help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Originally published as Biophys J. BioFAST on September 8, 2006.
doi:10.1529/biophysj.106.089524
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
biophysj.106.089524v1
91/11/4253    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rickgauer, J. P.
Right arrow Articles by Smith, D. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rickgauer, J. P.
Right arrow Articles by Smith, D. E.
Biophysical Journal 91:4253-4257 (2006)
© 2006 The Biophysical Society

DNA as a Metrology Standard for Length and Force Measurements with Optical Tweezers

John Peter Rickgauer, Derek N. Fuller and Douglas E. Smith

Department of Physics, University of California, San Diego, La Jolla, California

Correspondence: Address reprint requests to D. E. Smith, E-mail: des{at}physics.ucsd.edu.


    ABSTRACT
 TOP
 ABSTRACT
 INTRODUCTION
 APPROACH
 EXPERIMENTAL METHODS
 RESULTS AND DISCUSSION
 ACKNOWLEDGEMENTS
 REFERENCES
 
Optical tweezers have broad applications in studies of structures and processes in molecular and cellular biophysics. Use of optical tweezers for quantitative molecular-scale measurement requires careful calibration in physical units. Here we show that DNA molecules may be used as metrology standards for force and length measurements. Analysis of DNA molecules of two specific lengths allows simultaneous determination of all essential measurement parameters. We validate this biological-calibration method experimentally and with simulated data, and show that precisions in determining length scale factor (~0.2%), length offset (~0.03%), force scale factor (~2%), and compliance of the traps (~3%) are limited only by current measurement variation, much of which arises from polydispersity of the microspheres (~2%). We find this procedure to be simpler and more convenient than previous methods, and suggest that it provides an easily replicated standard that can insure uniformity of measurements made in different laboratories.


    INTRODUCTION
 TOP
 ABSTRACT
 INTRODUCTION
 APPROACH
 EXPERIMENTAL METHODS
 RESULTS AND DISCUSSION
 ACKNOWLEDGEMENTS
 REFERENCES
 
The optical tweezers method, pioneered by Ashkin and co-workers, has been applied widely in biophysics research, enabling manipulation of prokaryotic and eukaryotic cells, cellular organelles, viruses, DNA, RNA, and protein molecules, and molecular motor complexes (1Go–9Go). This method allows imposition and measurement of nanometer-level displacements and picoNewton-level forces on the molecular scale. Calibration of these measurements in physical units requires accurate determination of multiple measurement parameters, and although it is possible to calculate certain parameters from physical principles in some cases (10Go), calibration is generally necessary. Here, we describe a simple and convenient method whereby a pair of DNA molecules may be used as reference standards for determination of all necessary measurement parameters. This approach is made possible by the fact that DNA is a linear polymer whose chemical structure is known with atomic accuracy and whose elastic force properties have been well characterized (11Go–14Go).

Conventional calibration methods usually involve multiple steps, including optical magnification calibration, microsphere centroid tracking, application of calibrated hydrodynamic flows, and statistical analysis of Brownian fluctuations (10Go,15Go,16Go). Although these methods are well established, none offers the convenience and precision of a universal reference standard that can be replicated by any lab. We apply this concept to metrology of optical tweezers, but note that it should also be applicable to atomic force microscopes, microneedles, and magnetic tweezers (11Go,17Go,18Go).


    APPROACH
 TOP
 ABSTRACT
 INTRODUCTION
 APPROACH
 EXPERIMENTAL METHODS
 RESULTS AND DISCUSSION
 ACKNOWLEDGEMENTS
 REFERENCES
 
As illustrated in Fig. 1, an optically trapped microsphere subject to an external force F is displaced from its equilibrium position by a distance

Formula 1(1)
where {gamma} is the trap compliance, usually expressed in nm/pN (19Go). This induces deflection of the exiting laser beam, which can be measured by a position-sensing photodetector (PSD), such that the force is proportional to the measured signal by

Formula 2(2)
where V is a measured voltage, V0 is a voltage offset, and {alpha} is a force scale factor, usually expressed in pN/volt (19Go). In practice, V0 can accurately be set to zero by measuring the detector signal under conditions with no applied force (i.e., in the absence of tethered DNA).


Figure 1
View larger version (12K):
[in this window]
[in a new window]
 
FIGURE 1  Experimental geometry. The distance between the two optical traps is d, the end-to-end extension of the tethered DNA is x, the radii of the trapped microspheres are r1 and r2, the force on the microspheres is F, and the displacements of the microspheres from the trap centers are {Delta}x1 and {Delta}x2.

 
In our dual-trap system, the trap separation d is controlled using an acousto-optic deflector (AOD), creating a displacement proportional to the AOD drive frequency,

Formula 3(3)
where ß is a scale factor, usually expressed in nm/MHz. Length measurements are thus defined by

Formula 4(4)
where fB is the AOD drive frequency at which the two microspheres (of radii r1 and r2) come into contact at F = 0; in this way, the parameter fB specifies a length offset. Analogous parameters exist for single-trap systems that use a nanopositioning stage to generate displacements if the DNA is tethered by one end to the substrate (13Go), such that our method is also applicable in this case.

Complete calibration of such a system involves determination of {alpha}, ß, {gamma}, and fB. Our approach takes advantage of the fact that the elastic behavior of double-stranded DNA is very well described by the worm-like chain (WLC) model (6Go,20Go–22Go). In this model, the molecular contour length per basepair, Lbp, persistence length, P, and stretch modulus, S, are physical parameters that characterize the mechanical elasticity of DNA. In this study we employ a set of high-resolution values reported in Wang et al. (13Go), where P = 47.4 ± 1.0 nm, S = 1008 ± 38 pN, and Lbp = 0.342 ± 0.001 nm for double-stranded DNA. We use Odijk's analytical approximation for WLC elasticity,

Formula 5(5)
where x is the end-to-end extension of the molecule, L is the contour length of the molecule, and kT is the thermal energy (~4.14 pN-nm at room temperature) (21Go). We verified that this approximation agrees with the exact numerical solution (14Go) to within 0.1% over the range of forces being applied (4–40 pN).

When a single DNA molecule is stretched between two optically trapped microspheres, the imposed end-to-end extension is given by

Formula 6(6)
where {Delta}x = {Delta}x1 + {Delta}x2, and {gamma} = {gamma}1 + {gamma}2 is the series compliance of the two optical traps (Fig. 1). By combining Eqs. 2, 5, and 6 we arrive at the following expression for DNA elasticity in instrument units of AOD frequency and PSD voltage,

Formula 7(7)
where we have introduced the constants,

Formula 8(8)

Formula 9(9)

Formula 10(10)

Formula 11(11)

Formula 12(12)

Examination of Eqs. 710 indicates that the complete set of parameters ({alpha}, ß, {gamma}, and fB) may be determined by measuring voltage (V) versus frequency (f) for two DNA molecules of different lengths, L1 and L2. The constants Ai, Bi, and Ci (for i = 1,2) may be determined by fitting these two data sets to Eq. 7. Solving the system of Eqs. 810 then yields the following expressions for the measurement parameters:

Formula 13(13)

Formula 14(14)

Formula 15(15)

Formula 16(16)

We note that if ß is determined independently, for example by use of a stage micrometer and video tracking of the microsphere centroid, one may calibrate the other three parameters by stretching only one length of DNA and then using Eqs. 1416. We find it easier and sufficiently accurate to calibrate all four parameters by the single method of stretching DNA.


    EXPERIMENTAL METHODS
 TOP
 ABSTRACT
 INTRODUCTION
 APPROACH
 EXPERIMENTAL METHODS
 RESULTS AND DISCUSSION
 ACKNOWLEDGEMENTS
 REFERENCES
 
We have demonstrated this approach using a dual-optical tweezers system built in our laboratory. In brief, our apparatus consists of a diode-pumped solid-state Nd:YAG laser (CrystaLaser, Reno, NV) split into two orthogonally polarized beams that are focused by a water-immersion microscope objective (Plan Apochromat, 1.2 NA, Olympus America, Melville, NY) to form two optical traps. One beam is steered precisely by use of an acousto-optic deflector (IntraAction, Bellwood, IL) while the other beam is fixed. The exiting beams are collected by a second objective, and the deflections of the fixed beam are measured by reimaging the back focal plane of this objective onto the face of a position-sensing detector (On-Trak Photonics, Lake Forest, CA). We verified that the response is linear (i.e., satisfies Eq. 2) up to ~50 pN (Table 1), which covers the entire range used for calibration (4–40 pN). Linearity in this regime has been reported previously for a similar instrument configuration (19Go). We note that methods have also been developed to detect forces in the axial direction (23Go–26Go), and although our system is not configured for this mode of measurement, we suspect that our method of calibration would provide a simple alternative in this case.


View this table:
[in this window]
[in a new window]
 
TABLE 1  Measurement parameters determined from the experimental data in Fig. 2

 

Figure 2
View larger version (16K):
[in this window]
[in a new window]
 
FIGURE 2  Averaged experimental datasets recorded for DNA molecules of the indicated lengths (points) and fits to Eq. 7 (solid lines, overlaid). Deviations from the fits are shown in the two lower plots. The fits were used to determine the measurement parameters listed in Table 1.

 
The DNA molecules used in this study were produced by PCR using biotin- and digoxigenin-labeled primers and tethered between streptavidin and anti-digoxigenin coated microspheres (2.2-µm and 2.1-µm diameters; Spherotech, Libertyville, IL), as described previously (27Go). Due to the method of attachment via specific labels at each end, only intact, full-length molecules can normally be tethered. These molecules are AT-GC balanced (~48–49% GC) and previous measurements indicate that the elasticity of such molecules typically only varies by a small amount (<2%) (27Go), justifying our use of the values for P, S, and Lbp reported in Wang et al. (13Go).

High-resolution measurements were made by changing the AOD drive frequency in 500 Hz steps and digitizing the PSD signal. Measurements were performed on 12 different 25-kbp molecules and nine different 40-kbp molecules. Multiple measurements were done to obtain averaged datasets because each molecule was tethered between a different pair of microspheres (standard deviation in radii of 2%). We note that the calibration method includes these variations and results in determination of parameters for the average microsphere. Datasets were boxcar-averaged in 10-kHz intervals and fit to Eq. 7 using the Levenberg-Marquardt least-squares algorithm (28Go). Precisions in determining the measurement parameters were quantified using the bootstrap method (29Go) to calculate the standard error, generating 100 bootstrapped datasets from each of the original 12 and nine datasets and calculating standard deviations of parameters yielded by fitting the 10,000 resultant pairings. All measurements were performed at 20.7 ± 0.5°C in a solution containing 10 mM Tris-HCl (pH 7.4), 1 mM EDTA, 100 mM NaCl, and 0.1 mg/ml BSA.


    RESULTS AND DISCUSSION
 TOP
 ABSTRACT
 INTRODUCTION
 APPROACH
 EXPERIMENTAL METHODS
 RESULTS AND DISCUSSION
 ACKNOWLEDGEMENTS
 REFERENCES
 
Two DNA constructs, of lengths 25,340 and 40,368 basepairs, were used as molecular reference standards and measured with a dual-optical tweezers apparatus, yielding data sets in uncalibrated instrument units of PSD voltage versus AOD drive frequency. All of the necessary measurement parameters were then obtained by fitting these data to the derived expression (Eq. 7). As shown in Fig. 2, the fits were excellent, and all four of the measurement parameters were precisely determined (Table 1). Standard errors in the length scale factor and length offset were only 0.15% and 0.03%, respectively, while the largest error (in determining compliance) was only 3.3%. A procedure for reducing this error further was also developed, as described below. The parameters determined by this method were consistent with independent estimates obtained using conventional calibration methods (Table 1).

We further validated our technique by using simulated data (Table 2). Datasets were generated using the WLC model for the mean parameters reported in Table 1. Normally distributed noise with a standard deviation similar to that observed in the experimental measurements was added and reported uncertainties in DNA elasticity were assumed. An ensemble of such simulated datasets was then analyzed in the same manner as the experimental data. As seen in Table 2, precisions obtained with experimentally observed noise levels were in good agreement with those determined experimentally. Variations in microsphere size (standard deviation of 2%; Spherotech) account for the majority of the deviation through their effect on length offset and trap compliance (30Go). An ensemble of ~60 force-extension measurements with different bead pairs confirmed this level of variation, and fits to simulated datasets showed that this variation (2.6%) could explain most of the small uncertainty in the determination of the compliance.


View this table:
[in this window]
[in a new window]
 
TABLE 2  Dependence of the measurement parameters on measurement noise and uncertainty in the DNA parameters

 
The very high precision in determining ß and fB derives from the fact that L1, L2, and f are known with high certainty. We also found by using simulated datasets that the precision in determining {gamma} could be refined by fixing the three other measurement parameters (which could be determined more accurately) and performing a one-parameter fit to additional datasets (Table 2) or, better yet, by use of special, high uniformity microspheres (such as are available from NIST). The accuracy is limited minimally by present uncertainties in the DNA parameters. Further reductions in uncertainties of these parameters are expected as an outcome of advances in instrumentation (31Go).

DNA as a molecular metrology standard
Scientific measurements must ultimately be defined by comparison to standards, which is a primary concern of the field known as metrology (32Go). With growing interest in the study of nanoscale structures in the physical and biological sciences comes an increasing need for precise, accurate, and readily applicable standards that will insure uniformity of measurements across different laboratories.

The proposed use of DNA as a metrology standard holds interesting conceptual advantages. Its advantage as a nanoscale standard comes from its intrinsic "sameness": a given DNA sequence has specific physical properties that are exactly the same from molecule to molecule. Furthermore, its length can be precisely controlled in incremental units of a single basepair (~0.34 nm). Specific DNA molecules can also be replicated exactly in any laboratory by use of standard techniques in molecular biology (33Go).

It is important to note that the physical properties of DNA vary with temperature and solution conditions (34Go), so these conditions need to be controlled to obtain highly accurate results. An investigation of the ultimate limits of precision with which DNA could be employed as a standard is beyond the scope of our current study. Rather, we have demonstrated as a proof of principle a method by which DNA may be used as a physical standard for calibrating length and force measurements. Our method permitted us to determine all four necessary instrument calibration parameters with sufficient precision for most applications in biophysics and in a manner that required only a single type of measurement.


    ACKNOWLEDGEMENTS
 TOP
 ABSTRACT
 INTRODUCTION
 APPROACH
 EXPERIMENTAL METHODS
 RESULTS AND DISCUSSION
 ACKNOWLEDGEMENTS
 REFERENCES
 
We thank A. Schweitzer for helpful comments.

This work was supported by the Arnold and Mabel Beckman Foundation, the Kinship Foundation, and the National Institutes of Health.

Submitted on May 18, 2006; accepted for publication August 24, 2006.


    REFERENCES
 TOP
 ABSTRACT
 INTRODUCTION
 APPROACH
 EXPERIMENTAL METHODS
 RESULTS AND DISCUSSION
 ACKNOWLEDGEMENTS
 REFERENCES
 
1. Ashkin, A., J. M. Dziedzic, J. E. Bjorkholm, and S. Chu. 1986. Observation of a single-beam gradient force optical trap for dielectric particles. Opt. Lett. 11:288–290.

2. Ashkin, A., and J. M. Dziedzic. 1987. Optical trapping and manipulation of viruses and bacteria. Science. 235:1517–1520.[Abstract/Free Full Text]

3. Ashkin, A., J. M. Dziedzic, and T. Yamane. 1987. Optical trapping and manipulation of single cells using infrared-laser beams. Nature. 330:769–771.[CrossRef][Medline]

4. Ashkin, A., K. Schutze, J. M. Dziedzic, U. Euteneuer, and M. Schliwa. 1990. Force generation of organelle transport measured in-vivo by an infrared-laser trap. Nature. 348:346–348.[CrossRef][Medline]

5. Mehta, A. D., M. Rief, J. A. Spudich, D. A. Smith, and R. M. Simmons. 1999. Single-molecule biomechanics with optical methods. Science. 283:1689–1695.[Abstract/Free Full Text]

6. Bustamante, C., S. B. Smith, J. Liphardt, and D. Smith. 2000. Single-molecule studies of DNA mechanics. Curr. Opin. Struct. Biol. 10:279–285.[CrossRef][Medline]

7. Liphardt, J., B. Onoa, S. B. Smith, I. J. Tinoco, and C. Bustamante. 2001. Reversible unfolding of single RNA molecules by mechanical force. Science. 292:733–737.[Abstract/Free Full Text]

8. Lang, M. J., and S. M. Block. 2003. Resource letter. LBOT-1: laser-based optical tweezers. Am. J. Phys. 71:201–215.[Medline]

9. Cecconi, C., E. A. Shank, C. Bustamante, and S. Marqusee. 2005. Direct observation of the three-state folding of a single protein molecule. Science. 309:2057–2060.[Abstract/Free Full Text]

10. Smith, S. B., Y. Cui, and C. Bustamante. 2003. Optical-trap force transducer that operates by direct measurement of light momentum. Methods Enzymol. 361:134–162.[Medline]

11. Smith, S. B., L. Finzi, and C. Bustamante. 1992. Direct mechanical measurements of the elasticity of single DNA molecules by using magnetic beads. Science. 258:1122–1126.[Abstract/Free Full Text]

12. Smith, S. B., Y. Cui, and C. Bustamante. 1996. Overstretching B-DNA: the elastic response of individual double-stranded and single-stranded DNA molecules. Science. 271:795–799.[Abstract]

13. Wang, M. D., H. Yin, R. Landick, J. Gelles, and S. M. Block. 1997. Stretching DNA with optical tweezers. Biophys. J. 72:1335–1346.[Abstract/Free Full Text]

14. Bouchiat, C., M. D. Wang, J. Allemand, T. Strick, S. M. Block, and V. Croquette. 1999. Estimating the persistence length of a worm-like chain molecule from force-extension measurements. Biophys. J. 76:409–413.[Abstract/Free Full Text]

15. Svoboda, K., and S. M. Block. 1994. Biological applications of optical forces. Annu. Rev. Biophys. Biomol. Struct. 23:247–285.[Medline]

16. Simmons, R. M., J. T. Finer, S. Chu, and J. A. Spudich. 1996. Quantitative measurements of force and displacement using an optical trap. Biophys. J. 70:1813–1822.[Abstract/Free Full Text]

17. Ishijima, A., H. Kojima, H. Higuchi, Y. Harada, T. Funatsu, and T. Yanagida. 1996. Multiple- and single-molecule analysis of the actomyosin motor by nanometer-picoNewton manipulation with a microneedle: unitary steps and forces. Biophys. J. 70:383–400.[Abstract/Free Full Text]

18. Rief, M., M. Gautel, F. Oesterhelt, J. M. Fernandez, and H. E. Gaub. 1997. Reversible unfolding of individual titin immunoglobulin domains by AFM. Science. 276:1109–1112.[Abstract/Free Full Text]

19. Wuite, G. J., R. J. Davenport, A. Rappaport, and C. Bustamante. 2000. An integrated laser trap/flow control video microscope for the study of single biomolecules. Biophys. J. 79:1155–1167.[Abstract/Free Full Text]

20. Kratky, O., and G. Porod. 1949. X-ray studies of string-like molecules in solution. Rec. Trav. Chim. Pays-Bas. 68:1106–1123.

21. Odijk, T. 1995. Stiff chains and filaments under tension. Macromolecules. 28:7016–7018.[CrossRef]

22. Marko, J. F., and E. D. Siggia. 1995. Stretching DNA. Macromolecules. 28:8759–8770.[CrossRef]

23. Ghislain, L. P., N. A. Switz, and W. W. Webb. 1994. Measurement of small forces using an optical trap. Rev. Scientif. Instr. 65:2762–2768.[CrossRef]

24. Pralle, A., M. Prummer, E. L. Florin, E. H. K. Stelzer, and J. K. H. Horber. 1999. Three-dimensional high-resolution particle tracking for optical tweezers by forward scattered light. Microsc. Res. Tech. 44:378–386.[CrossRef][Medline]

25. Kress, H., E. H. K. Stelzer, G. Griffiths, and A. Rohrbach. 2005. Control of relative radiation pressure in optical traps: application to phagocytic membrane binding studies. Phys. Rev. E. 71:061927.[CrossRef]

26. Deufel, C., and M. D. Wang. 2006. Detection of forces and displacements along the axial direction in an optical trap. Biophys. J. 90:657–667.[Abstract/Free Full Text]

27. Fuller, D. N., G. J. Gemmen, J. P. Rickgauer, A. Dupont, R. Millin, P. Recouvreux, and D. E. Smith. 2006. A general method for manipulating DNA sequences from any organism with optical tweezers. Nucleic Acids Res. 34:e15.[Abstract/Free Full Text]

28. Coleman, T., M. Branch, and A. Grace. 1999. Optimization Toolbox for Use with MatLab. The MathWorks, Natick, MA.

29. Efron, B., and R. Tibshirani. 1991. Statistical-data analysis in the computer age. Science. 253:390–395.[Abstract/Free Full Text]

30. Ashkin, A. 1992. Forces of a single-beam gradient laser trap on a dielectric sphere in the ray optics regime. Biophys. J. 61:569–582.[Abstract/Free Full Text]

31. Abbondanzieri, E. A., W. J. Greenleaf, J. W. Shaevitz, R. Landick, and S. M. Block. 2005. Direct observation of base-pair stepping by RNA polymerase. Nature. 438:460–465.[CrossRef][Medline]

32. Bureau International des Poids et Mesures. 2005. What is metrology? http://www.bipm.org/en/bipm/metrology/.

33. Sambrook, J., and D. W. Russell. 2001. Molecular Cloning: A Laboratory Manual, 3rd Ed. Cold Spring Harbor Laboratory Press, Cold Spring Harbor, NY.

34. Baumann, C. G., S. B. Smith, V. A. Bloomfield, and C. Bustamante. 1997. Ionic effects on the elasticity of single DNA molecules. Proc. Natl. Acad. Sci. USA. 94:6185–6190.[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
Biophys. JHome page
J. P. Rickgauer, D. N. Fuller, S. Grimes, P. J. Jardine, D. L. Anderson, and D. E. Smith
Portal Motor Velocity and Internal Force Resisting Viral DNA Packaging in Bacteriophage {phi}29
Biophys. J., January 1, 2008; 94(1): 159 - 167.
[Abstract] [Full Text] [PDF]


Home page
Biophys. JHome page
Y. Seol, J. Li, P. C. Nelson, T. T. Perkins, and M. D. Betterton
Elasticity of Short DNA Molecules: Theory and Experiment for Contour Lengths of 0.6 7 {micro}m
Biophys. J., December 15, 2007; 93(12): 4360 - 4373.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
D. N. Fuller, D. M. Raymer, V. I. Kottadiel, V. B. Rao, and D. E. Smith
Single phage T4 DNA packaging motors exhibit large force generation, high velocity, and dynamic variability
PNAS, October 23, 2007; 104(43): 16868 - 16873.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
D. N. Fuller, J. P. Rickgauer, P. J. Jardine, S. Grimes, D. L. Anderson, and D. E. Smith
From the Cover: Ionic effects on viral DNA packaging and portal motor function in bacteriophage {varphi}29
PNAS, July 3, 2007; 104(27): 11245 - 11250.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
biophysj.106.089524v1
91/11/4253    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rickgauer, J. P.
Right arrow Articles by Smith, D. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rickgauer, J. P.
Right arrow Articles by Smith, D. E.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the Biophysical Society.