70 ms/stimulus, and trains of up to 100 stimuli could be recorded without
detectable cell damage. Images were stored to hard disk for off-line analysis.
Data analysis
Line-scan images were analyzed using custom routines written in IDL (Research Systems Inc, Boulder, CO). The fluorescence during the prestimulus period was averaged and used to calculate self-ratio images by dividing the recorded fluorescence transient by the resting fluorescence intensity. To compute average sparks, all line scan images of a stimulation series were displayed and those spark sites manually selected that gave rise to sparks that were well separated from neighboring sites (to avoid contributions from Ca2+ release originating at adjacent sites). After analyzing 30 individual experiments, three spark sites were found that would be suitable for full analysis. Although the stimulus occurred at a fixed time with respect to the start of the scan, sparks were activated with a jitter of 1-2 lines (that was presumably due to the latency of L-type channel opening). This jitter was removed by aligning the rising phase of sparks before averaging.
| |
RESULTS |
|---|
|
|
|---|
Flux reconstruction from model sparks
To critically test the ability of our flux reconstruction method to reconstruct the local release flux, we estimated the flux underlying artificial model sparks produced by TPEFP. Example line-scan images of model sparks generated by TPEFP in the DM-Nitrophen solution are shown in Fig. 2 A. The left-hand panel shows images recorded in response to a Ca2+ step release generated by switching the photolysis spot on for 10 ms. The right-hand panel shows responses to an illumination time course that resulted in a release spike, which decayed approximately exponentially with a time constant of 4 ms. Using the SBA (because no immobile buffers were present in the test solution) the underlying [Ca2+] distributions and Ca2+ release fluxes were calculated, and Fig. 2 B shows that the [Ca2+] reaches a concentration of ~1 µM in the center of the photolysis spot, similar to the [Ca2+] concentrations achieved during a cardiac Ca2+ spark. The reconstructed Ca2+ flux peak amplitudes were ~30 mM/s (Fig. 2 C). The time course of photolysis was measured by applying the same illumination waveforms to a solution of fluorescein and recording the resulting fluorescence time course (see Methods). Comparison of the reconstructed release time course with that measured by fluorescein shows good agreement in both cases (Fig. 2 D). Similarly, the release time course reconstructed with a variant of the PFA (that used a SBA-type dye-binding model) agrees well with the expected time course (Fig. 2 E). The fluxes calculated with the PFA were slightly larger than those calculated with the SBA. This was largely explained by the fact that the release region reconstructed with the PFA was slightly narrower (data not shown).
|
These results show that our reconstruction methods can distinguish between the square step and a spiked release waveform. In the case of the step-shaped release waveform, the effects of a lower signal-to-noise ratio (decreased by a factor of ~4) and out-of-focus recording were also tested (Fig. 2 D). Although the reconstructed release waveform was clearly more noisy when using the lower signal-to-noise input data, the general square step shape was still reproduced. Using slightly out-of-focus (600 nm) input data, the waveform was similar to that of the in-focus reconstruction but reduced in amplitude.
Numerical tests of flux reconstruction algorithms
A number of numerical tests of the performance of the flux
reconstruction algorithms were carried out. It is known that dye binding to proteins occurs in muscle cells (Harkins et al., 1993
) and
that it must occur reversibly with finite on and off rates (for
thermodynamic reasons). Therefore, the reversible dye binding model
underlying the NBA was used to generate the simulated sparks because it
reflects these dye properties most accurately (among the models used in
this study, cf. Fig. 1). Simulated fluorescence records were calculated
using a square step-release waveform corresponding to a release current
of 11 pA. For ideal conditions, the fluorescence records were not
blurred and represented an in-focus recording through the center of the
spark site. The results generated by the NBA were, as expected, in good
agreement with the simulated [Ca2+] release fluxes, as
shown in Fig. 3 B. The FBA (that used only the
experimentally observable concentration of TF3Ca) also produced reasonable time courses but with slightly increased amplitudes (Fig.
3 C). In contrast, estimates
produced by the SBA showed large discrepancies with regard to time
course, spatial distribution and amplitude of both [Ca2+]
(not shown) and qCa (Fig. 3 D).
These major errors occurred despite the fact that the effective
diffusion coefficient for fluo-3 in the reconstruction was reduced in
direct proportion to the level of dye binding to proteins (i.e.,
DF3 was reduced by a factor of 0.13 because 87%
of the dye was bound to protein). Because all previous studies have
used a modification of the diffusion coefficient (to mimic the effects
of dye binding) we suggest that, in general, the release flux will have
been underestimated. To mimic the PSF of our confocal microscope the
simulated fluorescence transient was blurred using a Gaussian-shaped
kernel (FWHM 0.4 × 0.4 × 0.9 µm in x, y, and
z, respectively). In the presence of optical blurring and
recording from a line that passed through the center of the spark
(in-focus recording, Fig. 3 E), the fast-binding algorithm
produced a release flux estimate that was spatially wider than the
underlying release region (~0.7 µm versus 0.4 µm). As might be
expected, the calculated peak flux amplitude was reduced (~8% of the
correct amplitude when using the FBA). However, the integral of the
flux was only slightly reduced when compared to the actual amplitude
(~8 pA versus 11 pA). The effects of blurring could be partly
restored by deconvolving the line-scan data prior to reconstruction.
Using the deconvolved data, the amplitude was restored to ~20% of
the correct one and the integrated current was nearly fully recovered
(~10 pA). The reconstructions generated by the SBA underestimated
peak flux and integrated flux more severely. When the input data was
further degraded by recording out-of-focus (600 nm from the center of
the spark site, Fig. 3 F) a further reduction in flux was
observed (~4 pA versus 11 pA for the FBA), which was only partially
recovered by deconvolution.
|
When model sparks with exponentially decaying release time courses were
modeled, the FBA reported that the release time course was sensitive to
the amplitude of the release function (Fig.
4 A). In Fig.
4 B, this artifact of the FBA is examined for release fluxes between 0.5 and 16.5 pA. Over this range, the calculated release
time constant varied between ~120% and ~80% of the actual release
function time constant (7 ms). When the SBA was applied to the same
data, the distortion of the calculated release time course was more
severe (compare Fig. 4 A and C with B
and D). For the smallest release flux (0.5 pA), the error
was small (~2%) whereas, for the largest release flux (16.5 pA), the
error increased so that the reconstructed time constant was only 37%
of the actual time constant (Fig. 4 D). These results
suggest that caution must be applied to the interpretation of release
waveforms calculated from Ca2+ sparks of different
amplitudes, a problem compounded by the use of the SBA. In connection
with this point, it has been suggested that large amplitude sparks are
associated with a faster decaying release flux (Lukyanenko et al.,
1998
).
|
To test for linearity in the relationship between the reconstructed release current amplitude and the actual current amplitude, release currents were calculated from simulated Ca2+ sparks with different release flux amplitudes. Blurring and a defocus of 600 nm was applied to the simulation data. The results are summarized in Fig. 5 A, which shows that the amplitude of the reconstructed release current is essentially proportional to the actual release current. However, the reconstructed release amplitudes systematically underestimate the true current by a factor of ~2.5 (without deconvolution) or ~2.2 (with deconvolution). This effect was due to the out-of-focus recording (see also Fig. 3 F). The effect of defocus is explored in Fig. 5 B. For no defocus, the FBA reports a peak release flux of 77% of the actual, and this figure decreased with increasing defocus to 15% at 1 µm when the raw blurred data was used as input. With deconvolution prior to reconstruction the peak release flux is restored to ~95% for an in-focus spark and decreases to ~16% at 1 µm.
|
The novel PFA was also tested in a numerical experiment. To demonstrate that the PFA can distinguish between abruptly terminating and more gradually decaying release waveforms, it was used to reconstruct the fluxes underlying two noisy simulated sparks. To simulate the photon noise in experimental spark records, Poisson noise corresponding to a signal of 150 photon counts at the peak of the fluorescent transient was added to the simulated spark data. Figure 6, A and B, show results of using the PFA to reconstruct the release flux underlying a spark that resulted from a fast rising and exponentially decaying release waveform. The reconstructed release flux (that resulted in the best fit to the noisy data) approximated the actual waveform well (Fig. 6 B). Note that the release flux reconstructed from the same data using the FBA was more noisy. A second simulated spark that was generated using a nearly rectangular-shaped release waveform was also well fit with the PFA (Fig. 6 C). Figure 6 D shows that the reconstructed release flux reproduced the abrupt onset and termination of release (albeit with slightly increased rise and fall times). Notably, the reconstructed fluxes calculated with the PFA were largely unaffected by the noise in the simulated spark records.
|
These results suggest that the FBA and the PFA (but not the SBA) can
provide a good estimation of actual release currents. As noted above, a
problem in reconstructing the fluxes underlying Ca2+ sparks
is the generally poor signal-to-noise ratio associated with their
recording. Reconstruction tests using records of individual sparks
suggested that the reconstruction algorithms are so sensitive to noise
as to render the reconstructed flux distribution almost useless (data
not shown). This was the case for previously published (SBA) and
algorithms developed in this study (NBA, FBA, PFA). To ameliorate this
problem, we can apply signal averaging to Ca2+ sparks
recorded from well-separated, individual Ca2+ spark sites
(Bridge et al., 1999
). This protocol allows reconstructing the average
release waveform at a fixed spark site at steady state. Although it has
been suggested that individual Ca2+ spark sites respond in
a stereotypical way (Bridge et al., 1999
), it is possible the release
flux time course could vary between individual Ca2+ sparks.
Although Fig. 5 A suggests that the FBA reconstructed flux
amplitude scales in proportion to the underlying flux, we also tested
whether the release flux computed from the averaged Ca2+
spark was the same as the average of fluxes from the individual Ca2+ sparks. Figure
7 A shows ten simulated
sparks where the release waveform deviated randomly from a mean
waveform. The time of the upstroke of the underlying step release was
exponentially distributed with a mean of 1.5 ms, and the duration of
the release step varied exponentially with a mean of 3 ms.
Additionally, the amplitude of the release current during the plateau
deviated from a mean of 11 pA according to Poisson statistics with a
standard deviation of 1.1 pA. The individual release time courses and
the average release waveform are shown in Fig. 7 B. The
Ca2+ distribution (Fig. 7 C) and release flux
(Fig. 7, D and E) reconstructed from the average
spark agree very closely with the averaged Ca2+
distribution and the averaged release flux, respectively. This suggests
that the flux reconstruction procedures behave approximately linearly
and the release flux reconstructed from average sparks at a fixed site
will correspond to the average release flux at that site.
|
Experimental average sparks at fixed sites and flux reconstruction
The above tests suggest that the FBA and the PFA can provide an
estimate of the release waveform associated with Ca2+
sparks, and that averaging to improve signal-to-noise does not seriously distort the average release flux. Figure
8 A shows ten line-scan
images (from a sequence of 100) and evoked Ca2+ sparks in
response to the electrical stimulation are clearly visible. Several
repeatedly firing sites can be seen, and individual line-scan images
from the sequence were selected on the basis that no adjacent sites
appeared to be active (Fig. 8 B). Note the stereotypical
appearance of these sparks with regard to amplitude and spatial extent
in these images, supporting the idea (Bridge et al., 1999
) that
individual spark sites appear to respond in an all-or-none fashion.
Figure 8 C shows the spatio-temporal properties of the
resulting Ca2+ spark obtained by averaging the individual
Ca2+ spark records. The averaged Ca2+ spark was
associated with a peak fluorescence ratio of 3.5 and a spatial extent
of ~1.7 µm (FWHM) at the peak. These properties are within the
range reported elsewhere (Cheng et al., 1996a
; Song et al., 1997
).
|
Figure 9 shows flux reconstructions from three individual Ca2+ spark sites. The upper panel shows the averaged Ca2+ sparks (Fig. 9 A), and the calculated release wave forms using the FBA are shown below (Fig. 9 B). Despite averaging, noise in the reconstruction is large, and, without averaging, the computed waveform would probably be useless. Because the deconvolution increased noise in the reconstructed release waveform (data not shown), the FBA calculations were performed on the raw data. Figure 9, C and D, shows the deconvolved average sparks and the best-fit sparks determined with the PFA, respectively. The release currents (integrated within a radius of 0.7 µm) that were calculated with the FBA and the PFA are compared in Fig. 9 E, and peak amplitudes ranged from 7 to 12 pA. The time courses calculated with the FBA and the PFA are in reasonable agreement with respect to rise time and peak amplitude, although the traces calculated with the FBA are generally more noisy. The release currents calculated with the PFA decay approximately exponentially. This point is explored further in Fig. 10, which shows PFA reconstructions of the release flux at the center of the three averaged sparks. Although the amplitudes of these sparks were variable, the time constants of decay of the release flux were all within the range ~7-8 ms.
