| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |


* Botanisches Institut I, Universität Karlsruhe, Karlsruhe, Germany;
Institut für Pflanzenphysiologie, Universität Salzburg, Salzburg, Austria; and
Department of Cellular and Molecular Physiology, Yale School of Medicine, New Haven, Connecticut
Correspondence: Address reprint requests to Hermann Bihler, Botanisches Institut I, Universität Karlsruhe, Kaiserstrasse 12, 76128 Karlsruhe, Germany. Tel.: 49-721-608-6887; Fax: 49-721-608-4193; E-mail: db49{at}rz.uni-karlsruhe.de.
| ABSTRACT |
|---|
|
|
|---|
pH) across the vacuolar membrane, being
2H+/ATP at high
pH (4 pH units) and increasing to >4H+/ATP for small or zero
pH. That result is in quantitative agreement with previous determinations on plant vacuoles. Considerations of purely electrical behavior, together with the physical properties of a recent detailed structural model for V-ATPases, led to a linear equivalent circuitwhich quantitatively accounts for all observations of variable coupling ratios in fungal and plant V-ATPases by variations of the conductance for bona fide proton pumping (GP) through the ATPase relative to independent proton shunting (GS) through the same protein. | INTRODUCTION |
|---|
|
|
|---|
Vacuolar membranes, like most other organellar membranes and all cellular plasma membranes, carry out three types of solute transport: 1), primary active transport, i.e., enzyme-like carriers (or pumps) conduct thermodynamically uphill movement of ions driven by a primary energy source (e.g., light, redox energy, ATP or pyrophosphate); 2), secondary active transport, i.e., uphill movement of one species is directly coupled to the downhill movement of another; and 3), strictly passive transport, i.e., downhill movements only, which are mediated either by pores/channels in the membrane, or by carriers that are not coupled to metabolic free energy.
Within this hierarchy, it is ultimately primary active transport which provides the energy for secondary active transport, and restores the gradients dissipated by strictly passive transport. In plant and fungal vacuolar membranes, there are two types of proton pumps operating via primary active transport mechanisms, one of which extracts energy from the hydrolysis of pyrophosphate (the so-called H+-PPase), and the other from hydrolysis of ATP (the so-called V-ATPase). The tonoplast of Saccharomyces cerevisiae does not contain an H+-PPase, but only a V-type H+-ATPase, which is defined in genetic and molecular terms. This V-ATPase transports only protons, without coupling to other ions, thus transferring one net charge from cytoplasm to vacuolar lumen for each proton pumped into the vacuole (Nishi and Forgac, 2002
). Consequently, the yeast V-ATP-ase normally develops both a trans-tonoplast difference of electric potential (cytoplasm negative) and a trans-tonoplast difference of pH (cytoplasm alkaline).
If the pump is tightly coupled and if parallel ionic conductivities are negligible, the relationship among the equilibrium voltage, Ep, i.e., the electromotive force (EMF) of the pump, the proton concentrations on the two sides of the membrane, and the energy from hydrolysis of ATP can be derived from the mass reaction equation for the overall pumping process as
![]() | (1) |
![]() | (2) |
For a tightly coupled reaction (Eq. 1) and neglecting parallel ionic pathways, EP should equal the measured reversal voltage, ER, the voltage at which membrane current is zero. Then, the coupling ratio (n) of the V-ATPase reaction can be calculated from Eq. 2 as
![]() | (3) |
![]() |
![]() |
|
The experimental data from yeast tonoplasts generally confirm the earlier findings on lemon, beet, and other plant vacuolar membranes, but considerations of the nature of the data from which variable coupling ratios are deduced, for the V-ATPases, suggests a straightforward and physically simple interpretation: namely, proton shunting through the pump mechanism, whichbecause of the usual direction of the electrochemical gradientwould flow predominantly in the reverse direction through the pump. This proton flux would depend upon the presence of ATP, since V-ATPases deprived of ATP do not leak protons (see Grabe et al., 2000
), but would not be coupled either to ATP synthesis or to ATP hydrolysis.
