| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||


* Institut Fresnel, MOSAIC Group, CNRS UMR 6133-Université Paul Cézanne Aix-Marseille III, Domaine Universitaire de Saint Jérôme, F-13397 Marseille Cedex 20, France; and
Centre d'Immunologie de Marseille-Luminy, MOSAIC group, CNRS UMR 6102-INSERM UMR 631-Université de la Méditerranée, Parc Scientifique de Luminy, Case 906, F-13288 Marseille Cedex 9, France
Correspondence: Address reprint requests to Pierre-François Lenne, Institut Fresnel, MOSAIC Group, CNRS UMR 6133-Université Paul Cézanne Aix-Marseille III, Domaine Universitaire de Saint Jérôme, F-13397 Marseille Cedex 20, France. Tel: 33-491-28-8049; Fax: 33-491-28-8067; E-mail: lenne{at}fresnel.fr.
| ABSTRACT |
|---|
|
|
|---|
| INTRODUCTION |
|---|
|
|
|---|
This lack of data principally results from the absence of appropriate tools. Indeed, optical tools such as confocal microscopy have not enabled the observation of separate domains and suggest that the size of the domains is below the optical resolution (<200 nm) (8
). Alternative approaches, such as single-particle tracking (2
,9
,10
) and optical tweezers (11
), have a better spatial resolution and have shed a new light on this question. Single particle tracking and single dye tracking have proved to be valuable tools to measure the diffusion properties in membranes and to unravel hop diffusion. Nevertheless they suffer from two drawbacks: i), in most cases, these experiments require the labeling of a single molecule with a bead or a gold colloidal particle, which proves to be difficult; and ii), a large number of trajectories need to be recorded and analyzed to fit statistical criteria. One must be cautious in interpreting experimental results on a few diffusing particles, since distributions of hopping rates may be broad (12
) and the detection of transiently confining structures thus requires the study of many molecules. In this respect, FCS may appear as a more appropriate technique since it analyzes an ensemble of molecules diffusing in the detection volume. Although FCS studies have reported anomalous diffusion in live cells (13
), it has not been applied to study confinement in membranes. Here, we detail the rationales of the FCS analysis performed at various spatial scales to probe the submicron organization of the cell membrane. The method that we proposed recently (14
) has been independently implemented in another context by Okamato's group (15
,16
).
FCS is a mature and powerful technique for measuring diffusion coefficients and chemical reaction rates both in vivo and in vitro (17
). It measures the spontaneous fluctuations of fluorescence in an open volume defined by a focused laser and confocal optics. These fluctuations can arise in particular from the diffusion of fluorescent molecules into or out of this open sampling volume. To analyze statistically the fluctuations, one computes the time ACF, which provides information on diffusion properties.
Though the size of the detection volume is diffraction limited, the ACF can be altered by processes occurring on smaller spatial scales. It has been recently shown (18
,19
) that confinement in small cell compartments modifies ACFs computed by FCS. In these studies, analytical formula taking into account the volume and geometry of confined regions are proposed to fit experimental ACFs. Although this approach might be useful to determine diffusion coefficients in small volume compartments, its validity is restricted to simple geometries and its implementation is difficult without any a priori knowledge of the geometry.
In this article, we suggest observables that can be obtained from FCS and that are useful to detect confinement in microdomains. First, we emphasize the problems encountered when fitting ACFs, and point out the need for measuring the so-called FCS diffusion laws, instead of only interpreting the shape of ACFs measured at a single size of waist.
The manuscript is organized as follows: we first introduce and show FCS experimental diffusion laws for a lipid and a transmembrane protein. The studied lipid is FL-GM1, which is considered to be a raft marker, and the transmembrane protein is TfR-GFP, diffusion of which is supposed to be hindered by the cytoskeleton meshwork. Interestingly, these two constituents exhibit two different FCS diffusion laws. To explain these results, we simulate in the second part different diffusion processes, which could explain the FCS diffusion laws that have been measured experimentally. We first address the basic issue of confinement of a molecule freely diffusing in an impermeable or permeable 2D domain, and then focus on restricted diffusion in multiple microdomains in mosaic geometries. Two geometries are explored more accurately: the first one accounts for isolated microdomains, in which molecules can partition dynamically ("partitioning microdomains"); and the second accounts for the actin meshwork. Finally, the experimental FCS diffusion laws are reinterpreted thanks to the new light shed by the simulations.
| MATERIALS AND METHODS: |
|---|
|
|
|---|
|
Fluorescent conjugated lipid probe BODIPY-ganglioside GM1 (FL-GM1) (Molecular Probes, Eugene, OR) is incorporated in the plasma membrane by a lipid exchange procedure (20
).
To obtain the TfR-GFP recombinant protein expression, cells are transiently transfected with a mixture of the plasmid and ExGen 500 reagent (Euromedex, Souffelweyersheim, France).
FCS measurements are performed at 37°C at least 16 h after each of these incorporations.
FCS setup
Confocal fluorescence microscopy and fluorescence correlation spectroscopy are performed on a custom apparatus, which has been developed from an Axiovert 200 inverted microscope (Zeiss, Jena, Germany). The excitation light of the 488 nm line of an Ar+-ion laser is focused onto the sample through a Zeiss C-Apochromat 40x, numerical aperture =1.2, water immersion objective. The fluorescence is collected by the same objective, separated from the excitation light by a dichroic mirror, then split by a 50/50 cube splitter and sent onto two avalanche photodiodes through 525565 nm bandpass filters. Cross correlation between the two channels is preferred to autocorrelation of one channel, since it reduces artifacts due to the dead time of each detector and after pulses. A confocal pinhole (20 or 50 µm in diameter) reduces the out-of-plane fluorescence. Precise positioning of the cell membrane in the confocal volume is obtained by moving the sample step-by-step with a three-axis piezo-scanner, which is controlled by a digital controller (Physik Instrumente, Karlsruhe, Germany). Scanning softwares are written with LabView (National Instruments, Austin, TX).
FCS measurements are performed by illuminating the sample with an excitation power of 3.5 µW at the back-aperture of the objective. Auto-correlation is processed by a hardware correlator (ALV-GmBH, Langen, Germany). Data are analyzed with built-in functions of IgorPro (Wavemetrics, Lake Oswego, OR).
Fitting of autocorrelation functions
In a standard FCS experiment, a diffusion measurement is carried out for a single size of the confocal volume, i.e., a single value of the laser beam transversal waist w at the focal plane of the focusing objective. The diffusion coefficient is determined from the measurement of the apparent diffusion time
of a fluorescent molecule through the confocal volume, which is defined as the FWHM of the ACF. For free translational two-dimension diffusion,
matches the actual diffusion time through the confocal volume
where
is the microscopic diffusion coefficient of the fluorescent molecule in the plane of diffusion. If the diffusion is free, and in the case of a Gaussian approximation of the detectable emission intensity distribution, the ACF is given by (21
)
![]() | (1) |
For anomalous diffusion, the mean-square displacement of particles is no longer proportional to time t as for free diffusion, but rather to t
, with 0 <
1. This diffusion mode corresponds to molecules diffusing in the presence of multiple energy potential traps with binding energies that vary over wide ranges of time and space (22
). Anomalous diffusion can also result from diffusion on a percolating cluster at the threshold. In FCS, if diffusion is anomalous,
can be determined from the ACF, which is given by
![]() | (2) |
is equal to
if
= 1.
When diffusion is free, then
= 1. We will show in the Experimental Evidence section that the converse is false.
Size of the confocal volume
The size of the confocal volume can be controlled by selecting either with a diaphragm or a variable telescope (14
,16
) the lateral extension of the laser excitation beam falling onto the back-aperture of the microscope objective. Similar approaches have been implemented in fluorescence recovery after photobleaching experiments (23
,24
).
The size of the confocal volume can be inferred from the free diffusion time
of a fluorophore in the open confocal volume, and its known diffusion coefficient (Fig. 1). Here, Rh6G, of which the diffusion coefficient is known (
) (21
) is used to calibrate the size of the confocal volume. The radius of the illuminated observation area can be modulated between 190 and 400 nm. The Rh6G diffusion time through the confocal volume obtained by fulfilling the rear-aperture of the microscope objective allows the determination of the smallest waist accessible with our setup: wmin=190 nm. In all experiments, the excitation power at the back-aperture of the objective is kept constant for all waist sizes. To validate the calibration protocol of the waists in the context of 2D diffusion measurements, we have studied the diffusion of Bodipy-PC probes freely diffusing in giant unilamellar vesicles (14
). We have checked that the determination of the diffusion coefficient is correct and independent on the size of the waist as expected for free 2D diffusion.
|
where x and y are the Cartesian coordinates originating at the center of the area A. Depending on the objective back-aperture filling used, w can vary from 200 nm to 400 nm in a standard FCS setup.
|
The random walk is performed as follows:
At each time step
t0, the particle performs a jump (
X,
Y), which is determined by two independent random variables with a Gaussian distribution centered on 0 and a standard deviation
The jump length
is therefore a random variable with a standard deviation
The microscopic diffusion coefficient Dmicro is related to
by
Typically, 1091010 steps are calculated for a trajectory. The mean elementary jump length is kept small (from 1/100 to 1/20) with respect to the size of domains (see below).
Detection and ACF
At each time step, the detected intensity is computed assuming a Poisson distribution; the number of detected fluorescence photons nph for a particle at position (x, y) is given by a random variable following a Poisson distribution function with parameter
where ß describes the collection efficiency of the setup (25
). To analyze fluorescence fluctuations, the normalized time autocorrelation function ACF is defined as
![]() | (3) |
represents a time average.
In our simulations, the ACF is calculated either after the whole trajectory of the particle has been obtained or in parallel. The software correlator used to compute the ACFs follows the architecture proposed by (26
) and described in (25
). It has a logarithmic timescale, each channel having an individual sampling time and delay time.
Domains and barriers
Domains are considered to be regions in which the diffusion is free but restricted by barriers. These barriers can represent physical obstacles (cytoskeleton fences) or energy barriers (phase separations). Barriers are considered to be infinitely thin: they are lines that the molecule can cross with a given probability P. The probability P of crossing a barrier is independent of time. External boundaries of the surface A are impermeable. When the molecule hits the external boundaries, it is reflected at the wall.
When the molecule hits a barrier, a number rand is drawn at random between 0 and 1 and compared to the probability P of crossing the barrier. rand is generated by a number generator of Park and Miller with Bays-Durham shuffle and added safeguards, and has a period of
2 x 109 (27
). If rand < P, the barrier is crossed; if not, the molecule remains at its previous position. This condition seems appropriate for biological membranes that are viscous.
Confinement in a permeable domain: definition of the confinement strength
This section aims at defining the input parameters and the associated physical parameters that are relevant to study the transient confinement in domains. In particular, we define the confinement time and the confinement strength, and give their expression as functions of the input parameters.
A circular permeable domain is now embedded in a square area. We define the confinement time
as the average time needed by a molecule placed at the center of the domain to escape from it. We have studied the ratio of the confinement time over the free diffusion time in the domain
as a function of P (Fig. 3).
|
![]() | (4) |
This curve has the same shape as that derived by Saxton for the mean escape time from a corral (12
). Nevertheless, different definitions for the escape time and the diffusion time were chosen in Saxton (12
), which were more adapted to a single-particle tracking study, leading to different values for the two parameters A and B.
With our definition, parameter A is equal to 1, which means that the confinement time in a domain surrounded by fully permeable barriers is equal to the free diffusion time in the domain. When the probability P of crossing the barrier is <1, the confinement time gets longer than the diffusion time. The ratio
is the key parameter expressing the height of the barrier that molecules have to pass. In the following, we will define the confinement strength as
It has to be noted that this confinement strength is not only a function of P, but also a function of the mean diffusion step length
and the radius r of the domain (see Eq. 4).
One may wonder if
is an accessible parameter, not only with single-particle analysis, but also from a FCS study. To assess this point, we simulate a FCS experiment with a laser spot centered on the permeable domain. The laser beam waist w is chosen equal to the radius r of the domain, so that the apparent diffusion time
represents the average time spent by a molecule in the domain. In this case, we found that
matches
as a function of P. As a result,
is still easy to determine with a FCS analysis.
In the case where the confinement area is a square, the value of the radius of the circle is simply replaced in Eq. 4 by the average length between the center of the square and the side of the square. This length is equal to
where
is the angle that a line from the center of the square makes with one side. Doing the same analysis leads to coefficients A = 1 and B = 1.34.
Simulations and data analysis
We have implemented the simulations in C++ (Microsoft Visual C++, Version 6.0). They are run on a PC (Pentium III processor). Results have been analyzed and fitted with Igor Pro software (Wavemetrics).
| EXPERIMENTAL EVIDENCE: NEED FOR FCS DIFFUSION LAW MEASUREMENTS |
|---|
|
|
|---|
This section points out the need for performing FCS diffusion law measurements, instead of the sole study of the shape of the autocorrelation function at a single waist.
Experimental autocorrelation functions
Confocal images of COS-7 cells after staining with fluorescent lipids FL-GM1 showed a uniform distribution of the probes in the plasma membrane and a vesicular staining figured by intracellular small dots (Fig. 4 A). Confocal images for TfR-GFP expressing cells (Fig. 4 B) show comparable intracellular and membrane fluorescence signal distribution.
|
The studied diffusion is therefore not anomalous, which means that the potential trap energies do not vary over a wide range of time and space. Nevertheless, the diffusion of lipids at the cell membrane is certainly constrained, since the measured diffusion time is
10 times longer than the diffusion time of lipids in an artificial membrane (28This example shows that fitting the ACF obtained with fluorescent lipids diffusing in the plasma membrane does not permit determination of their diffusion mode. On the contrary, measuring the diffusion time at different sizes of the confocal volume is an interesting way of studying the confinement.
Experimental FCS diffusion law
For an experimentalist, it is possible to vary the waist w by changing the extension of the laser beam falling on the microscope objective back-aperture. We name "FCS diffusion law" the plot of the apparent diffusion time
of a membrane component measured by FCS as a function of the square of the waist w2
is defined as the FWHM of the ACF. We will show that this representation is very fruitful to study the constrained submicron diffusion in the cell membrane.
Although the 1-species free 2D diffusion curve seems to fit nicely the experimental ACFs obtained for FL-GM1 and TfR-GFP, the FCS diffusion laws do not reflect free diffusion. Indeed, in both cases the diffusion time is not proportional to the square of the waist w2 as it is expected for free diffusion, where
but is an affine function of w2 (
with t0
0). The intersection of the line with the time axis is strictly positive in the case of FL-GM1 (t0 = 25 ± 3 ms), and strictly negative in the case of TfR-GFP (t0 = 20 ± 2 ms) (Fig. 4 D). Knowing that GM1 is a putative raft marker and that TfR could be sensitive to the cytoskeleton through its cytoplasmic tail, these two different FCS diffusion laws may be signatures for two different diffusion processes.
For diffusive processes, it is expected to have a zero diffusion time at zero beam waist. However, the extrapolation of the experimental diffusion curve to zero beam waist can be nonzero independently of the real value of the diffusion time. In the next core section of this study, we will try to explain the two different intercepts and slopes of the measured diffusion laws with two models for the diffusion of membrane constituents. We will also show that these experimental results (free-like ACFs, but FCS diffusion laws that are not normal) are not paradoxical but can indeed reflect diffusion processes in a submicron structured membrane.
| SIMULATION RESULTS |
|---|
|
|
|---|
Simulated confinement in one impermeable domain
The purpose of this study is to determine how the diffusion behavior of a molecule (as measured by FCS) is sensitive to the presence of impermeable barriers. Moreover, this is useful in determining the minimum size of the simulation area which prevents FCS measurements from boundary effects.
Let us first analyze how ACFs are changed by the confinement of molecules in a single domain with impermeable barriers. We assume a circular domain on the center of which a laser beam is focused. The domain has a radius r and the waist of the laser beam is w. The key parameter is
which reflects the confinement probed by the laser beam. Fig. 5 A shows autocorrelation functions obtained for different values of r and a fixed value of w. The microscopic diffusion coefficient Dmicro is kept the same in all these simulations:
and thus
Fig. 5 A clearly shows that the so-called apparent diffusion time
(FWHM of the ACF) does not generally match the free diffusion time
and depends strongly on the confinement: it decreases when the size of the domain decreases. The decrease of
is a direct consequence of the reduction of the area available for diffusion, which is not defined anymore by the laser beam extension. In the presence of confinement, a diffusion measurement using FCS should not be made at a single value of the waist, since the diffusion law is not that of free diffusion: it leads practically to an overestimation of Dmicro when estimated by
|
with
Three different regimes are observed. For
increases linearly with
as predicted for free diffusion. For intermediate values,
increases more slowly with
and deviates from the standard formula. For
reaches a saturation value. This regime is dominated by a domain size effect: as a further proof, we have verified that the saturation value of
is proportional to
(data not shown).
It has to be noted that these conclusions can be extended to the case of a square domain of side
The confinement probed by the laser beam is then defined by
The proportional coefficient
is chosen so that
is still the ratio of the excitation beam surface area (
) over the confinement area (
). Here again, the free diffusion regime is only obtained when
The shape of the ACF has already been studied in the case of a square domain in Gennerich and Schild (19
).
Simulated confinement in multiple microdomains
In the following, we will distinguish between two hindering processes, and propose a model for both of them. First, we will focus our study on isolated circular microdomains, which try to account for lipid microdomains. Then we will study the diffusion of molecules in a meshwork, which is supposed to model the cytoskeleton.
Isolated microdomains
We have modeled rafts as permeable isolated microdomains surrounded by energy barriers. This model should be able to account for lipid rafts as well as other kinds of domains. We have simulated the diffusion of a molecule in a model membrane where microdomains (phase II) are embedded in a larger square surface of phase I (Fig. 2 A). Microdomains are considered as static entities that are separated from phase I by barriers. They can be either periodically or randomly distributed. We assume that domains are identical disks of radius r distributed over the surface. We make the assumption that the microscopic diffusion coefficients in and out of microdomains, respectively
and
are linked by
as it has been previously measured on artificial membranes (29
).
and
stand for the microscopic diffusion coefficients in liquid-ordered and liquid-disordered phases, respectively. In each simulation, the following parameters are chosen: the microscopic diffusion coefficient outside of the domains is
and the mean jump length is
The size of the radius of the circular domain is r = 100 nm, and the square simulation box A has an area of 100 µm2.
Probabilities of going out of or into a microdomain are Pin and Pout, respectively. If not otherwise stated, these two probabilities have the same value, P. The confinement probed by the laser beam is defined here by
In the following,
is kept constant, so that the confinement strength
is only a function of the probability P.
Shapes of ACFs obtained for different probabilities P of crossing a barrier
Fig. 6 A shows ACFs which have been obtained for different probabilities of crossing the barriers and for w = r, for a laser spot centered on a domain. When P decreases, i.e., when barriers are more impermeable and the confinement strength
increases, the diffusion time increases. Two distinct decay times can be observed for high values of
and small values of
: the short time is related to the diffusion time within a single domain and the longer one is related to the diffusion time through the whole illuminated area. The detection of the first bump is a signature of the presence of a domain that can be on the order of or even smaller (data not shown) than the beam extension (30
).
|
) can be quite nicely fitted by a 1-species 2D free diffusion fit (Fig. 6 B).
We put forward
as an observable of physical meaning that is easy to determine since it does not require the implementation of a complex fit. By varying w, we can explore FCS diffusion laws by observing
It is simply related in the case of free 2D diffusion to the microscopic diffusion coefficient by
In the presence of microdomains, we expect a deviation from this law depending in particular on
and on the size and density of microdomains.
Diffusion laws for fixed size and density of domains and variable probability P of crossing a barrier
To evaluate the different regimes that a FCS experiment can probe, we have determined the variation of the apparent diffusion time with respect to w (having r fixed). We first plot
as a function of
with the laser spot centered on a microdomain, a density of microdomains d = 0.5 and different confinement strengths
(Fig. 7 A). When
i.e., when the diffusion is not free, three regimes can be distinguished. If
particles appear to diffuse freely, and
matches
(regime i): FCS measurements probe the microscopic diffusion coefficient within the microdomain. A transient regime is observed when
: complex diffusion occurs because of barrier effects (regime ii). Last, when
scales linearly with w2 (regime iii). However, it differs significantly from regime i: the intersection with the time axis becomes strictly positive and the line slope increases. The positive intercept as well as the slope are increasing functions of the probability
|
obtained for different positions of the laser spot on the surface of the membrane. Fig. 7 B shows the average value
as an affine function of
The first two regimes, i and ii, cannot be distinguished anymore. When
is a linear function of w2. We find that regime iii is described by the same line as the one obtained when no average is done on the position of the laser waist. In the following, all the diffusion laws will be given with the laser spot centered on one domain. This leads to no change in the description of regime iii, which is the regime we are mostly interested in, since we expect to have w/r > few units in experiments. If the sole regime iii is indeed probed experimentally, an upper limit can be given to the microdomain radius since this regime starts at
We also verified that the same regime iii is obtained for periodically and nonperiodically distributed microdomains as long as there is no percolation (data not shown).
Diffusion laws for a fixed size of domains, a fixed probability P of crossing a barrier and various densities of domains
The same study is carried out for densities ranging from 0.1 to the percolation threshold, with a periodical distribution of microdomains.
Fig. 8 A shows that the intercept and the slope of the line describing regime iii are increasing functions of the density d.
|
The probability of entering a microdomain may not be the same as the probability of exiting the microdomain. To study this case, the diffusion laws have first been drawn for a fixed probability
and a variable value of Pin (Fig. 8 B).
Regime iii are lines, whatever the value of Pin is. The intercepts and the slopes are two increasing functions of Pin. They behave as power laws of Pin.
The diffusion laws have also been drawn for a fixed probability
and a variable value of Pout (Fig. 8 C). In this case, regime iii is still a line, the intercepts and the slopes being decreasing functions of Pout. It can be pointed out that the different simulated diffusion laws obtained for high values of Pout (
) are approximately the same. These high values of Pout lead to a confinement time on the order of the diffusion time in a domain (
). These cases correspond to a low confinement of the molecules in the domain, whereas the probability of entering a domain is low: the diffusion law is very close to the one obtained for impermeable obstacles.
Regime iii of the diffusion laws is a line for densities of microdomains ranging from 0.1 to 0.65, and when
for
(which corresponds to confinement strengths ranging from 1 to 15).
Meshwork
We will now show that the diffusion law is different when the molecule diffusion is hindered by a meshwork instead of isolated microdomains. We consider the case of multiple adjacent domains separated by barriers (Fig. 2 B). This situation may be representative of the diffusion of transmembrane proteins in a cytoskeletal network (e.g., the actin meshwork in COS-7 cells).
For reasons of simplicity, domains are squares separated by straight barriers spaced by a distance of 2r. In each simulation, the following parameters are chosen: the microscopic diffusion coefficient is
the jump length
and the size of the half-side of the squares
The confinement probed by the laser beam is defined here by
with the laser beam centered on a knot of the meshwork.
Fixed size of confinement and variable probability P of crossing the barrier
Fig. 9 A shows ACFs obtained for a fixed illumination laser waist and for different values of
corresponding to different values of P, since
/r is kept constant.
|
(
few units, depending on the confinement strength). Moreover, ACFs obtained for large waists (
few units) are well fitted by a 1-species 2D free-diffusion fit (Fig. 9 B). As in the case of isolated microdomains, study of the shape of the ACF does not give any information on the diffusion mode if the area of the focal spot is more than a few times larger than the area of a single mesh.
Apparent diffusion time when w varies
Fig. 10 A shows
as a function of
for different values of
As expected,
matches
when
For intermediate values of
i.e.,
a short transition regime is observed. When
is a linear function of
: its slope is dependent on
and the intersection with the time axis is negative. The slope and the absolute value of the intersection with the time axis are two increasing functions of the confinement strength
Fig. 10 B shows the average value
as a function of
for
The first two regimes i and ii cannot be distinguished anymore in the case of isolated microdomains. When
is the same linear function of w2 as the one obtained when no average is done on the position of the laser waist.
|
| DISCUSSION |
|---|
|
|
|---|
The determination of the apparent diffusion time
for different values of w permits one to infer the process of diffusion; in particular, we emphasize that
can bring information on the confinement. Fig. 11 summarizes our different results and is presented as a guide for discussion.
|
(regime i)), the diffusion appears to be free: the size of the beam does not permit probing the complexity of the system (either skeletal corrals or isolated microdomains). On the other hand, FCS can then give access to microscopic diffusion coefficients and will be sensitive to heterogeneities: it can be used to determine a two-dimension map of microscopic diffusion coefficients. For laser waists comparable to the size of the domains (
(regime ii)), a transitional diffusion regime is observed. In this regime and for a small probability of crossing the barriers, we expect to detect confinement by a noticeable change of ACFs, which exhibit two different decay times associated respectively to diffusion through the domain and the observation volume (see Figs. 6 A and 9 A). For laser waists larger than the size of the domains (
for isolated domains and
for a meshwork (regime iii)), diffusion is normal again, with an apparent diffusion coefficient
depending on the probability of crossing the barriers, the microscopic diffusion coefficients, and the density of domains (in the case of isolated microdomains). This regime can be approximated by a function of the form
![]() | (5) |
and
are two constants. Interestingly, in simulations, t0 is positive for diffusion in isolated microdomains and negative for corrals.
Phenomenological models for the regime iii of the FCS diffusion law obtained in rafts and corrals
Regime iii is of particular interest since it corresponds to the experimental case when the size of the microdomains is a few times smaller than the diffraction limit. In this section, we focus on the interpretation of parameters
and
(Eq. 5) that are easily deduced from the FCS diffusion laws in this regime.
Diffusion laws in microdomains as a function of the molecular partition inside microdomains
We have shown that the intercept t0 and the slope
of these lines depend on parameters such as the density and the probabilities of entering or exiting microdomains. They also depend on the diffusion coefficients inside and outside microdomains.
Nevertheless, more physical parameters are needed to explain the experimental FCS diffusion laws.
The partition coefficient
of molecules into raft microdomains can be evaluated independently through biochemical studies. The partition coefficient
corresponds to the ratio measured at a given instant of molecules of a certain kind that are inside microdomains over all molecules of this kind. It can also be calculated with our simulations, since the duration of the whole simulated trajectory is much longer than the time needed for the molecule to visit all the allowed points of the state-space (ergodic principle). Hence,
is obtained from the simulated trajectory by calculating the time the molecule spends in microdomains over the whole simulation time.
In the Appendix, we show that the time intercept t0 can be quite well described by a function of
and the confinement time
![]() | (6) |
Since
can be measured from biochemical studies, one can now evaluate the confinement time in a single microdomain
under the usually admitted assumption that
To go further, we give now a possible expression for the slope
of the line describing the regime iii: the total time needed by a molecule to diffuse through the focal spot is the sum of the time it is confined in microdomains and
the time it is not being confined. In this case, one can write
with N the average number of domains that are being crossed.
But as mentioned before, the partition is defined (in the time description) by the time a molecule spends in microdomains over the total diffusion time, which can be written as
This leads to
which is equivalent to
in terms of diffusion coefficients.
If molecules enter easily in microdomains, which is the case if the partition is
>0.5, Dfree is equal to Dout. If molecules do not enter easily in microdomains, which is the case if the partition is
<0.5, they diffuse among microdomains as if they were impermeable obstacles and Dfree is equal to Dobst, which is the effective diffusion coefficient among impermeable obstacles. An expression of Dobst in terms of the surface density covered by the obstacles is given in the Appendix.
As a consequence, this leads to the following expression for the effective diffusion coefficient in the presence of permeable microdomains:
![]() | (7) |
Diffusion laws in a meshwork as a function of the confinement strength
In all diffusion simulations in a meshwork, the particle visits a certain number of meshes during its diffusion in the confocal volume. The average number N of meshes that are crossed is only a function of the waist of the focal spot, not of the probability of passing a barrier. The mean diffusion time through the focal spot is equal to the number of crossed meshes multiplied by the confinement time in a single mesh so that
In the case of free diffusion, the diffusion time in the focal spot is given by the number of crossed meshes multiplied by the diffusion time in a single mesh:
As a consequence, the asymptotic diffusion law needs to be a line with a slope equal to
For spatial scales much smaller than the mesh size, one expects to obtain a free diffusion law, i.e., a line with a slope equal to
Finally, the spatial scale at which regime ii and regime iii cross should be close to the mesh size. It can be seen from the simulated FCS diffusion laws that the crossover is found for
The actual FCS diffusion law can be calculated from the slopes derived from this intuitive model, and the crossover obtained from the simulations; we find
![]() | (8),(9) |
These equations fit quite nicely the FCS diffusion laws obtained from the simulations (data not shown). Note that the determination of the crossover point provides a measure of the mesh size.
Interpretation of the experimental results
Diffusion modes encountered in COS-7 cells
To end up our discussion, we now come back on the experimental results that have been presented in Fig. 4. In the framework of our model, the diffusion modes of both the FL-GM1 and the TfR-GFP can now be inferred from the shapes of the measured FCS diffusion laws. For FL-GM1, the large waists diffusion law (regime iii) can be fitted by a line with a positive intercept. This diffusion law is well described by the microdomain model. This can be related to the fact that FL-GM1 is a putative raft marker, which means that biochemical studies show that it partitions into rafts.
For TfR-GFP, the large waists diffusion law (regime iii) is a line with a negative intercept, which is compatible with a diffusion hindered by the cytoskeleton meshwork.
Confinement time values
Through biochemical studies, it has be shown that 40% of GM1 partition into detergent resistant membranes (35
,36
), whereas its fluorescent analog FL-GM1 is expected to have a much smaller partition coefficient (37
). Thus, a lower limit of the confinement time into microdomains can be inferred from the partition
and the intercept
An upper limit can be given to the microdomain radius, because the sole affine regime (iii) is observed experimentally. Since this regime corresponds to
and the experimental waist is >200 nm (diffraction-limited), the maximum value for the microdomain radius should be
60 nm. Moreover, at a waist of 200 nm, we measured a diffusion time of 30 ms. Thus, the diffusion time through a domain would be at most 3 ms. The time intercept being much larger than this time, we can conclude that
conf >>
diff and
ms.
The confinement time in a mesh of the cytoskeleton can also be calculated from the negative time intercept of TfR-GFP diffusion law, since
ms.
As mentioned before, these two diffusion examples are representative of some more experimental results that will be presented in detail in Lenne et al. (unpublished).
| CONCLUSION |
|---|
|
|
|---|
From a biological point of view, this will unravel the relationship between molecular confinement and biological functions such as signaling processes. From a physical point of view, this offers a new tool to study the transition from anomalous to normal diffusion (38
).
| APPENDIX: EFFECTIVE DIFFUSION COEFFICIENT AND TIME INTERCEPT FOR THE MICRODOMAIN MODEL |
|---|
|
|
|---|
![]() |
(data not shown). To confront our heuristic model with the simulation results, we compare the calculated time intercept and slope given by Eqs. 6 and 7 with those obtained from our simulations. Fig. 12 shows that both the time intercept and the effective diffusion coefficient are very well described by Eqs. 6 and 7.
|
| ACKNOWLEDGEMENTS |
|---|
|
|
|---|
This work was supported by institutional grants from the Centre National de la Recherche Scientifique and Institut National de la Santé et de la Recherche Médicale, and by specific grants from the Fondation pour la Recherche Médicale, Ministère de l'Education Nationale, de l'Enseignement Supérieur et de la Recherche, and Centre National de la Recherche Scientifique. L.W. is recipient of a doctoral fellowship from the Ministère de l'Education Nationale, de l'Enseignement Supérieur et de la Recherche.
| FOOTNOTES |
|---|
Submitted on June 3, 2005; accepted for publication August 30, 2005.