|
|
Because the calculated Ca2+ release flux also depends on the values of the various parameters (describing binding and movement of the various species), we performed a sensitivity analysis. The release flux from one of the sparks shown in Fig. 9 was reconstructed using a number of parameter sets in which individual parameters deviated by a factor of 1.5 from our standard parameter set (see Methods). The resulting time courses of Ca2+ release flux and integrated current were generally unaffected, but the calculated current amplitudes varied depending on the parameter set. When the fluo-3 affinity was reduced by 50%, the calculated current was increased to 17.2 pA or ~160% of the value calculated with the standard parameter set. A 50% increase in fluo-3 Ca2+ affinity resulted in a reduction of the estimated amplitude to ~70%. Changes in the resting Ca2+ concentration caused similar changes in the estimated current amplitude (to 170 and 62% when the concentration was increased or reduced by 50%, respectively). We additionally tested the effect of similar changes in DF3, DCa, total troponin and fluo-3 concentration, and kinetics of fluo-3 binding. The resulting changes in current amplitude were less than 20%.
| |
DISCUSSION |
|---|
|
|
|---|
In this study, we have tested the ability of four flux
reconstruction algorithms to reconstruct local Ca2+ fluxes
from confocal line-scan images and identified two algorithms that can
provide useful measurements of the Ca2+ release fluxes
underlying Ca2+ sparks in rat cardiac myocytes. By using
artificial sparks, we provide evidence that our flux reconstruction
algorithms produce reliable estimates of the underlying
Ca2+ fluxes. We have also shown that detailed modeling of
dye binding to immobile structures is required for accurate
reconstruction, in accord with the conclusions of Hollingworth et al.,
(2000)
. Failure to account for dye movement can lead to serious
artifacts in flux reconstruction, the most serious of which is a
strongly amplitude-dependent time course. Because such a
phenomenon has been reported, we suggest that such data need to be
re-evaluated using our FBA or PFA. Using these reconstruction
algorithms, we have estimated that the release fluxes underlying
Ca2+ average sparks in rat cardiac myocytes are 7-12 pA in
amplitude and last ~10 ms.
Experimental tests of the flux reconstruction algorithm
Although flux reconstruction algorithms have been derived from
theoretical models of spark formation (Blatter et al., 1997
), the
present study provides the first direct test of such methods in an
experimental model. To generate artificial Ca2+ sparks with
known release waveforms, we used the unique ability of two-photon
excited flash photolysis to create a local source of Ca2+
by photolysis of DM-Nitrophen. Although the region of photorelease was
not spherical (but rather the ellipsoidal shape of the microscope PSF)
the resulting fluorescence distribution should rapidly become spherical
as diffusion takes place. The Ca2+ release time course
underlying these artificial sparks is known because the rate of
photolysis is proportional to the time course of the squared flash
intensity (provided the intensity is well below saturating levels, as
was the case here
data not shown). It was therefore possible to
directly compare the calculated release waveforms to the known release
waveform to test the reliability of the algorithms. To our knowledge,
this is the first time that any such test of flux reconstruction
algorithms has been performed.
To make our tests realistic, we produced artificial sparks, which
resembled experimentally recorded Ca2+ sparks in terms of
size, duration, fluorescence amplitude, and signal-to-noise ratio. The
latter factor is particularly important because all inverse
reconstruction algorithms (i.e., those that use differentiation) are
extremely sensitive to noise. In fact, even with signal averaging, the
resulting computed spark release waveform was quite noisy, and, without
averaging, would have been useless. Although the PFA is less noise
sensitive than other inverse reconstruction algorithms, signal
averaging is still important to constrain the fitted release flux
distribution. An additional complicating factor resides in the problem
that the exact locus of the origin of the spark is unknown. It was
therefore of interest to examine the sensitivity of the reconstructed
waveform to small amounts of microscope defocus (Izu et al., 1998
). We
found that, as defocus increased, the reconstructed flux decreased in
amplitude with minimal changes of the time course (Fig. 2). It follows
that our reconstructions of evoked Ca2+ sparks must be a
lower limit of the actual release flux, although the release waveforms
should be reasonably accurate.