| MATERIALS AND METHODS |
|---|
|
|
|---|
Experiments were started under symmetrical ionic conditions, in which the pipette solution (for the vacuole interior) was the same as the bath solution (replacing cytoplasm), and with continuous perfusion of bath solution through the recording chamber. Starting solution (standard bath medium), contained 150 mM KCl, 5 mM MgCl2, 0.5 mM EGTA, and 5 mM MES titrated to pH 7.5 with Tris base. ATP, ADP, and Pi (inorganic phosphate) were added to the bath solution as potassium salts, and KCl was diminished to keep the total bath K+ concentration constant. Bath solution supplemented with ATP alone (ATP medium) contained 5 mM K2-ATP and 140 mM KCl plus the other salts, and bath solution supplemented with ATP/ADP/Pi (AAP medium) contained 5 mM K2-ATP, 5 mM K-ADP, 10 mM KH2PO4, and 125 mM KCl plus the other salts.
Recording and analysis
Patch-recording was carried out with an EPC-9/ITC-16 amplifier and data acquisition system (HEKA, Lamprecht, Germany). Data were accumulated at 10 kHz, filtered at 100 Hz, and sampled either at 1 kHz (for I-V analysis) or at 30 Hz (for continuous current recordings), then stored to the computer hard drive. Steady-state current-voltage recordings were made in the whole-vacuole configuration, using linear voltage ramps of 5 s duration running from a membrane voltage (Vm) of -80 mV to +80 mV, and the corresponding whole-vacuole currents were measured.
Current-voltage (I-V) curves describing the characteristics of the V-ATPase were obtained by subtracting each I-V curve for a nonenergized membrane (without ATP) from the corresponding I-V curve for the energized membrane (ATP added); or (as shown previously by Kettner et al., 2003
), in the continued presence of ATP by blocking the V-ATPase with bafilomycin, and subtracting the resulting I-V curve from the unblocked control. Under these experimental conditions, Mg-ATP does not induce any spurious ionic currents or conductances in yeast tonoplasts, so the reported difference I-V curves do indeed characterize the yeast V-ATPase itself. Also, Mg-ATP is not a limiting factor in our experiments, since the pump KM value for Mg-ATP is
50 µM (Kettner, 1999
) and the experimental free Mg-ATP concentration is between 1.8 and 3.3 mM, depending on the cytosolic pH (see Table 1).
However, to compare I-V data from vacuoles of different sizes and to obtain averaged curves from all of those actually measured under any one condition, the I-V plots shown were scaled to current densities (mA/m2), by dividing each vacuole-membrane area into the corresponding measured currents. Membrane areas were determined from capacitance measurements on each tonoplast, assuming a specific membrane capacitance of 1 µF/cm2 (standard for most biological membranes). Measured capacitances ranged from 2 to 7 pF, implying membrane areas of 200700 µm2.
The sign convention proposed by Bertl et al. (1992)
for tonoplast voltage and current was used throughout; i.e., the vacuole interior was treated like the cell exterior, and tonoplast voltage was calculated as cytoplasmic potential minus vacuolar potential.
| RESULTS |
|---|
|
|
|---|
5 min before the trace of Fig. 1 A, with the standard bath solution. With the membrane voltage clamped to zero the baseline or reference current (short-circuit current) was neglectable. When AAP medium was flushed through the chamber, current rose to
4 pA, then declined to the baseline upon washout with standard bath solution. After 1 min of washing, ATP medium was flushed through the chamber and the same pattern of short-circuit current was repeated, except that the maximal current was
9 pA instead of 4 pA. The direction of the current, upward or positive by the standard convention (Bertl et al., 1992
|
9 µm in diameter), and are plotted (black traces) against the clamped voltage. In Fig. 1, B and C, the difference I-V curves, gray traces ab and cb, define the current-voltage relationships for the V-ATPase in the two different media, ATP and AAP. It was shown previously (Kettner et al., 2003
-
for [ADP] and/or [Pi] = 0; see Eq. 2). But with the ATP/ADP/Pi mixture, ER fell at
-20 mV. Thus, although no attempt was made to measure actual ATP synthesis, it was clear that current could be driven either inward or outward through the V-ATPase, depending upon what voltage was imposed on the tonoplast. Fig. 2 displays results from one out of three experiments designed explicitly to demonstrate reversed current through the H+ pump. Cytoplasmic pH was set at the usual value of 7.5, and vacuolar pH (pipette solution) was set at 3.1, thus exerting a diffusional force (EH) equivalent to 260 mV directed toward the cytoplasm. With the vacuolar membrane voltage clamped to zero, when cytoplasmic standard medium was replaced by AAP, a current of nearly 5 pA flowed into the cytoplasmthe reverse direction for the pump, as shown by the downward shift of the trace in Fig. 2 A. This inward current was steady for almost 3 min, until AAP was flushed out of the chamber, which brought the pump current back to the baseline.
|
Coupling ratio versus stoichiometry
The structures of V-ATPases are now sufficiently well-known (see Finbow and Harrison, 1997
; Grabe et al., 2000
; Grüber et al., 2001
; Nishi and Forgac, 2002
; Arata et al., 2002
) that an ideal stoichiometry of operation can be specified: each 360° turn of the rotor carries six proton-transfer sites past three ATP-hydrolytic sites, so that two protons should be pumped for each ATP molecule split. Several reports in the literature have confirmed a stoichiometry of 2 for the vacuolar ATPase, e.g., in red beet (Bennett and Spanswick, 1984
; Schmidt and Briskin, 1993
), but more recent reports have appeared of 3, 4, or even more protons being transferred for each ATP hydrolyzed (Davies et al., 1994
; Yabe et al., 1999
; Müller and Taiz, 2002
), depending on membrane voltage and on ion concentrations at both sides of the membrane. These results have forced general use of the operational term coupling ratio, to refer to measurements of H+/ATP, rather than to the structural inferences. And indeed, it is the coupling ratio, not the ideal stoichiometry, which reflects the internal dynamics of the pumping process.
From Eq. 3, ERthe EMF which the V-ATPase can generatemust decline as the ratio of protons transferred per ATP molecule split (n) increases; or else n must increase as the measured reversal voltage approaches EH.
Obviously, however, the necessary calculation of (n) can be carried out via Eq. 3 only when ER can be determined experimentally and when all of the chemical concentration terms are known: namely, [ATP], [ADP], [Pi], and [H+] at the cytoplasmic surface of the tonoplast (chemically reactive side of the ATPase), and [H+] at the vacuolar side: in Fig. 1 A, for the first and third current peaks, obtained in AAP medium; but not for the second current peak, obtained with ATP only.
pH dependence of the I-V characteristic
We therefore carried out a series of patch-clamp experiments, analogous to those of Fig. 1, on isolated yeast vacuoles which were specifically energized by fixed concentrations of ATP, ADP, and Pi (see Materials and Methods) and beset with a range of pH values, both cytoplasmic and vacuolar. The resulting averaged difference I-V curves, representing explicitly the behavior of the V-ATPase, are plotted in Fig. 3. For Fig. 3 A, vacuolar pH (pipette solution) was held at 5.0, and cytoplasmic pH (bath solution) was varied from 5.0 to 8.5. Well-determined values of ER emerged for the three higher cytoplasmic pH values: -59.8 mV, -34.0 mV, and -17.5 mV, respectively, for pHC = 6.0, 7.5, and 8.5. For Fig. 3 B, cytoplasmic pH was held at 7.5, and vacuolar pH was varied from 7.5 to 4.1. Well-defined values of ER emerged for the two lower pH values: -38.6 mV and -25.6 mV, respectively, for pHV = 6.0 and 4.1. In both cases with zero pH difference across the tonoplast (a traces), ER could not be determined, but clearly lay negative to -80 mV, the largest negative voltage which could reliably be sustained without membrane breakage.
|
pH increased. The apparent saturation of current at high membrane voltages (+ or -) is most likely the consequence of rate limitation by chemical reactions, such as substrate binding and/or release (i.e., of ATP, ADP, Pi, or protons), rather than by voltage-dependent membrane-transit reactions (Hansen et al., 1981
pH dependence of ER and n
To actually calculate n from the measured ER it is necessary to know not only the concentrations of protons, ATP, ADP, and Pi, but also KATP or the standard free energy for ATP hydrolysis (
G0) under the different conditions of these experiments. Reasonable approximations can be obtained from the classic work of Alberty (1968)
, along with calculations of the corresponding free Mg2+ concentrations and ionic strength (Föhr et al., 1993
). The necessary information is set out in Table 1.
