help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on November 18, 2005.
doi:10.1529/biophysj.105.075176
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
biophysj.105.075176v1
90/2/L17    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Destainville, N.
Right arrow Articles by Salomé, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Destainville, N.
Right arrow Articles by Salomé, L.
Biophysical Journal 90:L17-L19 (2006)
© 2006 The Biophysical Society

Quantification and Correction of Systematic Errors Due to Detector Time-Averaging in Single-Molecule Tracking Experiments

Nicolas Destainville * and Laurence Salomé {dagger}

* Laboratoire de Physique Théorique, UMR CNRS-UPS 5152, Université Paul Sabatier, 31062 Toulouse, France; and {dagger} Institut de Pharmacologie et de Biologie Structurale, UMR CNRS-UPS 5089, 31077 Toulouse, France

Correspondence: Address reprint requests and inquiries to Laurence Salomé, E-mail: laurence.salome{at}ipbs.fr.


    ABSTRACT
 TOP
 ABSTRACT
 REFERENCES
 
Single-molecule tracking is a powerful way to look at the dynamic organization of plasma membranes. However, there are some limitations to its use. For example, it was recently observed, using numerical simulation, that time-averaging effects inherent to the exposure time of detectors are likely to bias the apparent motion of molecules confined in microdomains. Here, we solve this apparently limiting issue analytically. We explore this phenomenon by calculating its effects on the observed diffusion coefficients and domain sizes. We demonstrate that the real parameters can be easily recovered from the measured apparent ones. Interestingly, we find that single-molecule tracking can be used to explore events occurring at a timescale smaller than the exposure time.

It has been pointed out (1Go) that time-averaging, due to the exposure time of detectors in single-molecule tracking experiments, can have dramatic effects. This is particularly important in measures of the apparent motion of tracked molecules (proteins or lipids) at the cell surface when they are confined in small regions of the membrane, such as rafts, synapses, or other signaling platforms. Diffusion coefficients and size of confining domains can be significantly underestimated. However, the arguments used relied on numerical simulation (1Go) and it seems important to validate them by analytical calculation. The work presented here addresses this issue and also enables the prediction of the range of experimental parameters within which this detector time-averaging effect perturbs the observations. Using systematic quantification of the time-averaging effects in the ranges of parameters of experimental relevance, we demonstrate that the values of diffusion coefficients or domain sizes are not significantly affected in a broad range of parameters. In addition, we show that these effects can be easily corrected and that real parameters can be recovered from those measured using simple formulas.

Consider a molecule diffusing in the membrane with diffusion coefficient D. Its displacements are followed by single-molecule tracking by means of a detector with exposure time T. Rm(t) denotes the measured position of the molecule at time t (multiple of T). The measured mean-square deviation MSDm(t) is

(1)
where the brackets denote a discrete average over frames s. We further suppose that the diffusion is restricted to a square domain of side L. The usual experimental procedure to extract information from MSDm(t) is to fit it with the expected generic expression for a confined diffusion:

(2)
from which one extracts the measured (or apparent) domain size Lm and equilibriation time {tau}m. The measured diffusion coefficient Dm is given by

The real time-dependent positions of the molecule (as opposed to those measured) are denoted by r(t). Because the molecule is confined, they are correlated. The real equilibriation time {tau} in the box is the typical decay time of the following two-time correlator C(t) where averages are over times s:

(3)

In practice, there are several timescales because the different modes of the diffusion operator do not decay at the same rate in the square box (2Go). The slowest mode decays exponentially with a decay time {tau}0 = L2 / ({pi}2D) and the next modes have decay times {tau}0/(2k + 1)2 with k an integer. Keeping the first-order term in the exact expansion of C(t) (2Go)

(4)
leads to the approximation

(5)
as C(0), the variance of r(t), equals L2/6. To restore the fact that C(t) C(0) =1/2 <(r(s + t) – r(s))2> = 2 D t at small t for a diffusing molecule, we need to set

(6)

Note that Eqs. 5 and 6 remain valid if the confining domain is not a square, but a disk, an ellipse or any more complex shape. In such cases, {tau} still represents the equilibriation time and L is the typical domain size. For example, if the domain is a circle, its diameter is related to L by d = (2/{surd}3) L. For a quadratic confining potential, U(r) = 1/2Kr2, Eq. 5 is even exact (3Go) and L is the typical width of the trap at temperature {theta} given by L2 = 6kB{theta}/K.

The measured position Rm(t) is related to the real one by

(7)

After replacing Rm(t) using Eq. 7, the expansion of Eq. 1 leads to four correlators. Approximating them with Eq. 5 and setting x = {tau} / T gives

(8)

This exact expression of the measured MSDm(t) in the case of a detector time-averaging is valid only if t ≥ T. If t < T, MSDm(t) is still calculable but this is beyond the scope of this letter.

We extract the measured parameters from MSDm(t) as described above and compare them to the real ones. The domain size Lm is obtained by equaling the large t limits of Eqs. 8 and 2:

(9)

From Eq. 2, we get {tau}m via the simple relation

(10)

We have checked that within the range of parameters studied here, the so-obtained value of {tau}m is the same as the one deduced from the fit of MSDm(t) by Eq. 2. If we set f(x) = x2 (exp(1/x) + exp(–1/x) – 2), Eqs. 10 and 8 give

(11)

When x is large, or {tau} >> T, the previous equation reads at the first order in 1/x. We have checked that this approximation remains excellent as long as x ≥ 1/3. For any x < 1/3, as for instance in the case of a very large diffusion coefficient D (see, for example, Ritchie et al. (1Go)), we have checked by numerical simulation that {tau}m < 2T/3. Thus, any measured {tau}m ≥ 2T/3 ensures that x ≥ 1/3 and that the real corrected {tau} ≥ T/3 is given by

(12)
which is of immediate practical interest to extract equilibriation times from measured ones. The real L is then calculated using Eq. 9, which reads

(13)
and the real D can now be recovered from Eq. 6. The corrected parameters are thus simply determined using Eqs. 13 and 6. In the case of an exposure (or averaging) time T smaller than the time T' between two successive frames, the calculation leading to Eq. 8 is unchanged as well as its consequences. In particular, Eqs. 12 and 13 still hold. If the confinement geometry is more complex than a square, the whole analysis, based on the correlator in Eq. 5 itself independent of geometry, remains valid. The only difference is that L does then not measure the side of a square but a typical domain size.

To summarize, we have quantified how time-averaging affects observables of biological interest. However, if {tau} is large compared to the exposure time T, then {tau}, L, and D remain essentially unmodified. This point is illustrated in both Table 1 and in the following example.


View this table:
[in this window]
[in a new window]
 
TABLE 1  Comparison of apparent analytically and numerically calculated L and D, and corrected ones, to their real values for different temporal regimes

 
The cases of domain-to-domain jumps or other mechanisms leading to slow long-term diffusion (with coefficient DMAC) superimposed to confined short-term diffusion (4Go) deserve attention (1Go). We consider, as an example, the movement of the µ-opioid receptor at the surface of a normal rat kidney fibroblast cell from Daumas et al. (5Go). We calculate MSDm(t) from one trajectory acquired at common video rate, i.e., T = 40 ms (see Fig. 1).



View larger version (81K):
[in this window]
[in a new window]
 
FIGURE 1  Experimental trajectory (120 s) of a µ-opioid receptor at the surface of a normal rat kidney cell (5Go), truncated in successive 20-s segments shown in different colors (indigo, cyan, green, yellow, orange, red) to highlight the displacement of the confining domain of size L {cong} 500 nm, in which the receptor diffuses rapidly. The black trajectory shows the slow diffusion of the barycenter of this domain calculated on sliding 4-s intervals.

 
Fitting this MSDm(t) with the generic form:

(14)
we find {tau}m = 192 ms and Lm = 483 nm. We deduce {tau} = 178 ms (from Eq. 12), L = 501 nm (from Eq. 13), and finally D = 0.117 µm2s–1 whereas Dm = 0.101 µm2s–1 (from Eq. 6). The influence of time-averaging is weak in this case, as well as in all the trajectories of Daumas et al. (5Go), because T << {tau}m. This validates a posteriori the measures in Daumas et al. (5Go). By contrast if {tau}m is smaller than a few T, the corrections to {tau} and L must imperatively be taken into account. In addition to the existing numerical data from Ritchie et al. (1Go), we have performed numerical simulations in all relevant ranges of the parameters ({tau} ≥ T/3). The agreement with our analytical predictions is excellent (see Table 1). Our formulas allow us to recover accurately the real L and D from those measured within a few percents.

To conclude, we have demonstrated that the drawbacks of single-molecule tracking techniques due to time-averaging are limited. In the case of confined diffusion in membrane domains, we have proposed simple formulas to recover the real domain sizes and diffusion coefficients from those measured. The accuracy remains excellent for confinements with characteristic diffusion times down to {tau} = T/3 where T is the exposure time, i.e., {tau} is of the order of 10 ms at common video rates. Interestingly, this work has shown that events occurring at a timescale smaller than the exposure time can be explored by single-molecule tracking.

Submitted on September 28, 2005; accepted for publication November 7, 2005.


    REFERENCES
 TOP
 ABSTRACT
 REFERENCES
 
1. Ritchie, K., X.-Y. Shan, J. Kondo, K. Iwasawa, T. Fujiwara, and A. Kusumi. 2005. Detection of non-Brownian diffusion in the cell membrane in single molecule tracking. Biophys. J. 88:2266–2277.[Abstract/Free Full Text]

2. Logan, J. D. 2004. Applied Partial Differential Equations. Springer, Berlin, Germany.

3. Doi, M., and S. F. Edwards. 1986. The Theory of Polymer Dynamics. Oxford University Press, Oxford, UK.

4. Powles, J. G., M. J. D. Mallett, G. Rickayzen, and W. A. B. Evans. 1992. Exact analytic solutions for diffusion impeded by an infinite array of partially permeable barriers. Proc. R. Soc. Lond. A. 436:391–403.

5. Daumas, F., N. Destainville, C. Millot, A. Lopez, D. Dean, and L. Salomé. 2003. Confined diffusion without fences of a G-protein-coupled receptor as revealed by single particle tracking. Biophys. J. 84:356–366.[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
Biophys. JHome page
N. Destainville, A. Sauliere, and L. Salome
Comment to the Article by Michael J. Saxton: A Biological Interpretation of Transient Anomalous Subdiffusion. I. Qualitative Model
Biophys. J., October 1, 2008; 95(7): 3117 - 3119.
[Full Text] [PDF]


Home page
Am. J. Physiol. Cell Physiol.Home page
V. Nechyporuk-Zloy, P. Dieterich, H. Oberleithner, C. Stock, and A. Schwab
Dynamics of single potassium channel proteins in the plasma membrane of migrating cells
Am J Physiol Cell Physiol, April 1, 2008; 294(4): C1096 - C1102.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
S. Wieser, M. Moertelmaier, E. Fuertbauer, H. Stockinger, and G. J. Schutz
(Un)Confined Diffusion of CD59 in the Plasma Membrane Determined by High-Resolution Single Molecule Microscopy
Biophys. J., May 15, 2007; 92(10): 3719 - 3728.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
S. Semrau and T. Schmidt
Particle Image Correlation Spectroscopy (PICS): Retrieving Nanometer-Scale Correlations from High-Density Single-Molecule Position Data
Biophys. J., January 15, 2007; 92(2): 613 - 621.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
biophysj.105.075176v1
90/2/L17    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Destainville, N.
Right arrow Articles by Salomé, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Destainville, N.
Right arrow Articles by Salomé, L.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Biophysical Society.