Reversible dye binding and flux reconstruction
Experimental observations suggest that a significant proportion of
fluo-3 (>80%) is bound to immobile structures in the cytoplasm (Harkins et al., 1993
). In models of Ca2+ spark formation,
the effect of dye binding is generally approximated by reducing the
effective fluo-3 diffusion coefficient in proportion to the estimated
bound fluo-3 ratio (e.g., Pratusevich and Balke, 1996
; Smith et al.,
1998
). Such an approach is justified if the binding kinetics are
instantaneous and there are no differences in affinity between bound
and free forms, and previous studies have used this simplifying
approximation (Blatter et al., 1997
; Lukyanenko et al., 1998
; Rios et
al., 1999
). We found that a simplified dye binding model (SBA) does not
correctly reconstruct the release time course, although optical
blurring by the microscope helped reduce the reconstruction error of
the SBA (albeit at the expense of a reduced reconstructed flux
amplitude, Fig. 3). Prompted by the generally poor performance of the
SBA, we developed novel algorithms (the FBA and the PFA) that are based
on improved approximations to the Harkins (1993)
scheme. The idea that
SBA models are inadequate is supported by the observation of
intrasarcomeric Ca2+ movements in skeletal muscle, which
require a more detailed model of dye binding to explain them
(Hollingworth et al., 2000
). Even in the presence of optical blurring
and out-of-focus recording, the FBA reconstructed time course matched
the actual time course reasonably accurately, although the peak
amplitude was reduced by de-focus and blurring.
Dye binding schemes
We examined three different approaches to account for dye binding.
The simplest class of model (SBA) assumes that dye binding can be
modeled by a reduction in dye diffusion coefficient. As described
above, such models do not adequately describe either the time course or
amplitude of the release flux. Even more serious is the fact that the
models produce a release flux time course that is strongly amplitude
dependent. Clearly, such an artifact would be unacceptable for classes
of experiment which seek to relate the time course of RyR inactivation
to the amplitude of the Ca2+ release flux (Lukyanenko et
al., 1998
). The next class of model would explicitly deal with
protein-bound and free forms of the dye and assume instantaneous
equilibration between bound and free forms. We examined this FBA model
and showed that it was able to reproduce known release waveforms with a
reasonable degree of accuracy. A more complete model also includes the
kinetics of the dye-protein interaction. This NBA model was also good
at flux reconstruction, but was not markedly better than our FBA method. However, the NBA cannot be used to reconstruct fluxes underlying experimental sparks because it requires the (nonobservable) calcium-free fluo-3 as input. We have overcome this limitation with the
novel PFA, a fitting algorithm that uses the full binding model
(including dye-protein binding kinetics) and is also less sensitive to
noise in the input data.
Flux reconstruction from average sparks
Ca2+ flux reconstruction from individual experimental
sparks records is problematic due to the generally low signal-to-noise ratio. Averaging spark records provides, in principle, a useful way to
improve the signal-to-noise ratio. Because the FBA contains nonlinear
steps (e.g., Eq. A13) it was necessary to show that the FBA behaved
linearly with respect to averaging, and that this was the case was
demonstrated in Fig. 7. We electrically evoked sparks and selected
well-separated, repeatedly firing spark sites. To obtain such
well-defined sites, the probability of Ca2+ spark
occurrence is reduced by a Ca2+ channel blocker, such as
nifedipine, which does not alter the properties of Ca2+
sparks (Collier et al., 1999
). In addition, sites chosen for averaging
must not be contaminated by release events from nearby sites; this
strict criterion resulted in <10% of experiments yielding sites for
further analysis. Furthermore, we viewed it to be important to select
sparks that were at least as large (F/F0 > 2.5) as the average spark amplitude to ensure that the site was
close to the line scanned by the confocal microscope (Pratusevich and
Balke, 1996
; Izu et al., 1998
; Cheng et al., 1999
). From consideration of our selection criteria (selecting from the brightest 25% of sparks), we estimate that the sparks analyzed here should have been, on
average, ~0.25 µm from the scan line (Izu et al., 1998
). We
therefore predict that we underestimate the true current amplitude by a
factor of ~1.4 (see Fig. 5 B). In contrast, sparks have
been shown to be larger in the longitudinal direction by ~18% (Cheng et al., 1996b
). Because we recorded sparks in the longitudinal direction and assumed a spherical fluorescence distribution, we would
have overestimated the current by a volume factor of 1.182
or ~1.4. This analysis suggests that these two effects, taken together, compensate each other, and our calculated current amplitudes should be a reasonable estimate of the underlying release fluxes.
By averaging >9 individual Ca2+ sparks, the improved
signal-to-noise ratio allowed the FBA and the PFA to produce an
estimate of the amplitude and time course of the Ca2+
release flux underlying these sparks. The FBA and PFA reconstructed release current time courses were similar with regard to rise time
(4-5 ms) and peak amplitude (7-12 pA). Although the currents calculated with the PFA decayed approximately exponentially, the traces
calculated with the FBA seemed to terminate more abruptly. We suggest
that this can be largely explained by the noise sensitivity of the FBA
because we observed a similar effect when the FBA was used to
reconstruct a noisy simulated spark arising from an exponentially decaying release waveform (Fig. 6 B). Comparison of the
release time course of the three average sparks that were analyzed
suggested that the decay times were very similar, although the
amplitudes of these three sparks were quite different (Fig.
10 A), in contrast to the results by Lukyanenko et al.
(1998)
.
It is also important to note that our spark model reproduces the
spatial dimension of Ca2+ sparks, which has been a
deficiency in all previous spark models. This improvement was achieved
by allowing the region of release to grow with time during the period
of release. Such an effect could be reasonably explained by recruitment
of RyRs from the site of initiation during the early phase of a spark
evolution. Indeed, electron micrographs of couplons show them to be
quite extended (Franzini-Armstrong et al., 1999
).
It is notable that the SR release flux of 7-12 pA is more than twice
as large as that estimated by Cheng et al. (1993)
and Blatter et al.
(1997)
. When comparing local flux densities, our estimate of ~50 mM/s
is five times larger than that reported by Blatter et al. (1997)
and
nearly an order of magnitude larger than that estimated by Lukyanenko
et al. (1998)
. We suggest that the previous studies underestimate the
fluxes underlying the spark for several reasons: 1) the use of
extensive filtering to suppress noise (Lukyanenko et al., 1998
); 2) the
use of SBA-type approaches (Blatter et al., 1997
; Lukyanenko et al.,
1998
); and 3) low values for the fluo-3 binding constants (Cheng et
al., 1993
; Blatter et al., 1997
; Lukyanenko et al., 1998
). In a recent
study that sought to explain the spatial dimensions of Ca2+
sparks, a lower estimate of ~11 pA was obtained (Izu et al., 2001
),
which agrees reasonably with our estimates. However, the same study
suggested that the current underlying a Ca2+ spark could be
as large as ~40 pA, which would be associated with abnormal spark
amplitudes (F/F0
12). Our estimate is
approximately five times larger than that estimated by calibrating
spark amplitude with local fluorescence changes produced by
dihydropyridine receptor (DHPR) gating (Wang et al., 2001
). A part of
this difference resides in the spark amplitudes being larger in our
experiments. Additionally, it is possible that the site from which the
DHPR current was recorded was some distance from the spark site in the
experiments of Wang et al. (2001)
. This idea is supported by their
observation of an abnormally long delay between DHPR opening and spark
activation and a relatively low coupling efficiency, despite the
(drug-induced) long DHPR open times in their study.
Given an SR release flux of >7.5 pA, we can estimate that at least
~15 RyRs must be activated during a Ca2+ spark (for a
single RyR current of ~0.5 pA, Mejia-Alvarez et al., 1999
). Because
this cluster of RyRs opens within ~4 ms, we can estimate that the
opening rate constant must be ~500/s (if 4 ms equals two time
constants) which, if Ca2+ gated, implies a local trigger
level of ~10 µM for a diffusion-limited on rate of 2 × 108 M
1s
1. This estimate of the
local trigger Ca2+ is in good agreement with previous
detailed mathematical modeling of the dyadic cleft (Cannell and
Soeller, 1997
; Soeller and Cannell, 1997
) and an analysis of the
increase in spark rate during excitation-contraction coupling (Cannell
et al., 1994
). By examining ruthenium red inhibition of RyRs it was
estimated that >10 RyRs should be involved in a Ca2+ spark
(Lukyanenko et al., 2000
). Using a different approach, Bridge et al.
(1999)
estimated that at least 19 RyRs were activated during a
Ca2+ spark, in reasonable agreement with our results. To
achieve the activation