The results in Fig. 3, the experimental concentrations, and the values of KATP in Table 1 were applied to Eq. 3 to calculate the corresponding values of n, which are shown in Table 2 and plotted (solid circles) in Fig. 4. These numbers from the yeast vacuole are also compared with the previous results of Davies et al. (1994)
from red beet vacuoles (unfilled squares in Fig. 4). The overall plot, which has been fitted by a simple regression line, demonstrates two remarkable facts: 1), the current-voltage behavior of the V-ATPase in yeast tonoplast is essentially identical with that previously described in red beet tonoplast; and 2), the empirical relationship between the coupling ratio (n) and the pH difference across the vacuolar membrane, (pHCpHV), is linear for at least four units of
pH, and does not depend on either the vacuolar pH or the cytoplasmic pH, individually.
|
|
0.7 (H+/ATP) per
pH unit for both preparations, and the excellent agreement between the two indicates a high degree of conservation of V-ATPase function between plants and fungi. At the highest practical
pH (45 units), n was
2 H+/ATP, very close to the ideal stoichiometry expected from structural data (Finbow and Harrison, 1997
pH = 0, as indicated by the extrapolated line (dashed) in Fig. 4.
Interpretation of variable coupling ratios: noncoupled ion movements
As was discussed above, the ideal stoichiometry which can be inferred for V-ATPases, based on structural information, is 2 H+ ions transported for each ATP molecule split. The ideal stoichiometry, now represented generally as N, apparently equals the calculated n for large values of
pH (
4), in both the yeast V-ATPase and the red beet V-ATPase, as demonstrated in Fig. 4. Measured deviations from the ideal stoichiometry, for many different pumps and transporters, as well as for V-ATPases, have frequently been referred to as slip, usually meaning that one-half of the implied reaction couple of Eq. 1 can occur without the other half. That definition was explicitly broadened by Grabe et al. (2000)
, in a detailed physical-chemical model for V-ATPases, to include possible half reactions and total bypass for protons, which they termed proton slip flux. According to Grabe et al. (2000)
, proton slip flux includes 1), flux of protons that enter the rotor sites from the basic reservoir, make a full 360° turn, and dissociate back into the basic reservoir. This proton slip flux, i.e., J1, is not associated with a net charge transport; and 2), "a leak flux of protons (J2) shuttled by rotor sites that fluctuate between the output channel and input channel." This flux carries a downhill proton current.
Both to avoid confusion with these more complicated ideas, and to associate our elementary model with its electrical properties, we have attached the term proton shunt to the mechanism that seems likely to underlie variable coupling ratios in the V-ATPase.
Referring to Eq. 3 above, it is clear that any process in the vacuolar membrane which moves ER toward EH should elevate the calculated value of n. Such a process could, in principle, be unrelated to the V-ATPase, but the design of these experiments implies that such a process must be part of the V-ATPase chemistry, because the difference I-V curve from which ER was obtained reflects only the pump I-V characteristic. That is, shutdown of the pump by ATP removal gave exactly the same result as shutdown by blockade with the specific inhibitor bafilomycin (Kettner et al., 2003
). Then the calculated difference between the coupling ratio (n) and the ideal stoichiometry (N), nN, would represent the shunted proton flux, or better designated, the shunt ratio, after the general use of the operational term coupling ratio.
