| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Department of Biomedical Engineering, Washington University, St. Louis, Missouri
Correspondence: Address reprint requests to Jin-Yu Shao, PhD, Dept. of Biomedical Engineering, Washington University in St. Louis, Campus Box 1097, Rm. 290E, Uncas A. Whitaker Hall, 1 Brookings Dr., St. Louis, MO 63130-4899. Tel.: 314-935-7467; Fax: 314-935-7448; E-mail: shao{at}biomed.wustl.edu.
| ABSTRACT |
|---|
|
|
|---|
| INTRODUCTION |
|---|
|
|
|---|
Studies on membrane tether extraction in general can help us understand the association between the leukocyte membrane and its underlying cytoskeleton, which is particularly relevant to the processes of secretion and signaling (Hochmuth et al., 1996
; Sheetz and Dai, 1996
; Hochmuth and Marcus, 2002
). Tethers have been extracted from lipid vesicles (Waugh, 1982
) and from various living cells, including neutrophils (Shao and Hochmuth, 1996
; Shao and Xu, 2002
), erythrocytes (Hochmuth et al., 1973
, 1982
), neuronal growth cones (Dai and Sheetz, 1995
; Hochmuth et al., 1996
), and outer hair cells (Li et al., 2002
). For single tether extraction from all these cell types, it has been shown that (Evans and Yeung, 1994
; Yeung, 1994
; Dai and Sheetz, 1995
; Hochmuth et al., 1996
; Shao and Hochmuth, 1996
)
![]() | (1) |
eff is the effective viscosity, and Ut is the tether-growth velocity. The threshold force F0 is determined by the intrinsic membrane surface tension, the membrane bending rigidity, and the membrane-cytoskeleton adhesion energy. In addition,
eff is determined by the intrinsic membrane surface viscosity, the relative interbilayer slip, and the membrane slip relative to the cytoskeleton (Evans and Yeung, 1994
For single tether extraction from passive neutrophils, F0 = 45 pN and
eff = 1.8 pN · s/µm (Shao and Hochmuth, 1996
). Stimulation of the cells with chemokines such as interleukin-8 (IL-8) or phorbol myristate acetate (PMA) resulted in a threshold force twice as large as that for passive neutrophils and dramatically decreased the effective viscosity (Shao and Xu, 2002
). Because of the high surface density of leukocyte microvilli, more than one microvillus could be in contact with the endothelium at the onset of rolling and double or multiple tethers could be extracted. In fact, double or multiple tethers have to be present at least intermittently during the rolling process because a stable rolling cannot be achieved otherwise. Although double tethers drawn from neutrophils have been observed in some flow chamber studies (Schmidtke and Diamond, 2000
; Park et al., 2002
) and in our previous micropipette experiments (Shao and Hochmuth, 1996
; Shao and Xu, 2002
), to date, the relationship between the pulling force and tether-growth velocity is still unknown for double tethers extracted from passive or stimulated neutrophils. It is important to determine this relationship so that the detailed force history of each adhesive bond can be calculated during the rolling process. Equally important, the same relationship for single and double tether extraction from CD4+ T-lymphocytes (chosen to avoid variation among different subpopulations of lymphocytes) is also unknown. This study will provide us some valuable information on the mechanical properties of these cells as well as the basis for their rolling and recirculation. Using the micropipette-aspiration technique (MAT), for the first time we determined these previously-unknown properties of double tether extraction from neutrophils as well as single and double tether extraction from CD4+ T-lymphocytes.
| MATERIALS AND METHODS |
|---|
|
|
|---|
20°C). Thereafter, the tube was cut at a point in the gradient region that was near but free of erythrocytes and neutrophils (a white layer sandwiched between the gradient solution and erythrocytes). The erythrocytes and neutrophils were discarded. The remaining cells were mixed with 0.1-ml 50% autologous plasma-HBSS solution (modified endotoxin-free Hanks' balanced salt solution; no Ca2+ or Mg2+; buffered with 25 mM Hepes; pH = 7.4; Sigma) and incubated with FITC-conjugated monoclonal mouse anti-human CD4 (Sigma) at 37°C for 15 min in order for them to be differentiated from other subpopulations of lymphocytes. Finally, the cells were washed twice with 1.1-ml HBSS solution at 2,700 x g for 5 min at room temperature (
20°C), resuspended in a 0.1-ml 50% autologous plasma-HBSS solution, and transferred to the experimental chamber. During the experiments, CD4+ T-lymphocytes were identified by using fluorescence microscopy. Without any other treatment, the cells were spherical under the microscope and not appear to be activated by the labeling. For stimulation experiments, cells were treated with 25 ng/ml IL-8 (R&D Systems, Minneapolis, MN) or 50 ng/ml PMA (Sigma) in the experimental chamber as described previously (Shao and Xu, 2002
Latex beads coated with goat anti-mouse IgG antibodies (
8.3 µm in diameter; Sigma) were washed twice in PBS and incubated with mouse anti-human CD162 or CD18 (PharMingen, San Diego, CA) for tether-extraction experiments from passive or stimulated cells, respectively. The beads were then stored at 4°C and washed twice with PBS before use. During the incubation, the concentration of the primary antibody (
10 µg/ml) was large enough to saturate all the binding sites of the secondary antibody on the bead surface. The beads used in this study were the same as the ones used in two previous studies (Shao and Hochmuth, 1999
; Levin et al., 2001
), where the site density of the primary antibody was determined to be
220/µm2 with two independent methods: the micropipette technique and flow cytometry.
Tether extraction with the MAT
Tether-extraction experiments from neutrophils and CD4+ T-lymphocytes were conducted with the MAT (Shao and Xu, 2002
). A video micrograph from one of the lymphocyte experiments is shown in Fig. 1. The micropipette on the left is shown containing an antibody-coated bead, which is the force transducer of the MAT. The pipette on the right is shown holding a CD4+ T-lymphocyte at the mouth of the left pipette. At the beginning of an experiment, a precisely-controlled aspiration pressure (
p < 0) is applied inside the left pipette, which causes the bead to move initially to the left. Then a positive internal pressure is superimposed, and the bead is driven to the right until it contacts the cell. After the bead is in contact with the cell for a certain period of time, the positive pressure is removed and the negative aspiration pressure (
p) is imposed to pull the bead again to the left. If the contact does not result in adhesion between the bead and cell, the bead translates freely to the left at its "free motion velocity (Uf)". If, on the contrary, adhesion occurs during the contact, tether extraction and extension ensues under the action of the aspiration pressure, which is often of sufficient magnitude for double tether extraction. One or two tethers may occur. The leftward velocity of withdrawal of the bead-transducer (tether-growth velocity, Ut) is a function of
p and the number of tethers formed. Several typical modes of bead displacement versus time are shown in Fig. 2, ac, indicating zero, one, and two tethers formed in this process, respectively. The corresponding pulling force (F) can be calculated from (Shao and Hochmuth, 1996
)
![]() | (2) |
![]() | (3) |
3 min. Since the pressure in the experimental chamber changes slowly over time, the zero pressure has to be verified frequently, usually before a new cell-bead pair is used. The negative aspiration pressures (
p) used in our experiments ranged from 2 pN/µm2 to 12 pN/µm2. All experiments were recorded on an S-VHS videotape and analyzed as described below.
|
|
| RESULTS |
|---|
|
|
|---|
eff are not different for single tether extraction from CD4+ T-lymphocytes and neutrophils
Almost all tethers grew at constant velocity under a constant aspiration pressure. With the MAT, single tether extraction was typically inferred from a slow bead translation followed by a free faster bead translation (Uf) indicating rupture of the adhesive bond between the bead and cell (Shao and Hochmuth, 1996
; Shao and Xu, 2002
). Furthermore, an adhesion frequency, defined as the percentage of adhesive events in the total bead-cell contact trials, <20%, was also taken to be an indicator of single receptor-ligand interactions and hence single tether extractions. Fig. 3, a and b, compare the correlations between the tether force and tether-growth velocity for single and double tethers drawn from passive CD4+ T-lymphocytes and passive neutrophils, respectively. For CD4+ T-lymphocytes, the threshold force (intercept) necessary to extract a single tether was found to be 46 pN, and the effective membrane surface viscosity (slope divided by 2
) was found to be 1.55 pN · s/µm. These values are essentially the same as those derived from the correlation for single tethers from passive neutrophils (Fig. 3 b). The results for single tether extraction from passive neutrophils are in good agreement with those in the literature (Shao and Hochmuth, 1996
; Shao and Xu, 2002
).
|
eff double for double tether extraction from CD4+ T-lymphocytes and neutrophils
1,
2, and
3 (defined in Fig. 2) are plotted against their corresponding pulling forces for passive CD4+ T-lymphocytes. It should be noted that, during double tether extraction, the pulling force was not a constant. When double tethers were present, the force was larger than the force after one of the tethers was broken. Had the other tether also been broken by this larger force,
3 would have been smaller. Consequently, the adhesion lifetime under this larger force should lie somewhere between
2 and
3. As shown in Fig. 4, even
2 is larger than
1 under similar pulling forces. Therefore, we can conclude that double bonds were indeed formed in our double tether experiment with passive CD4+ T-lymphocytes. For stimulated lymphocytes and passive or stimulated neutrophils, the same conclusion can be drawn (data not shown).
|
|
|
|
| DISCUSSION |
|---|
|
|
|---|
8 µm in total length (from the instant of adhesion to the instant when the second tether was broken). This value is comparable to the average tether length of the single tethers extracted from these cells at low adhesion frequency, where no slope change was observed (data not shown; this is also true for other cells). Likewise, the slope change shown in Fig. 2 c is not caused by two different receptor pools or one receptor population with two different linkages to the cytoskeleton (one results in single tether extraction and the other results in double tether extraction) either. If these two different receptor pools or linkages existed, we would have observed the same slope change when single tethers were extracted at low adhesion frequency.
Membrane tethers extracted from fibroblasts do not have F-actin inside (Raucher et al., 2000
), which indicates that the cytoskeleton is not deformed or dislocated during tether extraction. This is likely also the case for the lymphocytes and neutrophils studied in this article. If tether extraction involves deforming the cytoskeleton (a network of rodlike cytoskeletal components), we should expect that the tether-growth velocity would become smaller and smaller under a constant pulling force. The fact that we obtained a constant tether-growth velocity under a constant pulling force indicates that no cytoskeletal component was dislocated, so even a receptor with two different linkages to the cytoskeleton would not cause the slope change in Fig. 2 c. Therefore, the slope change in Fig. 2 c is very likely due to double tether extraction.
For single tether extraction from passive neutrophils at large forces (>100 pN), it is possible that the local structure at the junction of the tether and cell (mainly the separation radius) will cause a decrease in the effective viscosity (Marcus and Hochmuth, 2002
). According to Marcus and Hochmuth (2002)
, the smaller the separation radius (corresponding to smaller pulling forces), the larger the effective viscosity. If this were the reason for the slope change shown in Fig. 2 c, it would imply that, after the slope change, the separation radius became smaller and the effective viscosity became larger because a smaller force was present (corresponding to the faster bead motion as shown in Fig. 2 c and Eq. 2). However, what we found was that the effective viscosity became smaller after the slope change (Figs. 3, 5, and 6). This contradiction, in addition to the fact that the slope change has nearly never been observed in our low adhesion-frequency (single tether extraction) experiments, indicates that the slope change in Fig. 2 c is not caused by the change in the local structure of the cell.
Lymphocytes (
7.5 µm in diameter) are smaller than neutrophils (
8.3 µm in diameter) and have a relatively larger nucleus (44% of cell volume) than neutrophils (21% of cell volume) (Waugh and Hochmuth, 1995
). We did not know whether lymphocytes and neutrophils would exhibit different mechanical properties governing tether extraction because of their different cellular and nuclear sizes. In this study, we found virtually no difference in the mechanics of tether extraction (single or double) from these passive cells. Both passive CD4+ T-lymphocytes and neutrophils have the same effective viscosity (
1.55 pN · s/µm). They also have the same total adhesion energy (
130 pN/µm) as determined from the threshold force (Hochmuth and Marcus, 2002
). The cortical tension of lymphocytes, determined to be
35 pN/µm (Waugh and Hochmuth, 1995
), is very close to that of neutrophils (2435 pN/µm) (Evans and Yeung, 1989
; Needham and Hochmuth, 1992
; Tsai et al., 1993
, 1994
). These results demonstrate that these two types of leukocyte possess the same overall intrinsic mechanical properties as manifested by membrane tension, bending, membrane viscosity, and dynamic membrane-cytoskeleton association.
Because lymphocytes are smaller than neutrophils, they would be expected to experience different tether forces under the same blood flow conditions when rolling on the vascular endothelium. By using a simple biophysical model of leukocyte rolling (Shao et al., 1998
), we were able to estimate the variation of the bond force in a single tether being extracted from either a lymphocyte or a neutrophil rolling under the action of the same shear stress. As shown in Fig. 7, at a wall shear stress of 0.08 pN/µm2, the tensile force on a single tether pulled from a lymphocyte (with an initial microvillus length of 0.35 µm) decreases from
120 pN to
50 pN in 1 s. Under the same shear stress, the tensile force on a single tether from a neutrophil (with the same initial microvillus length) decreases from
160 pN to
60 pN in 1 s (Shao et al., 1998
).
|
60 pN to
43 pN in 1 s. Under the same shear stress, the tensile force on one of the two tethers from a neutrophil decreases from
80 pN to
54 pN in 1 s. Obviously, the presence of double tethers can decrease the force on each bond much more effectively than single tethers under the same shear stress. Hence, for both lymphocytes and neutrophils, the extraction and subsequent extension of single or double tethers can result in a dramatic decrease in the stress tending to break the bond between the leukocyte and endothelium. This stress relief prolongs the bond lifetime and lowers the chance of extraction of selectins from the rolling cell surface and hence helps keep the cell linked to the endothelium until firm arrest and diapedesis occur.
The transition of rolling to firm adhesion of a leukocyte on the endothelium is regulated by specific chemokines released locally by endothelial cells (Springer, 1995
). These chemokines bind to their G-protein-coupled receptors on circulating leukocyte surfaces and hence induce adhesion and migration in a manner analogous to adhesion molecules (Olson and Ley, 2002
). IL-8 and PMA are commonly-used in the study of leukocyte functions. IL-8 is a potent neutrophil chemoattractant that can bind the receptors on neutrophils. IL-8 has various effects on neutrophils such as pseudopodium extraction, degranulation, and respiratory burst. Our results demonstrate further that IL-8 affects the mechanics of tether extraction (single and double) from neutrophils. Some controversy exists about whether IL-8 has an impact on the migration of T-lymphocytes. Recent findings suggest that IL-8 activates neutrophils to release some prestored chemotactic products from their granules that can mediate the migration of human T-lymphocytes (Taub et al., 1996
; Wang et al., 1996
). Nevertheless, our results indicate that IL-8 has no direct effect on tether extraction from T-lymphocytes since our procedure for isolating lymphocytes ensured that there were no neutrophils in the experimental chamber.
On the other hand, PMA can activate protein kinase C and induce respiratory burst and actin polymerization in both neutrophils and lymphocytes. Our results show that PMA decreases the effective viscosity and increases the total adhesion energy (as determined from the increased threshold force) of both types of leukocyte. It has also been postulated that IL-8 and PMA both cause a decrease in the membrane-cytoskeletal slip viscosity of neutrophils, but not the membrane viscosity nor interbilayer slip viscosity (Shao and Xu, 2002
). The decrease in the membrane-cytoskeletal slip viscosity will thus result in dramatic decrease of the effective viscosity when tethers are extracted from neutrophils. Our results show that PMA, but not IL-8, has similar effects on CD4+ T-lymphocytes.
When double tethers were extracted in our experiment, there were probably just two antibody-receptor bonds between the bead and cell. If there were more than two bonds, it would likely result in either no tether extraction or more tethers (
3) extracted. The initial bond formation in the contact area was a random process, so the locations of these two bonds were likely not too close to each other within an average contact area of 12 µm2. This indicates that they would likely be located on two different microvilli on passive lymphocytes and neutrophils or at an average distance of a few hundred nanometers on treated cells. Therefore, it is not surprising that the correlation between F and Ut for double tether extraction from these leukocytes (passive or treated) is shifted upward, relative to that of single tether extraction (Table 1), in accordance with an approximate doubling of threshold force and effective viscosity. This indicates that double tethers generally do not compete for the lipid membrane source even though the tethers could be 20- or 30-µm long. This seems reasonable considering that there is so much excess membrane material in these microvillus-rich leukocytes and that individual tethers are only tens of nanometers in diameter. During the rolling of leukocytes on the endothelium, double tethers occur occasionally as demonstrated in flow chamber studies (Schmidtke and Diamond, 2000
; Park et al., 2002
). Our experimentally-determined F versus Ut relationship indicates that these two tethers are very likely independent of each other while being extracted.
| ACKNOWLEDGEMENTS |
|---|
|
|
|---|
This work was supported by the National Institutes of Health (R01 HL069947).
Submitted on June 25, 2004; accepted for publication September 30, 2004.
| REFERENCES |
|---|
|
|
|---|
Dai, J., and M. P. Sheetz. 1995. Mechanical properties of neuronal growth cone membrane studied by tether formation with laser optical tweezers. Biophys. J. 68:988996.
Davenpeck, K. L., M. E. Brummet, S. A. Hudson, R. J. Mayer, and B. S. Bochner. 2000. Activation of human leukocytes reduces surface P-selectin glycoprotein ligand-1 (PSGL-1, CD162) and adhesion to P-selectin in vitro. J. Immunol. 165:27642772.
Diamond, M. S., and T. A. Springer. 1993. A subpopulation of mac-1(CD11b/CD18) molecules mediates neutrophil adhesion to ICAM-1 and fibrinogen. J. Cell Biol. 120:545556.
Erlandsen, S. L., S. R. Hasslen, and R. D. Nelson. 1993. Detection and spatial distribution of the ß2 integrin (Mac-1) and L-selectin (LECAM-1) adherence receptors on human neutrophils by high-resolution field emission SEM. J. Histochem. Cytochem. 41:327333.[Abstract]
Evans, E., and A. Yeung. 1989. Apparent viscosity and cortical tension of blood granulocytes determined by micropipette aspiration. Biophys. J. 56:151160.
Evans, E., and A. Yeung. 1994. Hidden dynamics in rapid changes of bilayer shape. Chem. Phys. Lipids. 73:3956.[CrossRef]
Hochmuth, R. M., and W. D. Marcus. 2002. Membrane tethers formed from blood cells with available area and determination of their adhesion energy. Biophys. J. 82:29642969.
Hochmuth, R. M., N. Mohandas, and P. L. J. Blackshear. 1973. Measurement of the elastic modulus for red cell membrane using a fluid mechanical technique. Biophys. J. 30:747762.
Hochmuth, R. M., J.-Y. Shao, J. Dai, and M. P. Sheetz. 1996. Deformation and flow of membrane into tethers extracted from neuronal growth cones. Biophys. J. 70:358369.
Hochmuth, R. M., H. C. Wiles, E. A. Evans, and J. T. McCown. 1982. Extensional flow of erythrocyte membrane from cell body to elastic tether: II. Experiment. Biophys. J. 39:8389.
Levin, J. D., H. P. Ting-Beall, and R. M. Hochmuth. 2001. Correlating the kinetics of cytokine-induced E-selectin adhesion and expression on endothelial cells. Biophys. J. 80:656667.
Li, Z., B. Anvari, M. Takashima, P. Brecht, J. H. Torres, and W. E. Brownell. 2002. Membrane tether formation from outer hair cells with optical tweezers. Biophys. J. 82:13861395.
Marcus, W. D., and R. M. Hochmuth. 2002. Experimental studies of membrane tethers formed from human neutrophils. Ann. Biomed. Eng. 30:12731280.[CrossRef][Medline]
Moore, K. L., K. D. Patel, R. E. Bruehl, F. Li, D. A. Johnson, H. S. Lichenstein, R. D. Cummings, D. F. Bainton, and R. P. McEver. 1995. P-selectin Glycoprotein ligand-1 mediates rolling of human neutrophils on P-selectin. J. Cell Biol. 128:661671.
Needham, D., and R. M. Hochmuth. 1992. A sensitive measure of surface stress in the resting neutrophil. Biophys. J. 61:16641670.
Olson, T. S., and K. Ley. 2002. Chemokines and chemokine receptors in leukocyte trafficking. Am. J. Physiol. Regul. Integr. Comp. Physiol. 283:R728.
Park, E. Y., M. J. Smith, E. S. Stropp, K. R. Snapp, J. A. DiVietro, W. F. Walker, D. W. Schmidtke, S. L. Diamond, and M. B. Lawrence. 2002. Comparison of PSGL-1 microbead and neutrophil rolling: microvillus elongation stabilizes P-selectin bond clusters. Biophys. J. 82:18351847.
Raucher, D., T. Stauffer, W. Chen, K. Shen, S. Guo, J. D. York, M. P. Sheetz, and T. Meyer. 2000. Phosphatidylinositol 4,5-bisphosphate functions as a second messenger that regulates cytoskeleton-plasma membrane adhesion. Cell. 100:221228.[CrossRef][Medline]
Schmidtke, D. W., and S. L. Diamond. 2000. Direct observation of membrane tethers formed during neutrophil attachment to platelets or P-selectin under physiological flow. J. Cell Biol. 149:719729.
Shao, J.-Y., and R. M. Hochmuth. 1996. Micropipette suction for measuring piconewton forces of adhesion and tether formation from neutrophil membranes. Biophys. J. 71:28922901.
Shao, J.-Y., and R. M. Hochmuth. 1999. Mechanical anchoring strength of L-selectin, ß2 integrins and CD45 to neutrophil cytoskeleton and membrane. Biophys. J. 77:587596.
Shao, J.-Y., H. P. Ting-Beall, and R. M. Hochmuth. 1998. Static and dynamic lengths of neutrophil microvilli. Proc. Natl. Acad. Sci. USA. 95:67976802.
Shao, J.-Y., and J. Xu. 2002. A modified micropipette aspiration technique and its application to tether formation from human neutrophils. J. Biomech. Eng. 124:388396.[CrossRef][Medline]
Sheetz, M. P., and J. Dai. 1996. Modulation of membrane dynamics and cell motility by membrane tension. Trends Cell Biol. 6:8589.[CrossRef][Medline]
Springer, T. A. 1995. Traffic signals on endothelium for lymphocyte recirculation and leukocyte emigration. Annu. Rev. Physiol. 57:827872.[CrossRef][Medline]
Taub, D. D., M. Anver, J. J. Oppenheim, D. L. Longo, and W. J. Murphy. 1996. T-lymphocyte recruitment by interleukin-8 (IL-8). IL-8-induced degranulation of neutrophils releases potent chemoattractants for human T-lymphocytes both in vitro and in vivo. J. Clin. Invest. 97:19311941.[Medline]
Tsai, M. A., R. S. Frank, and R. E. Waugh. 1993. Passive mechanical behavior of human neutrophils: power-law fluid. Biophys. J. 65:20782088.
Tsai, M. A., R. S. Frank, and R. E. Waugh. 1994. Passive mechanical behavior of human neutrophils: effect of cytochalasin B. Biophys. J. 66:21662172.
Wang, J. M., L. Xu, W. J. Murphy, D. D. Taub, and O. Chertov. 1996. IL-8-induced T-lymphocyte migration: direct as well as indirect mechanisms. Methods. 10:135144.[CrossRef][Medline]
Waugh, R. E. 1982. Surface viscosity measurements from large bilayer vesicle tether formation: II. Experiments. Biophys. J. 38:2937.
Waugh, R. E., and R. M. Hochmuth. 1995. Mechanics and deformability of hematocytes. In The Biomedical Engineering Handbook. J. D. Bronzino, editor. CRC Press, Boca Raton, FL. 474486.
Yago, T., A. Leppanen, H. Qiu, W. D. Marcus, M. U. Nollert, C. Zhu, R. D. Cummings, and R. P. McEver. 2002. Distinct molecular and cellular contributions to stabilizing selectin-mediated rolling under flow. J. Cell Biol. 158:787799.
Yeung, A. K. C. 1994. Mechanics of intermonolayer coupling in fluid surfactant bilayers. PhD dissertation. Dept. of Physics, University of British Columbia, Vancouver, Canada.
Zar, J. H. 1999. Biostatistical Analysis. Prentice Hall, Upper Saddle River, N.J.
This article has been cited by other articles:
![]() |
J. Schmitz, M. Benoit, and K.-E. Gottschalk The Viscoelasticity of Membrane Tethers and Its Importance for Cell Adhesion Biophys. J., August 1, 2008; 95(3): 1448 - 1459. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Girdhar and J.-Y. Shao Simultaneous Tether Extraction from Endothelial Cells and Leukocytes: Observation, Mechanics, and Significance Biophys. J., December 1, 2007; 93(11): 4041 - 4052. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Liu, C. J. Goergen, and J.-Y. Shao Effect of Temperature on Tether Extraction, Surface Protrusion, and Cortical Tension of Human Neutrophils Biophys. J., October 15, 2007; 93(8): 2923 - 2933. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Girdhar, Y. Chen, and J.-Y. Shao Double-Tether Extraction from Human Umbilical Vein and Dermal Microvascular Endothelial Cells Biophys. J., February 1, 2007; 92(3): 1035 - 1045. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Yu and J.-Y. Shao Simultaneous Tether Extraction Contributes to Neutrophil Rolling Stabilization: A Model Study Biophys. J., January 15, 2007; 92(2): 418 - 429. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sun, J. S. Graham, B. Hegedus, F. Marga, Y. Zhang, G. Forgacs, and M. Grandbois Multiple Membrane Tethers Probed by Atomic Force Microscopy Biophys. J., December 1, 2005; 89(6): 4320 - 4329. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |