Biophysical Journal 86:2566-2582 (2004)
© 2004 The Biophysical Society
Longitudinal Diffusion in Retinal Rod and Cone Outer Segment Cytoplasm: The Consequence of Cell Structure
David Holcman and
Juan I. Korenbrot
Keck Center for Theoretical Neurobiology and Department of Physiology, School of Medicine, University of California at San Francisco, San Francisco, California
Correspondence: Address reprint requests to Juan I. Korenbrot, Dept. of Physiology, School of Medicine, Box 0444, University of California at San Francisco, San Francisco, CA 94143. Tel.: 415-476-1652; Fax: 415-476-4929; E-mail: juan{at}itsa.ucsf.edu.
 |
ABSTRACT
|
|---|
Excitation signals spread along photoreceptor outer segments away from the site of photon capture because of longitudinal diffusion of cGMP, a cytoplasmic second messenger. The quantitative features of longitudinal diffusion reflect the anatomical structure of the outer segment, known to be profoundly different in rod and cone photoreceptors. To explore how structural differences affect cytoplasmic diffusion and to assess whether longitudinal diffusion may contribute to the difference in signal transduction between photoreceptor types, we investigated, both theoretically and experimentally, the longitudinal diffusion of small, hydrophilic molecules in outer segments. We developed a new theoretical analysis to explicitly compute the longitudinal diffusion constant, Dl, in terms of outer segment structure. Using time-resolved fluorescence imaging we measured Dl of Alexa488 and lucifer yellow in intact, single cones and validated the theoretical analysis. We used numerical simulations of the theoretical model to investigate cGMP diffusion in outer segments of various species. At a given time interval, cGMP spreads further in rod than in cone outer segments of the same dimensions. Across all species, the spatial spread of cGMP at the peak of the dim light photocurrent is 35 µm in rod outer segments, regardless of their absolute size. Similarly the cGMP spatial spread is 0.71 µm in cone outer segments, independently of their dimensions.
 |
INTRODUCTION
|
|---|
In retinal rod photoreceptors, transduction and adaptation signals spread along the outer segment (OS) away from the site of photon capture (Hagins et al., 1970
; Lamb et al., 1981
; Hemila and Reuter, 1981
; Matthews, 1986
). Hagins et al. (1970)
first proposed that cytoplasmic longitudinal diffusion of a then-undetermined second messenger could explain this spatial spread. By now, the longitudinal diffusion of the transduction messengers, cGMP (Koutalos et al., 1995a
,b
) and Ca2+ (Gray-Keller et al., 1999
; Nakatani et al., 2002
), as well as that of other small hydrophilic molecules (Hochstrate and Ruppel, 1980
; Olson and Pugh, 1993
) have been measured in rod outer segments (ROS) and have validated the original idea. For any given molecule, cytoplasmic diffusion in ROS is slower than in aqueous solution because of the mechanical hindrance imposed by the stacked disks that fill the outer segment (Olson and Pugh, 1993
). In cone photoreceptors, the quantitative features of the spatial spread of excitation and adaptation are unknown and cytoplasmic longitudinal diffusion has not been previously investigated.
The terms rod and cone were first used to denote gross differences in the cytological appearance of the retinal photoreceptor outer segments. This gross difference, however, is much more prominent in nonmammalian species than in mammals. In all vertebrates, nonetheless, rods and cones differ profoundly in the detailed cytoarchitecture of their respective OS (reviewed in Borwein, 1981
). In both rods and cones, OS formation begins as an evagination of the plasma membrane at the base of the organelle (Steinberg et al., 1980
; Knabe and Kuhn, 1998
). In rods, the evaginations transform into collapsed disks separated from the plasma membrane over the full OS length. The intradisk volume is electrically and osmotically disconnected from the plasma membrane and from other disks (Hagins and Ruppel, 1971
; Korenbrot et al., 1973
). In every species studied in detail, ROS disks are
150 Å thick each and are stacked with almost crystalline precision at 300 Å repeat distance (Rosenkranz, 1970
; Blaurock and Wilkins, 1969
). The peripheral disk edge is
150 Å away from the plasma membrane. Disks are fractured by 150 Å wide incisures that start at the edge and run along the disk radius. The incisures vary in number and length among species. Their number can range from 1 in mice and humans to 18 in tiger salamander (Olson and Pugh, 1993
), and they can be as long as the ROS radius (toad; Roof and Heuser, 1982
) or less than one-half the radius in length (rat; Leeson, 1970
; Pedler and Tilly, 1967
). Disks are structurally linked by an elaborate scaffold of filaments that reach from disk to disk, from disk edge to plasma membrane and from disk edge to disk edge across the incisures (Roof and Heuser, 1982
). This structural scaffolding holds disks in a stable, permanent position and, as a result, incisures in individual disks are aligned with each other, forming crevices that stretch over anywhere from 20 to 60% of the outer segment length (Clark and Branton, 1968
; Korenbrot et al., 1973
).
In cones, the membrane evaginations that form the OS do not close onto themselves and do not form disks separated from the plasma membrane (Nilsson, 1964
, 1965
; Knabe and Kuhn, 1998
). The evaginations fan back and forth to create folds stacked along the cone outer segment (COS) length, ordered with almost crystalline precision (Fetter and Corless, 1987
). The repeat distance between successive folds is
300 Å and each fold is
150 Å thick. The extracellular interfold gap is
150 Å thick and is continuous with the extracellular space (Cohen, 1968
; Laties and Liebman, 1970
). Membrane folds lack radial incisures like those in ROS. The COS membrane folds are not free-floating; they are rigidly maintained in their stable positions by an elaborate scaffold of filaments that reach from the edge of one fold to its immediate neighbors (Fetter and Corless, 1987
). The plasma membrane wraps over one-half of each fold's perimeter and then fuses with the fold at two singular points, each diametrically opposite the other, referred to as saddle points (Fetter and Corless, 1987
). Each cone membrane fold, hence, has approximately one-half its perimeter exposed to extracellular space (open loop) and the other half exposed to the cytoplasmic space (closed loop), separated by a 100 Å gap from the plasma membrane.
Elegant previous studies have shown that longitudinal cytoplasmic diffusion in ROS is well described by the standard solution of the one-dimensional diffusion equation solved for specific boundary conditions (Olson and Pugh, 1993
). For several small molecules, cGMP among them, diffusion along the outer segment has been described using empiric diffusion constants, Dlong, obtained by matching experimental data with numerical solutions (Olson and Pugh, 1993
; Koutalos et al., 1995a
,b
). Dlong has been inferred to reflect mechanical obstruction by rod disks as well as potential binding to cytoplasmic sites (Olson and Pugh, 1993
), different than the usual theory of reaction-diffusion where Dlong reflects only properties of motion, not binding.
Cone photoreceptors respond to light with a change in membrane current that is faster, is less sensitive to light, and which adapts over a far broader range of light intensities than do rod photoreceptors (reviewed in Pugh and Lamb, 2000
). To explore how the distinct cone and rod OS structures affect cytoplasmic longitudinal diffusion and to assess whether longitudinal diffusion may contribute to the difference in signal transduction between photoreceptor types, we investigated, both theoretically and experimentally, cytoplasmic diffusion along the photoreceptor OS length. In the mathematical analysis, Dl, the longitudinal diffusion constant in ROS and COS, is computed explicitly in terms of the cell structure. In cones, unlike rods, diffusion cannot be described by the standard linear one-dimensional diffusion equation, inasmuch as the diffusion coefficient Dl(x) varies with OS length; its value can instead be derived from the known COS structure. We measured the longitudinal cytoplasmic diffusion of small, hydrophilic fluorescent molecules in single COS isolated from striped bass and examined the experimental results with the aid of the mathematical analysis. We use the mathematical analysis to predict the spread of cGMP in cones and rods, which we find to be significantly different even for OS of nearly identical dimensions.
 |
MATERIALS AND METHODS
|
|---|
Materials
Striped bass (Morone saxitilis) were obtained from Professional Aquaculture Services (Chico, CA) and maintained in the laboratory for up to six weeks under 10:14 h dark/light cycles. The University of California, San Francisco Committee on Animal Research approved protocols for the upkeep and sacrifice of the animals. AlexaFluor 488 hydrazide, Na+ salt, and lucifer yellow CH, lithium salt, were purchased from Molecular Probes (Eugene, OR). The aqueous diffusion constant, Daq, at 20°C of Alexa 488 (400 µm2 s-1) were computed from the known Daq of ATP (Bowen and Martin, 1964) and the Einstein-Stokes equation,
. Enzymes for tissue dissociation were obtained from Worthington Biochemical (Lakewood, NJ). All other chemicals were from Sigma Chemicals (St. Louis, MO).
Photoreceptor isolation
Under infrared illumination and with the aid of a TV camera and monitor, retinas were isolated from dark-adapted animals, briefly treated with collagenase and hyaluronidase, and photoreceptors dissociated by mechanical trituration as described in detail elsewhere (Miller and Korenbrot, 1993
). Photoreceptors were dissociated in a Ringer's solution in which glucose was replaced with 5 mM pyruvate. The standard Ringer's composition was (in mM): NaCl (136), KCl (2.4), NaHCO3 (5), NaH2PO4 (1), MgCl2 (1), CaCl2 (1), Minimum Essential Medium amino acids and vitamins (Gibco-BRL), glucose (10), bovine serum albumin (0.1 mg/ml), and HEPES (10). The pH was 7.5 and osmotic pressure was 310 mOsM.
Cells suspended in pyruvate Ringer's solution (
150 µl) were deposited onto a recording chamber held on the stage of an inverted microscope. The floor of the recording chamber was a glass coverslip covalently coated with Concanavalin A (3 mg/ml) (Picones and Korenbrot, 1992
). Solitary photoreceptors were firmly attached to the coverslip and after 10 min the cell-bathing solution was exchanged with normal, glucose-containing Ringer's. The bath solution was intermittently perfused throughout the experimental session.
Membrane currents in intact, single cones
We measured membrane current under voltage-clamp using tight-seal electrodes in the whole-cell mode. Electrodes were produced from aluminosilicate glass (Corning 1724, 1.5 x 1.0 mm od x id). Using differential interference contrast (DIC) optics, a charge-coupled device camera, and monitors, and under orange (>560 nm) illumination, electrodes were sealed onto the side of the inner segment. Currents were recorded with a patch-clamp amplifier (Axopatch 1D; Axon Instruments, Foster City, CA). Analog signals were low-pass-filtered below 100 Hz with an eight-pole Bessel filter (Kronh-Hite, Avon, MA) and digitized online at 200 Hz (Digidata 1200 and pClamp software, Axon Instruments, Union City, CA).
The composition of the tight-seal electrode-filling solution was (in mM): K+ gluconate (115), K+ aspartate (20), KCl (33), BAPTA (1), MgCl2 (1 free), and MOPS (10). The pH was 7.25 and osmotic pressure was 305 mOsM. The solution lacked triphosphate nucleotides and, therefore, could not sustain endogenous synthesis of cGMP and phototransduction (Hestrin and Korenbrot, 1987
; Rispoli et al., 1993
). We included in the solution either of two fluorescent dye molecules (fluorochromes), Alexa488 (0.2 mM) or lucifer yellow (12.5 mM).
Image acquisition and analysis
Simultaneously with membrane current we captured fluorescent images of the single cone being recorded. We used an instrument described in detail elsewhere (Ohyama et al., 2000
) to observe cells with a near-ultraviolet transmitting, high numerical-aperture objective (Fluo 40x/1.3 NA, Nikon Optics, Melville, NY). An epi-illumination pathway was used to bring fluorescence excitation light to the cells and fluorochrome-specific epicubes were used to spectrally separate fluorescence excitation from emission light. This epi-illumination pathway used a DC-operated Xe light source and included an electromechanical shutter and a pinhole aperture. The aperture restricted fluorescence excitation to a 45-µM-diameter circle centered on the cell under investigation and the shutter was controlled to limit epifluorescent illumination only to those times images were being acquired. Excitation light intensity at the plane occupied by cells on the microscope stage was relatively dim (460500 nm, 4 x 10-3 Cd m-2) to minimize dye photobleaching. We acquired high-resolution images with a cooled, high-resolution interline charge-coupled device camera (MicroMAX, Princeton Instruments, Trenton, NJ; 5 MHz, 1300(H) x 1030(V) pixels, 6.7 µm x 6.7 µm pixels center to center) operated with appropriate controller and image acquisition boards and software (WinView3.2, Roper Scientific, Trenton, NJ). The optical system could be readily switched to operate either under DIC illumination (for electrophysiological recordings) or epifluorescence.
In general, a cell was selected for investigation and its image first captured under DIC optics. Under video observation a tight-seal electrode was applied onto the surface of the inner segment and a gigaseal formed. Epifluorescent illumination was then engaged and successive single images captured, each integrated over 0.51.5 s, depending on the fluorochrome and its concentration. Integrated single images were acquired every 3 or 5 s, again depending on the fluorochrome and its concentration.
We only analyzed fluorescent images of healthy cells in which the electrode seal remained intact. In successful experiments, current and images were simultaneously collected for 315 min. Using commercially available image analysis software (C. Imaging, Compix, Cranberry Township, PA), each cell's DIC image was first measured to determine cellular dimensions and to design a fluorescence-sampling grid. The grid consisted (depending on cell dimensions) of between 49 and 63 rectangular elements; each element was 0.250.31 µm along the OS length and their transverse dimension was equal to the diameter of the outer segment's base. Each rectangular element was oriented with its transverse (long) dimension perpendicular to the outer segment's longitudinal axis and placed, without a gap, adjacent to its neighboring element. The full set of individual elements covered the entire COS length. Each cell was analyzed with a unique sampling grid designed following the rules stated above, but every single image of a given cell was analyzed with the same grid. Fluorescent intensity was measured at 10-bit resolution as the mean gray level of each element in the sampling grid. Image acquisition was begun before whole-cell mode was attained, thus we always measured the background gray level in the unloaded outer segment. This background fluorescence is shown as a continuous line in the experimental data presented in this report.
 |
A THEORY OF LONGITUDINAL DIFFUSION
|
|---|
General description
In this section we present a mathematical analysis of cytoplasmic longitudinal diffusion in COS and ROS. In this analysis, one-dimensional diffusion equations are derived from first principles and diffusion coefficients are explicitly computed in terms of ROS and COS cytoarchitecture. The method is sufficiently general to be applicable to any cell of known geometry. The principle of the analysis is to reduce the three-dimensional diffusion equation into a one-dimensional equation by averaging over the other two dimensions through detailed consideration of the geometrical organization of the cell. For ROS and COS, the longitudinal diffusion equation is defined as the geometrical reduction of the diffusion equation when the averaging directions are orthogonal to the long axis of the OS. We refer to this process as a geometrical reduction of the three-dimensional diffusion equation.
The derived diffusion equations compute the change in the average concentration along the OS. By definition, the concentration is the number of free particles per volume confined to move in the OS cytoplasm and restricted by disks (in rods) or foldings (in cones) that are impenetrable barriers. The following analysis reveals that because of translational invariance, the longitudinal diffusion equation in rods is the standard diffusion equation with constant longitudinal diffusion coefficient. In COS, in contrast, the diffusion coefficient is not a constant value, but changes with longitudinal position.
Aqueous diffusion in the outer segment cytoplasm, model, and simplifications
Brownian particles in the OS are driven by thermal noise and their trajectory in the cytoplasm is well described by the overdamped approximation (Smoluchowski limit) of the Langevin equation. Thus, for a molecule located at position x(t), in the limit of large viscosity coefficient, the velocity satisfies the stochastic equation
 | (1) |
where F(x) are forces applied onto the particle,
is the viscosity coefficient,
is the thermal noise, and
is the white noise produced by thermal collisions (Schuss, 1980
).
To study Eq. 1, we make three assumptions:
- Particles do not bind.
- In the timescale of seconds, short-range electrostatic interactions that arise from the charged disk membrane surfaces (McLaughlin and Brown, 1981
) and/or charged particles in solution average and cancel out. As a consequence all electrostatic terms are neglected and the force term F(x) in Eq. 1 is set to 0.
- Particles do not permeate across OS membranes.
From the general theory of diffusion, it is well known that the probability density function (pdf) of one molecule associated with Eq. 1 satisfies the standard three-dimensional diffusion equation in the cytoplasm. Under the assumption of independent molecules, the concentration is simply the product of the pdf by the number of molecules and satisfies the following diffusion equation within the OS,
 | (2) |
 | (3) |
where c0(x) is some initial concentration, and D is the diffusion constant given by Schuss (1980)
, as
 | (4) |
where m is the mass of the molecule,
the viscosity coefficient, T the absolute temperature, and k the Boltzmann constant.
Longitudinal diffusion in rod outer segments
Definition of a rod compartment
ROS consists of repeating spatial compartments, Uk (Fig. 1). Each compartment comprises the distance from one disk surface to the comparable surface in the next disk. The repeat distance is l, and it consists of two equal parts: the cytoplasmic space separating two adjacent disks (interdisk space, dimension = l/2) and the disk itself (dimension = l/2).
Diffusion between adjacent interdisk spaces occurs either through disk incisures or the perimetric gap that separates disk edges from the plasma membrane. The compartment's radius is constant and denoted by r. We adopt the following notation: Nk is the number of free Brownian particles in the Uk compartment of volume Vk.
Derivation of the diffusion equation
The objective of the following derivation is to compute the ROS longitudinal diffusion constant, Dl, in terms of the cell's structure. Variation in the number of particles in unit Uk equals the difference of flux into compartments k-1 and k+1; that is,
 | (5) |
By definition, Jk+1 is the flux between unit Uk and Uk+1 through
k+1, the open surface that joins them, as
 | (6) |
where n(x) is the normal derivative pointing outside Uk and
.
In the timescale of seconds, concentration is assumed to be uniform within each Uk compartment. This assumption is valid because diffusion along the longitudinal axis is much slower than along the transverse axis (Olson and Pugh, 1993
). This fact follows from:
- Diffusion within a compartment (transverse diffusion) is given by the standard two-dimensional diffusion process and is limited only by aqueous diffusion and not by anatomical constraints (Schuss, 1980
).
- The ratio of the absorbing boundary surface divided by the reflective boundary surface of a given compartment is small.
Combining Eqs. 5 and 6 yields
 | (7) |
where
incs is the surface area of a single disk incisure, n is the number of incisures, and
g is the surface of the perimeter gap between the disk's edge and plasma membrane; and
, where r is the ROS radius and gw is the size of the perimeter gap.
The concentration at points
and xk is evaluated by a Taylor expansion. At the first order, inasmuch as
, then
 | (8) |
The translation invariance of the rod outer-segment geometry implies that the volume Vk of the compartment Uk is constant with respect to k and equals the free intracellular volume (free volume of the unit plus the free volume of the incisures), as
 | (9) |
where Vincs is the volume of the incisure and Vg is the volume of the perimeter gap. Finally, Eq. 8 can be reduced to the form of the standard one-dimensional diffusion equation,
 | (10) |
where the longitudinal diffusion constant is defined to be
 | (11) |
Longitudinal diffusion in cone outer segments
Definition of cone compartment
COS consists of repeating Uk compartments, each comprising the distance from the intracellular surface of one membrane fold to the intracellular surface of the next one (Fig. 1). The repeat distance is l and it consists of two segments: the membrane fold (dimension = l/2) and the distance separating one fold from the next (dimension = l/2). In reality, the surface connecting adjacent folds is the hemitorus between the fold's closed loop and the plasma membrane (Fig. 1) (Fetter and Corless, 1987
). We assume that, on average, the geometry of this surface does not change with COS length and is well approximated by a cylinder of length = l/2 and diameter
. That is,
is the diameter of a circle of area equal to the area of the toroidal surface. We refer to
as the equivalent diameter. The diameter of a membrane fold at position xk is denoted by dk. dk increases linearly with the longitudinal coordinate as given by dk+1 = dk + d0, where d0 is the unitary increment in diameter between immediately adjacent folds.
Derivation of the diffusion equation
Derivation of the longitudinal diffusion equation in COS proceeds through the same steps as the derivation for ROS, but the end result differs because the spatial compartments, Uk, change with COS length. As in ROS, the time variation in the particle number in the Uk compartment is given by Eq. 5 and the flux through the
k+1 surface is given by Eq. 6. From these equations, the variation in time of the concentration in a COS compartment is given by
 | (12) |
Inasmuch as
k+1 =
k, using a Taylor expansion of the concentration c(x,t), we have
 | (13) |
The area of the surface
k+1 is given by
k+1 =
(
/2)2 and its volume is
 | (14) |
We define dmin as the smallest COS diameter (at the tip), dmax as the largest diameter (at the base), and L as the COS length. Furthermore,
 | (15) |
Because of the cone geometry, at position xk the cone diameter is dk =
xk + dmin, and the longitudinal diffusion equation can now be expressed as
 | (16) |
but for x
[0,L], the equation simplifies to
 | (17) |
The longitudinal diffusion coefficient (which is now, in one dimension, a function of x) is explicitly given by
 | (18) |
Determination of the anatom ical diameter function
a(x) from the COS structure
Given the COS structure, Eq. 17 can be modified to include a spatial dependency on the
-variable. Recall that the COS geometry is characterized by the following global parameters. L is the length, rbase is the radius at the base, rtip is the radius at the tip, and
The hemitoroidal surface connecting adjacent folds at the longitudinal position x is
g(x). If rm(x) is the radius up to the plasma membrane and rf(x) is the radius of the membrane fold at position x, then the area of
g(x) is (see Fig. 1)
 | (19) |
for
 | (20) |
 | (21) |
The gap
r between the closed loop of a fold and the plasma membrane is
100 Å; that is,
r = rm - rf = 0.01 µm is small compared to rm. For that reason, we can approximate
g(x) as
 | (22) |
Let us define the anatomical diameter function
a(x) as the diameter of a circle whose area is identical to that of
g(x) . Thus,
 | (23) |
and
 | (24) |
We can now define the average surface,
, along the COS by
 | (25) |
The average diameter,
, is
 | (26) |
Cone diffusion longitudinal equation
Using the result of the previous section, the function
(x) can be incorporated into the cone diffusion equation and Eq. 16 becomes
 | (27) |
with
 | (28) |
The diffusion coefficient is now given by
 | (29) |
and the cone diffusion equation becomes
 | (30) |
Spread space constant in a rod outer segment,
rod
To evaluate the longitudinal spread of any molecule, space constants for COS and ROS are defined using the equations derived above. The result of this section is used to compare the spread of excitation in rods versus cones.
Since the diffusion equation in ROS is linear, the second moment of the probability density function of the diffusion process p, conditioned by the initial location of the source at position x0, defines, at each moment in time, a spread length constant
rod(t). In an ROS of length L, the second moment is defined by
 | (31) |
The spread space constant
rod for rods is defined as the value of
rod(t) for t = tp, where tp is the time to peak of a photoresponse. The value tp is a fundamental characteristic of the response time of a rod to a single photon,
 | (32) |
when L is large, and
rod is independent of the initial position x0 and is well approximated by the standard deviation of a free diffusion process. Thus,
 | (33) |
Spread space function in a cone outer segment,
cone(x)
As described above, longitudinal diffusion in COS differs from that in ROS in two major respects:
- The diffusion equation in COS is not symmetric with respect to its initial position and this lack of symmetry implies that the first moment or the mean displacement is not 0.
- An exact solution of the cone longitudinal diffusion equation is not known; therefore, it cannot be used to estimate the moments of the pdf. In the Appendix, however, we present an exact solution valid under restricted conditions.
To compare diffusion in ROS and COS, nonetheless, an approximation can be used to define a spread space function in cones
cone(x) at the time of the photocurrent peak, comparable to that defined above for rods. We define a spread function, rather than a spread constant because, recall, diffusion in COS varies with their length. To compute explicitly the spread function
cone(x0), we make the approximation that Dl(x) = Dl(x0)that is, Dl(x) is constant and equal to its value at the initial position x0. This approximation is justified because the time to peak tp in cones is much briefer than in rods and, hence, the spatial spread in COS is much less extensive than in rods, as we demonstrate below (under Discussion). Under the stated approximations, the first moment of the approximated pdf vanishes and the spread function
cone(x0) is defined as in rods,
 | (34) |
where p is the solution of the cone longitudinal equation. The explicit expression for
cone(x0) is given by
 | (35) |
Note that in Eq. 35, the dependency on x0 cannot be ignored because Dl varies in value along the COS. The spread function
cone(x0) keeps track of the location of the initially depleted compartment. This is a significant difference compared to the single spread constant obtained for rods. Equation 35 ignores the asymmetrical profile of the diffusion in COS.
Matching computational simulations and experimental data in bass single COS
Inasmuch as Eq. 17 describes the evolution of the longitudinal concentration c in a COS, to analyze the experimental data the boundary conditions have to be specified. At the COS tip, the origin of the coordinate is (x = 0). Since the particles cannot escape (no leak) and are reflected, the flux to vanish is imposed. That is,
 | (36) |
At the base of the COS, we impose a Dirichlet boundary condition, to match the concentration imposed by the experiment. The concentration equals the time-dependent concentration CL(t) of the diffusing dyes at the COS base (where x = L),
 | (37) |
Since fluorescence intensity is proportional to particle number, not their concentration, the concentration c(x,t) is converted into particle number N(x,t) located in the compartment U(x) by simply writing
 | (38) |
where
is the infinitesimal volume of a compartment, located at position x. The total number of particles in the OS at time t is
 | (39) |
Spatial specifications
The function
(x) reflects the change of the geometry of the COS as a function of x. For the geometry of a generic cone of base radius rbase, tip radius rtip, and length L,
 | (40) |
where
 | (41) |
Specific features of COS in striped bass single cones
In single bass cones, the OS tapers smoothly from their base to a point Lh approximately midway up the length. At that point, which we name the taper transition point, there occurs a small change in the slope of the COS walls which then proceed smoothly to a truncated tip (see Figs. 2 and 3). Thus, for bass cones, the density function is
 | (42) |
 | (43) |
where rh is the radius at location Lh and
 | (44) |
To match the mathematical model with the experimental data in cones, we used Eq. 17 where
, the equivalent diameter, is unknown, but all other parameters are known for each cell investigated: dmin, rtip, tip diameter and radius; dmax, rbase, base diameter and radius; and L, length and Lh, taper transition point. To determine the value of
, we fit experimental data with the results of simulations computed with varying values of
. The cone geometry imposes that the steady-state solution (number of particles) is proportional to the surface of the membrane fold. Thus,
 | (45) |
where
is the number of particles at location rh.

View larger version (48K):
[in this window]
[in a new window]
|
FIGURE 2 Filling of a single bass cone by diffusion of Alexa488 from a tight-seal electrode. The far-left image was captured under DIC illumination and shows the cell with the electrode sealed onto its inner segment. Fluorescent images shown were selected from a collection obtained by repeated 0.5-s epi-illumination flashes (presented once every 3 s, at the marks labeled as light). We designate as 0 the time whole-cell mode (WCM) is first achieved. The arrowed line links fluorescent images with the illumination flashes used to generate that image. Cytoplasmic fluorescence intensity increased progressively, first in the inner segment and then in the outer segment. Also shown is the membrane current measured as the images were being captured. At -40 mV holding voltage, the current was inward immediately upon achieving WCM, but slowly changed to a stationary outward value. Initially, the photoreceptor responded to the test light flashes with the expected cessation of inward current. The photocurrent, however, progressively diminished in amplitude in parallel with the change in holding current and ceased when the holding current reached its steady-state, outward value. The changes in electrical behavior and fluorescence reflect the exchange of contents between the cell and the electrode lumen: the cell is filled with Alexa488 and is depleted of its endogenous cGMP.
|
|

View larger version (62K):
[in this window]
[in a new window]
|
FIGURE 3 Time course of single COS filling with Alexa488. The far left is a DIC image of the COS of the intact single cone analyzed in this figure. COS dimensions were length = 13.48 µm, base diameter = 6.68 µm, and tip diameter = 2.78 µm. One-hundred fluorescent images were acquired at 3-s intervals, each generated by a 0.5-s epi-illumination flash. Shown are selected images each acquired at various times after achieving WCM, as labeled. Fluorescence intensity was measured using a sampling grid consisting of 63 elements placed adjacent to each other over the entire COS length (see Materials and Methods). Each element was 6.7 µm in the transverse axis by 0.21 µm in the longitudinal one, and laid perpendicular to the COS longitudinal axis. The time course of change in fluorescence intensity at selected positions along the COS length is shown in the graph. Before achieving WCM (designated as t = 0) COS fluorescence intensity was the same as background; after WCM, fluorescence intensity increased steadily, first at the COS base and eventually at its tip, revealing the longitudinal flux of Alexa488.
|
|
 |
EXPERIMENTAL RESULTS
|
|---|
We measured cytoplasmic longitudinal diffusion rates of Alexa488 (mw = 570, Daq = 400 µm2/s) and lucifer yellow (mw = 457, Daq = 430 µm2/s) in the outer segment of intact single cones isolated from striped bass. In voltage-clamped cones, we measured membrane current at -40-mV holding voltage and simultaneously acquired the cell's fluorescent image. Images and currents measured with a tight-seal electrode filled with 0.2 mM Alexa488 are shown in Fig. 2. These data are typical of every cell studied. After membrane rupture the current was initially inward, and then smoothly changed over the next minute or so until it reached a stationary outward value. For 12 cones, the mean steady-state outward current was 17.7 ± 7.2 pA. Throughout the current measurement we presented, once every 3 s, a 0.5-s light flashed to generate the fluorescent images. At first, the flashes caused a cessation of the inward current; this photocurrent, however, was progressively smaller in amplitude and irreversibly disappeared
1 min after achieving whole-cell mode (WCM). Both changes in holding current and loss of photoresponse arise from the exchange/replacement of the cell's cytoplasmic content by the electrode-filling solution. Because this solution lacked triphosphate nucleotides the photoreceptor could not synthesize cGMP and, hence, cGMP-gated ion channels in the outer segments closed as the nucleotide was lost by diffusion. In the steady state, phototransduction ceased and net membrane current revealed outward flux through voltage-gated K+ channels located in the cone inner segment membrane (Barnes and Hille, 1989
; Maricq and Korenbrot, 1990
). This electrical behavior is characteristic of healthy, uncompromised cones.
In Fig. 2, an arrowed line links each fluorescent image to the test flash that generated it. At the far left is a DIC image of the same cell captured immediately before the test flash sequence began. Preceding rupture of the membrane seal, fluorescence was only detected within the electrode. Upon attaining whole-cell mode the inner segment cytoplasm immediately began to fill with the dye. After a short delay, Alexa began to flow into the outer segment, across the connecting cilium. At the same time, the dye began to fill the accessory outer segmentan appendage characteristic of fish cones that connects directly to the inner segment (Januschka et al., 1987
). The change in fluorescence reveals the flow of Alexa488 from the pipette lumen into the cell's cytoplasm driven by its concentration gradient and limited by the fluorophore's diffusion rate within the cell.
Longitudinal diffusion of Alexa488 in single cone outer segments
To characterize Alexa488 diffusional flow along the COS length, we measured fluorescence intensity using sampling grids consisting of multiple rectangular elements, each as wide as the COS base, positioned side by side along the OS length (details under Materials and Methods). The dimension of the individual elements in the sampling grid along the COS length defined the spatial resolution in our measurements (mean = 0.30 ± 0.05 µm, n = 13). Fig. 3 illustrates the rate of change in the fluorescence intensity measured at fixed positions along the length of the COS shown, with its base defined as the origin. Results shown are typical of every cell we analyzed (n = 6). The COS fluorescence intensity initially did not differ from that of the background (which arises from the optical crosstalk between fluorescence excitation and emission filters in the microscope). After attaining WCM, however, specific COS fluorescence intensity increased steadily over the course of tens of seconds. Since dye flows into the outer segment through the cilium connecting inner and outer segments, it was not surprising to observe that fluorescence increased at the base of the COS ahead of the rise at its tip.
We used the theoretical analysis detailed above to analyze the COS spatial fluorescent pattern in the course of Alexa488 filling. The mathematical analysis details the spatial distribution of Alexa488 concentration along the COS length at any time between the start of diffusion and the steady-state filling (saturation) of the cell. In Fig. 4 we present the spatial pattern of fluorescence intensity measured in three different COS loaded with 0.2 mM Alexa488 (symbols). For analytical reasons, in these graphs we designated the COS tip as the origin of the spatial variable. For each cell, we show the spatial pattern at various times after achieving WCM, a moment we define as time 0.

View larger version (34K):
[in this window]
[in a new window]
|
FIGURE 4 Spatial pattern of fluorescence intensity at various times after the start of Alexa488 diffusion into single bass COS. Data measured in three different cells are shown. (A) The COS dimensions were length = 13.48 µm, base diameter = 6.68 µm, and tip diameter = 2.78 µm. Fluorescence was sampled with a grid consisting of 63 elements, each 6.7 µm in the transverse axis by 0.21 µm in the longitudinal one. (B) The COS dimensions were length = 13.52 µm, base diameter = 6.29 µm, and tip diameter = 2.59 µm. Fluorescence was sampled with a grid consisting of 51 elements, each 6.9 µm in the transverse axis by 0.32 µm in the longitudinal one. (C) The COS dimensions were length = 16.57 µm, base diameter = 6.87 µm, and tip diameter = 3.11 µm. Fluorescence was sampled with a grid consisting of 61 elements, each 6.9 µm in the transverse axis by 0.27 µm in the longitudinal one. The continuous curves are solutions of the geometrical reduction of the diffusion equation we have derived (see A Theory of Longitudinal Diffusion). The lines describe Alexa concentration as a function of cell longitudinal position, each at a fixed time (as labeled), where t = 0 is the moment WCM is achieved and diffusion begins. Values of the adjustable parameters that generated the curves: (A) = 0.316 µm (the equivalent diameter of the circular surface that joins adjacent COS folds) and Lh = 7.0 µm (the location of the taper transition point); (B) = 0.346 µm and Lh = 6.49 µm; and (C) = 0.316 µm and Lh = 8.62 µm.
|
|
Through computation we generated solutions to the geometrically reduced diffusion equation for a COS. The analytical model defines diffusion to occur from fold to fold across an equivalent circular surface of diameter
. We matched by eye the experimental and computed fluorescence spatial pattern by adjusting the value of
. The values of all other independent variables are known from direct anatomical measurements of the COS. In Fig. 4 we present as continuous curves the computed fluorescence spatial pattern expected at various times after diffusion into the COS starts (as labeled). For each cell analyzed (Fig. 4, AC), we selected a single value of
that yielded the best match between computed and observed patterns of fluorescence for all times. We obtained reasonably good matches between data and simulations, and the results shown in Fig. 4 depict the range of the quality of the matches. Our results indicate that the mathematical analysis describes well the diffusion of Alexa488 in the COS, which arises from Brownian motion restricted only by the cell cytoarchitecture.
In Table 1 we present the collected results of the analysis of Alexa488 diffusion in six different COS. A salient feature inferred from our analysis and data is that the diffusion coefficient in COS is not constant, but changes with longitudinal position as given by Eq. 17. We illustrate this feature in Table 1 by presenting the computed values of Dl at the base and tip of the COS. For all cells, the mean ratio of the diffusion constant at the base over that at the tip was 6.5 ± 0.7.
Longitudinal diffusion of lucifer yellow single cone outer segments
Analysis of cytoplasmic diffusion can be confounded if the sampling probe binds to intracellular sites (Olson and Pugh, 1993
; Koutalos et al., 1995a
,b
). As an experimental control for the adequacy of Alexa488 as a nonbinding probe we characterized the diffusion in COS of a second fluorescent molecule, lucifer yellow (LY). LY (
= 11,000) fluoresces less intensely than Alexa488 (
= 71,000). Therefore, to obtain LY fluorescence intensity data with signal/noise characteristics comparable to the Alexa488 data, we loaded cells with 12.5 mM dye and integrated fluorescence image acquisition for 1.42 s. If binding does not occur, diffusion of LY and Alexa488 should be determined by cytoarchitecture alone.
We measured voltage-clamped current and fluorescence images of single cones while loading their cytoplasm with LY. Healthy cones exhibited electrical behavior similar to that illustrated in Fig. 1 and diffusion was only analyzed in these cells. For LY-loaded photoreceptors mean steady-state outward current was 10.7 ± 6.6 pA (n = 13). We repeatedly acquired fluorescence images at 5-s intervals and, afterwards, measured their fluorescence intensity with spatial grids similar to those used with Alexa488 with nearly identical spatial resolution (mean = 0.30 ± 0.06 µm, n = 9). In Fig. 5 we illustrate the rate of change in fluorescence intensity at fixed positions along a COS loaded with LY. After attaining WCM, fluorescence intensity increased steadily over the course of tens of seconds, starting at the COS base. This temporal pattern, observed in every cell analyzed (n = 6), demonstrates the diffusional flow of LY from the inner to the outer segment through the connecting cilium. The COS filled with LY more rapidly than with Alexa488 (compare Figs. 2 and 5). This finding, of course, simply reflects the fact that the aqueous diffusion constant of LY is larger than Alexa488 because of their size difference.

View larger version (16K):
[in this window]
[in a new window]
|
FIGURE 5 Time course of single COS filling with lucifer yellow. COS dimensions were length = 16.39 µm, base diameter = 6.74 µm, and tip diameter = 2.62 µm. Fluorescence intensity was measured using a sampling grid consisting of 61 elements placed adjacent to each other over the entire COS length (see Materials and Methods). Each element was 7.03 µm in the transverse axis by 0.27 µm in the longitudinal one, and laid perpendicular to the COS longitudinal axis. Before achieving WCM (designated as t = 0) COS fluorescence intensity was the same as background; after WCM, fluorescence intensity increased steadily, first at the COS base and eventually at its tip, revealing the longitudinal flux of lucifer yellow.
|
|
The spatial patterns of fluorescence intensity measured in three different COS loaded with LY are illustrated in Fig. 6 (symbols). For each cell, we show spatial patterns measured at various times after achieving WCM, a moment we define as time 0. To match experimental and computational results, the COS tip is assigned as the origin of the spatial variable. In Fig. 6 we show as continuous curves computed fluorescence spatial patterns that best matched our experimental data. In Fig. 6, AC, the curves are solutions of the reduced diffusion equation for a fixed value of
selected to best fit the experimental results. We obtained reasonably good matches between experimental and computational data, and the results in Fig. 6 illustrate the range of the quality of the fits.

View larger version (28K):
[in this window]
[in a new window]
|
FIGURE 6 Spatial pattern of fluorescence intensity at various times after the start of LY diffusion into single bass COS. Data measured in three different cells are shown. (A) The COS dimensions were length = 14.64 µm, base diameter = 6.32 µm, and tip diameter = 2.10 µm. Fluorescence was sampled with a grid consisting of 51 elements, each 6.4 µm in the transverse axis by 0.29 µm in the longitudinal one. (B) The COS dimensions were length = 15.1 µm, base diameter = 5.52 µm, and tip diameter = 2.06 µm. Fluorescence was sampled with a grid consisting of 51 elements, each 5.5 µm in the transverse axis by 0.30 µm in the longitudinal one. (C) The COS dimensions were length = 17.37 µm, base diameter = 6.88 µm, and tip diameter = 2.26 µm. Fluorescence was sampled with a grid consisting of 68 elements, each 6.9 µm in the transverse axis by 0.26 µm in the longitudinal one. The continuous curves are solutions of the geometrical reduction of the diffusion equation we have derived (see A Theory of Longitudinal Diffusion). The lines describe Alexa concentration as a function of cell longitudinal position, each at a fixed time (as labeled), where t = 0 is the moment WCM is achieved and diffusion begins. Values of the adjustable parameters that generated the curves: (A) = 0.316 µm (the equivalent radius of the circular surface that joins adjacent COS folds) and Lh = 7.32 µm (the location of the taper transition point); (B) = 0.340 µm and Lh = 7.24 µm; and (C) = 0.330 µm and Lh = 8.69 µm.
|
|
In Table 2 we detail the features of LY diffusion in six different cone outer segments. The analysis points out that the value of the longitudinal diffusion coefficient varies with position along the COS length. This feature is highlighted by presenting the value of the diffusion coefficient at the COS base and tip. Despite the difference in the value of diffusion coefficients, LY diffusion yields a value for the equivalent diameter
that is essentially the same as that derived from Alexa488 diffusion (Tables 1 and 2). This verifies that neither fluorophore binds to intracellular sites and their diffusional motion reflects the same mechanical hindrance, imposed by the COS structure.
Anatomical determination of the equivalent diameter 
For both Alexa488 and LY, diffusional flux between adjacent COS folds is well described as occurring across the surface of an equivalent circle, whose diameter
can be known from the fit between experimental and computational data. In our results, the mean
was 0.325 ± 0.012 µm for Alexa488 and 0.324 ± 0.025 µm for LY (Tables 1 and 2). In reality, the surface connecting adjacent folds is not circular; rather, it is a semicircular torus that surrounds one-half the perimeter of the membrane folds over the entire COS length (Fig. 1) (Fetter and Corless, 1987
). If longitudinal diffusion is indeed determined by the COS architecture, then the computed equivalent surface should be the same as the true anatomical surface area.
The anatomical surface area of diffusion can be computed as described in A Theory of Longitudinal Diffusion to yield an anatomical average diameter
. Tables 1 and 2 present the computed
and
-values for both Alexa488 and LY in every cell analyzed. The two numbers are remarkably similar. The small,
10%, but consistent difference between them can be resolved by simply assigning the fraction of the fold's perimeter surrounded by plasma membrane to be 0.4, rather than the stipulated 0.5. Anatomical studies have only approximated the extent of surface draping, and precise morphometric data to resolve the issue do not exist. The similarity in the values of
and
confirms the validity of the diffusion analysis and offers a specific structural insight to the value of
. The quantitative similarity of results arrived at through independent investigation of both Alexa488 and LY affirms the assumption that these fluorescent molecules do not bind in the COS cytoplasm; their molecular movement can be fully described as Brownian motion restricted only by the photoreceptor's cellular architecture.
 |
DISCUSSION
|
|---|
We have developed a theoretical analysis to compute the cytoplasmic longitudinal diffusion constant, Dl in rod and Dl(x) cone outer segments. The value of the diffusion constant depends only on the aqueous diffusion constant of the molecule and the details of the outer segment's structure. The analysis envisions that molecules diffuse between adjacent rod disks or cone membrane folds through a surface defined as an equivalent circle of diameter
. The value of this diameter can be computed from experimental measurements of longitudinal diffusion or from known anatomical OS features, yielding an anatomical equivalent diameter
a. We measured the longitudinal diffusion of Alexa488 and LY in single bass COS and analyzed the experimental data with our method of theoretical analysis. The mean value of
and
a in the bass cone is the same,
0.325 µm (Tables 1 and 2), and measurements with either Alex488 or LY yield the same result. These findings verify that the method of analysis is robust and can be used to study the longitudinal diffusion of hydrophilic molecules of interest, provided they do not bind and are small enough to diffuse within the outer segment.
The analytical method also applies to ROS, where it envisions that molecules diffuse between adjacent interdisk spaces through disk incisures and the gap that separates disks from the plasma membrane. The validity of the analysis to study longitudinal diffusion in ROS is confirmed by the fact that the theoretically computed value of Dl for cGMP in tiger salamander rods overlaps experimentally determined ones (Table 3). Moreover, the Dl value for Alexa488 theoretically computed for tiger salamander ROS (14.5 µm2 s-1) is similar to that determined experimentally (16 µm2 s-1) by measuring the spatial pattern of fluorescence in isolated rods loaded with the dye using the same method described here for cones (our unpublished results).
View this table:
[in this window]
[in a new window]
|
TABLE 3 Comparison of predicted and experimental values of cGMP longitudinal diffusion constant in rod outer segments
|
|
Longitudinal diffusion of cGMP in rod and cone outer segments of similar dimensions
cGMP longitudinal diffusion determines the quantitative features of the spread of photoexcitation over the outer segment length away from the site of photon capture. Spread of photoexcitation in ROS has been measured experimentally in a number of reports (Hagins et al., 1970
; Hemila and Reuter, 1981
; Lamb et al., 1981
; Matthews, 1986
; Gray-Keller et al., 1999
). Results indicate that, at the peak of the photocurrent, signals spread to 1/e of its peak amplitude over distances of between 5 and 15 µm. These values are, at best, upper bounds on the true range of the signal spread because, as discussed in the reports, light scattering makes it impossible to restrict excitation to only a single disk (Hagins et al., 1970
; Hemila and Reuter, 1981
; Lamb et al., 1981
; Matthews, 1986
). The elegant use of two-photon excitation by Gray-Keller et al. (1999)
has reduced this experimental uncertainty and they report that in Gecko ROS and at the peak of the photocurrent (
1 s after a flash), cGMP concentration declines to 1/e of its maximum value over
3.5 µm. Experimental assessment of spatial spread of cGMP in cones has not been reported.
We applied the theoretical analysis to investigate longitudinal diffusion of cGMP in ROS and COS. In our simulations, we assume cGMP movement is only restricted by cytoarchitecture and not by binding. Although the nucleotide binds to noncatalytic sites in the photoreceptor's phosphodiesterase (PDE) (Mou et al., 1999
), their affinity is so high (nM) that the sites are saturated at the µM concentrations expected in dark-adapted photoreceptors. Also, cGMP-gated ion channels bind cGMP, but the concentration of channels at the sites of diffusion is negligible. The dominant effect of binding to channels or PDE is reflected in the transverse diffusion. We present in Tables 3 and 4 computed Dl values of cGMP in ROS and COS (at midlength) of several species in which outer segment structure is known in detail.
View this table:
[in this window]
[in a new window]
|
TABLE 4 Computational predictions of the cGMP longitudinal diffusion constant and characteristic spread space constant in cone outer segments
|
|
To evaluate the spread of cGMP over the length of ROS and COS, its concentration was simulated by imposing an absorbing boundary condition at a given location. This absorbing boundary condition reproduces the instantaneous depletion of cGMP concentration within an active compartment, as would be caused by light-dependent activation of phosphodiesterase. After hydrolysis begins, and in the absence of metabolic replenishment, cGMP concentration decreases throughout the OS as the nucleotide diffuses into the active compartment and is instantly hydrolyzed. The cytoplasmic cGMP concentration is the solution of the PDE,
 | (46) |
under the initial conditions of
 | (47) |
 | (48) |
Since the cGMP cannot escape from the OS, the boundary conditions are
 | (49) |
where L is the total OS length, C0 is the steady-state cGMP concentration, and the depleted compartment is [a1,b1].
In Fig. 7 we illustrate the simulated time course of the cGMP cytoplasmic concentration for human rods and cones. Shown are simulations of the expected spatial pattern of cGMP concentration loss in OS caused by continuous cGMP hydrolysis in a single compartment. cGMP destruction in the active compartment starts at time 0 and is sustained for different periods, as labeled. We elected to compare human rods and cones because they are rather similar in size (Tables 3 and 4) and their cGMP concentration in the dark can be reasonably estimated. Considering that
2% of the cGMP-gated channels are active in darkness and given the known Hill equation relationship between channel activity and cGMP concentration (Dhallan et al., 1992
; Wissinger et al., 1997
; Peng et al., 2003
), the nucleotide concentration in human ROS is
17 µM (270 cGMP molecules/compartment) and 4.3 µM in cones (59 cGMP molecules/compartment at the tip and 189 at the base). To compare rods and cones, we explored periods of hydrolysis proportional to the cell's photocurrent time to peak (tp). For both photoreceptors, the curves shown were computed for 0.2 tp (red), 0.4 tp (blue), 0.6 tp (green), 0.8 tp (orange), and