Conceptually, a proton shunt through the enzyme is just the simplest way to displace ER toward EH; and the quantitative consequence of such a shunt can readily be derived via a simple linear equivalent circuit, as drawn in Fig. 5. There, one limb represents the coupled pathway through the enzyme, with EP and GP designating the EMF and internal conductance of the pump pathway; and the second limb represents the shunt pathway, with ES and GS designating its EMF and intrinsic conductance. From the equivalent circuit, ER is given by
![]() | (4) |
![]() | (5) |
![]() | (6) |
![]() | (7) |
![]() | (8) |
10, from
0.4, when the cytoplasmic solution was 4.4 pH units alkaline to the vacuole, to
4 when the cytoplasmic and vacuolar solutions were at the same pH. The relative conductance of the shunt, GS/GP, varied by the same factor, but reduced by 0.5 (1/N).
|
| DISCUSSION |
|---|
|
|
|---|
With specific respect to V-ATPases, changes in mechanistic stoichiometry can be envisioned, e.g., if the six proton binding sites (one per subunit c of the V0 domain) differ in their pKa. Then, binding sites with a high pKa could be withdrawn from the transport cycle by staying protonated when exposed to an acidic vacuolar lumen, thus reducing the coupling ratio.
Experimental evidence for a possible change in mechanistic stoichiometry has been reported for a closely related F-ATP synthase (Rastogi and Girvin, 1999
). The proteolipid subunit c, bearing the proton binding site, has a different conformation at acidic and basic pH values. At pH
5, the protonated binding site appears to be buried within the rotor, whereas at pH
8, the deprotonated binding site seems to be at the rotor periphery. If the same circumstance holds for V-ATPases, positioning at low vacuolar pH would expose fewer potential H+-transporting sites to surface exchange, so that pump stoichiometry should be low with acidic vacuolar pH and high with alkaline vacuolar pH. This prediction is in rough agreement with our data: at acidic pH (
pH = 4), the coupling ratio is near 2.5, whereas at alkaline pH (
pH = 0), it rises toward 5. But a stoichiometry of N > 2 would require cryptic proton binding sites not explicitly recognized in structural models of the V-ATPase. Even though three distinct c-subunit homologs compose the rotor of yeast V-ATPase, with a stoichiometry of 45:1:1, each subunit bears only a single known H+-binding site.
History has come down in favor of the second viewpoint, in part because of intrinsic difficulties like that just discussed for the V-ATPase, but also in part because the second is less demanding and admits a multitude of details, most of which do not involve energy conservation or optimization of efficiency. (Indeed, most actually involve modulation of energy dissipation, as an integral part of transport regulation.) Thus, slip has become a popular redoubt for variable coupling ratios: the execution of only one of a pair of normally coupled steps, during the full reaction cycle of a transport protein. ATP might be hydrolyzed without the normally coupled flux of protons, the transport enzyme nevertheless returning to its initial state; or protons might leak through the enzyme without the hydrolysis of ATP. This kind of mechanism is at heart probabilistic, with experimental circumstances determining the operant probability for each half reaction or the whole reaction to take place. The idea of slip, or uncoupling, has been applied to variable stoichiometries in a wide range of transporters, including V-ATPases, the Na+,K+-ATPase (Cornelius, 1990
; Goldshleger et al, 1990
), the SR calcium pump (Sumbilla et al., 2002
), the mammalian Na+-glucose co-transporter SGLT (Chen et al., 1995
), Na+-coupled amino acid transport in rabbit intestine (Paterson et al., 1980
), and the yeast cytosine transporter (Eddy et al., 1994
).
Proton shunt for the yeast V-ATPase
Ion shunting, as postulated here for the yeast V-ATPase, can be viewed as a type of slip, but that is not the only possibility. The overall structural similarities between channels and carriers which have emerged over the past 10 years suggest that under sufficient stress, all carrier-type transporters will occasionally open enough to transmit ions in channel fashion. Such behavior would impact both on the measured or deduced coupling ratios and on the electrical parameters of the transport system; and it could well have been used in evolution to modulate transport processes, albeit at the expense of energetic efficiency. Although coupling ratios inferred from thermodynamic measurements alone (Davies et al., 1994
; Yabe et al., 1999
) are, in principle, especially vulnerable to errors from ion shunting, V-ATPase coupling ratios inferred from measurements of ion and substrate flux have also shown similar variability (Moriyama and Nelson, 1988
; Müller et al., 1999
).
An important and frankly paradoxical aspect of the shunt mechanism is that the proton flux that produces apparent variations of coupling ratio always flows downhillwhich is in reverse direction to the usual proton pumping. It is the electrical effect of this proton shunting which produces the calculation of variable coupling, because resultant measurements of ER differ significantly from EP. Again, as ER shifts away from EP toward EH, the calculated coupling ratio n must increase (see Table 2 and the text introducing Eq. 3, in the Introduction).
A second consequence of the shunt mechanism, as manifest with the yeast and plant V-ATPases, is that the shunt diminishes as the imposed driving force increases (Table 2, columns 9 and 10). Operationally, the apparent coupling ratio approaches the ideal stoichiometry of 2 H+:ATP with large proton gradients (vacuole > 4 pH units acid to cytoplasm), and increases as the proton gradient decreases. From an energetic point of view, that is a sensible arrangement, because it embodies negative feedback: reducing the shunt would increase the operating efficiency of ATP-driven forward proton flux (cytoplasm to vacuole), thereby aiding the formation of large gradients.
The conductances GS and GP are both functions of voltage and
pH (or EH) which are not explicitly known. Although both could be derived by modeling pump I-V curves obtained under a range of conditions, it is actually only the ratio, GS/GP, which determines the deviation of ER from EP = EATP/N + EH. In the simplest circumstances, the contribution made by proton leak to variable coupling ratios in the V-ATPase, should be largest when the electrochemical gradientexplicitly, the trans-tonoplast
pH or EHis largest. This would be true if GS were fixed, or, more generally, under thermodynamic control. However, in an important recent mechanochemical model of the V-ATPase (Grabe et al., 2000
), the leak component of slip (see Interpretation of Variable Coupling Ratios: Noncoupled Ion Movements, above) was argued to increase as conditions approach the stalling point for the enzyme: namely, as the imposed membrane voltage (Vm) approaches the reversal voltage for the whole electrochemical reaction, EATP/N + EH. That prediction arose from the idea that Brownian torque (Oster, 2002
) should allow the rotor maximal opportunity to wobble between the input and output proton channels within the stator of the V-ATPase, when the rapid unidirectional rotation normally driven by ATP hydrolysis is not occurring.
If proton shunting through the V-ATPase arises, in the above-discussed fashion, as a Brownian shuttle mechanism, then the per-site leak rates should be compatible with the normal turnover numbers for the enzyme. However, proton shunting could equally arise as transient disruptions of function, allowing individual molecules of the ATPase briefly to behave as bona fide channels. This could be a very rare process, but one which could still have large effects on proton flux, membrane current or voltage (absent the voltage clamp), and computed coupling ratios, because channels usually display much larger unit fluxes than do pumps and co-transporters. Typical carrier turnover numbers are in the range of 101000 ions/s, whereas channel turnovers range between 105 and 109 ions/s. Thus, only a few disrupted ATPase molecules could short-circuit the current pumped by a few hundred thousand fully coupled molecules. Obviously, there is more than ample flexibility in such numbers to modulate the conductance ratio, GS/GP (Table 2), over the observed 10-fold range. Such disrupted behavior could arise either accidentally, for example during normal protein degradation and recycling, or purposefully, as a component of transport regulation. Indeed, in circumstances where energy conservation is not an essential problem, such as in yeast cells fed on excess glucose (as is customary in the laboratory), channel-like shunting of ions through active transporters could be an extremely sensitive mechanism for regulating net transport.
Fortunately, the hypothesis that variable coupling ratios in the plant and yeast V-ATPases arise primarily from proton shunting is open to experimental testing. For example, with large plant-cell vacuoles, such as those from Characean algae, it should be possible to measure net proton fluxes and ATP hydrolysis associated with V-ATPase pumping, at multiple points along the current-voltage curve. And the corresponding pH measurements should also be feasible with normal-sized plant vacuoles or large fungal vacuoles (e.g., from Neurospora), by means of ion-sensitive microelectrodes. Noise measurements on lemon, sugar-beet, or yeast vacuole might also reveal channel-like events blocked by V-ATPase inhibitors, such as bafilomycin. Finally, in a genetically compliant system such as Saccharomyces, introduction of subunit mutationsespecially into the a subunit (stator) and the c subunits (rotor)could have profound and revealing effects upon measurable properties of the enzyme, including the I-V curve, reversal voltage, coupling ratio, noise characteristics, pH-dependence, salt sensitivity, and thermal sensitivity.
| ACKNOWLEDGEMENTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
Submitted on June 23, 2003; accepted for publication August 20, 2003.
| REFERENCES |
|---|
|
|
|---|
Arata, Y., T. Nishi, S. Kawasaki-Nishi, E. Shao, S. Wilkens, and M. Forgac. 2002. Structure, subunit function and regulation of the coated vesicle and yeast vacuolar (H+)-ATPases. Biochim. Biophys. Acta. 1555:7174.[Medline]
Bennett, A. B., and R. M. Spanswick. 1984. H+-ATPase activity from storage tissue of Beta vulgaris II. H+/ATP stoichiometry of an anion-sensitive H+-ATPase. Plant Physiol. 74:545548.
Bertl, A., E. Blumwald, R. Coronado, R. Eisenberg, G. Findlay, D. Gradmann, B. Hille, K. Köhler, H. A. Kolb, E. MacRobbie, G. Meissner, C. Miller, E. Neher, P. Palade, O. Pantoja, D. Sanders, J. Schroeder, C. L. Slayman, R. Spanswick, and A. Williams. 1992. Electrical measurements on endomembranes. Science. 258:873874.
Bertl, A., H. Bihler, C. Kettner, and C. L. Slayman. 1998. Electrophysiology in the eukaryotic model cell Saccharomyces cerevisiae. Pflügers Arch. Eur. J. Physiol. 436:9991013.[Medline]
Bertl, A., and C. L. Slayman. 1990. Cation-selective channels in the vacuolar membrane of Saccharomyces: dependence on calcium, redox state, and voltage. Proc. Natl. Acad. Sci. USA. 87:78247828.
Bertl, A., and C. L. Slayman. 1992. Complex modulation of cation channels in the tonoplast and plasma membrane of Saccharomyces cerevisiae: single-channel studies. J. Exp. Biol. 172:271287.
Chen, X.-Z., M. J. Coady, F. Jackson, A. Berteloot, and J. Y. Lapointe. 1995. Thermodynamic determination of the Na+:glucose coupling ratio for the human SGLT1 co-transporter. Biophys. J. 69:24052414.
Cornelius, F. 1990. Variable stoichiometry in reconstituted shark Na,K-ATPase engaged in uncoupled efflux. Biochim. Biophys. Acta. 1026:147152.[Medline]
Davies, J. M., I. Hunt, and D. Sanders. 1994. Vacuolar H+-pumping ATPase variable transport coupling ratio controlled by pH. Proc. Natl. Acad. Sci. USA. 91:85478551.
Davies, J. M., D. Sanders, and D. Gradmann. 1996. Reaction kinetics of the vacuolar H+-pumping ATPase in Beta vulgaris. J. Membr. Biol. 150:231241.[Medline]
Eddy, A. A., P. Hopkins, and R. Shaw. 1994. Proton and charge circulation through the substrate symports in Saccharomyces cerevisiae: non-classical behaviour of the cytosine symport. Symp. Soc. Exp. Biol. 48:123139.[Medline]
Finbow, M. E., and M. A. Harrison. 1997. The vacuolar H+-ATPase: a universal proton pump of eukaryotes. Biochem. J. 324:697712.[Medline]
Föhr, K. J., W. Warchol, and M. Gratzl. 1993. Calculation and control of free divalent cations in solutions used for membrane fusion studies. Methods Enzymol. 221:149157.[Medline]
Goldshleger, R., Y. Shahak, and S. J. D. Karlish. 1990. Electrogenic and electroneutral transport modes of renal Na/K ATPase reconstituted into proteoliposomes. J. Membr. Biol. 113:139154.[Medline]
Grabe, M., H. Wang, and G. Oster. 2000. The mechanochemistry of V-ATPase proton pumps. Biophys. J. 78:27982813.
Grüber, G., H. Wieczorek, W. R. Harvey, and V. Müller. 2001. Structure-function relationship of A-, F-, and V-ATPases. J. Exp. Biol. 204:25972605.
Hansen, U. P., D. Gradmann, D. Sanders, and C. L. Slayman. 1981. Interpretation of current-voltage relationships for "active" ion transport systems: I. Steady-state reaction-kinetic analysis of class-I mechanisms. J. Membr. Biol. 63:165190.[Medline]
Kettner, C. 1999. Elektrophysiologische Charakterisierung der vakuolären H+-ATPase von Saccharomyces cerevisiae. Shaker Verlag, Aachen, Germany.
Kettner, C., G. Obermeyer, and A. Bertl. 2003. Inhibition of the yeast V-type ATPase by cytosolic ADP. FEBS Lett. 535:119124.[Medline]
Konings, W. N., and I. R. Booth. 1981. Do the stoichiometries of ion-linked transport systems vary? Trends Biochem. Sci. 6:257262.
Mirzayan, C., C. S. Copeland, and M. Snyder. 1992. The NUF1 gene encodes an essential coiled-coiled related protein that is a potential component of the yeast nucleoskeleton. J. Cell Biol. 116:13191332.
Moriyama, Y. N. and Nelson. 1988. The vacuolar H+-ATPase, a proton pump controlled by a slip. In The Ion Pumps: Structure, Function and Regulation. W. D. Stein, editor. Alan R. Liss, Inc., New York. 387393.
Müller, M. L., M. Jensen, and L. Taiz. 1999. The vacuolar H+-ATPase of lemon fruits is regulated by variable H+/ATP coupling and slip. J. Biol. Chem. 274:1070610716.
Müller, M. L., and L. Taiz. 2002. Regulation of the lemon-fruit V-ATPase by variable stoichiometry and organic acids. J. Membr. Biol. 185:209220.[Medline]
Nishi, T., and M. Forgac. 2002. The vacuolar (H+)-ATPasesnature's most versatile proton pumps. Nat. Rev. Mol. Cell Biol. 3:94103.[Medline]
Oster, G. 2002. Darwin's motors. Nature. 417:25.[Medline]
Paterson, J. Y. F., F. V. Sepulveda, and M. W. Smith. 1980. Stoichiometry versus coupling ratio in the cotransport of Na and different neutral amino acids. Biochim. Biophys. Acta. 603:288297.[Medline]
Rastogi, V. K., and M. E. Girvin. 1999. Structural changes linked to proton translocation by subunit c of the ATP synthase. Nature. 402:263268.[Medline]
Schmidt, A. L., and D. P. Briskin. 1993. Energy transduction in tonoplast vesicles from red beet (Beta vulgaris L.) storage tissue: H+ substrate stoichiometries for the H+-ATPase and H+-PPase. Arch. Biochem. Biophys. 301:165173.[Medline]
Sumbilla, C., D. Lewis, T. Hammerschmidt, and G. Inesi. 2002. The slippage of the Ca2+ pump and its control by anions and curcumin in skeletal and cardiac sarcoplasmic reticulum. J. Biol. Chem. 277:1390013906.
Warncke, J., and C. L. Slayman. 1980. Metabolic modulation of stoichiometry in a proton pump. Biochim. Biophys. Acta. 591:224233.[Medline]
Yabe, I., K. Horiuchi, K. Nakahara, T. Hiyama, T. Yamanaka, P. Wang, K. Toda, A. Hirata, Y. Ohsumi, R. Hirata, Y. Anraku, and I. Kusaka. 1999. Patch clamp studies on V-type ATPase of vacuolar membrane of haploid Saccharomyces cerevisiae. J. Biol. Chem. 274:3490334910.
This article has been cited by other articles:
![]() |
G.-F. Zeng, M. Pypaert, and C. L. Slayman Epitope Tagging of the Yeast K+ Carrier Trk2p Demonstrates Folding That Is Consistent with a Channel-like Structure J. Biol. Chem., January 23, 2004; 279(4): 3003 - 3013. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |