| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||


* School of Science, Pennsylvania State University at Erie, The Behrend College, Erie, Pennsylvania; and
Department of Physics and Astronomy, University of Pittsburgh, Pittsburgh, Pennsylvania
Correspondence: Address reprint requests to X. L. Wu, E-mail: xlwu{at}pitt.edu; or C. Yeung, E-mail: cxy11{at}psu.edu.
| ABSTRACT |
|---|
|
|
|---|
| INTRODUCTION |
|---|
|
|
|---|
Despite these advances, studying motion in cellular environments using FCS remains challenging. Diffusion is among only a handful of models for which FCS has an analytic solution. However, in the cell, species often interact with binding partners as well as structural elements, and rarely undergo pure diffusion. Often this motion is restricted by both cellular (11
) and intracellular boundaries. If these compartments are of the order of the laser beam radius W, then the measured correlation function deviates from the expected form. Lastly, the motion of intracellular species is typically slow with correlation half-decay times
1/2 commonly approaching seconds, less than two orders-of-magnitude smaller than the total integration time T. This leads to a significant finite T correction to the autocorrelation function (12
14
).
Recently FCS was used to study the dynamics of synaptic vesicles in hippocampal synapses (15
,16
). This system exhibits all the above properties that render solutions in these environments elusive. The vesicles enclose neurotransmitters, which are released in response to action potentials. The vesicles are 40 nm in size and are contained in a synaptic bouton that is only a few beam diameters in its lateral dimension (1 µm). The vesicles cannot be observed directly with light microscopy. However, they can be fluorescently labeled, the fluorescence intensity fluctuations resulting from movement in and out of the small detection volume can be measured, and the correlation function calculated. These FCS experiments were performed under a variety of conditions and supplemented by fluorescence recovery after photobleaching (FRAP) experiments. Together these experiments show:
2500 times larger than that for water and a diffusion constant
100 times larger than expected for inert particles of this size diffusing in the cell.
To understand this set of observations we proposed a stick-and-diffuse model in which the vesicles bind and release from the cellular cytomatrix. The vesicles are free to diffuse when not bound (2
). An alternative model based on the very slow dynamics and a very small value of normalized FCS autocorrelation function was also proposed by Jordan et al. (1
). They assumed a caged diffusion model in which the vesicles undergo diffusion in circular cages within the bouton.
Although both the stick-and-diffuse and the caged diffusion models are motivated by the observations of vesicle motions in central synapses, the dynamics described by these models are common in biological systems. For instance, gene regulation and signal transduction are often accomplished by reversible binding and unbinding of a protein to its substrate, including DNA, RNA, or other proteins (17
). The stick-and-diffuse model may be relevant for the diffusing protein. The caged diffusion model is relevant for the sterically restricted diffusion of biomolecules in the aqueous lumen of certain intracellular organelles, such as mitochondria and endoplasmic reticulum (18
). Recent studies also reveal that lateral diffusion of membrane proteins is corralled by the underlying cytoskeleton structures (19
,20
) and may also be described by caged diffusion. The close relations between these important cellular processes and the dynamic behaviors ascribed by the stick-and-diffuse and the caged diffusion models provide a strong motivation for solving the models analytically.
This article is organized as follows: First, the bias due to the finite integration time T is summarized. Next, we derive analytic expressions for the autocorrelation functions for the stick-and-diffuse model and for the caged diffusion model. This allows us to compare the predictions of the two models to our experimental FCS data. We find that the stick-and-diffuse model gives a significantly better description of our experimental result while the caged diffusion model gives fits similar to that for free diffusion. Finally, a Summary is provided, where additional lines of evidence in support of the stick-and-diffuse model are discussed.
| FINITE INTEGRATION TIME CORRECTION |
|---|
|
|
|---|
![]() | (1) |
...
indicates an ensemble average, I(s) is the detected intensity at time s, and
is the average of the intensity over the finite integration time T. On average,
, where
. This leads to a finite T bias (14
![]() | (2) |
(t) is the autocorrelation function for infinite T,
and
![]() | (3) |
(t) is always positive.
More recently, Schätzel et al. (15
) and Saffarian et al. (16
) has pointed out the advantage of a "symmetrically" normalized autocorrelation function,
![]() | (4) |
. Expanding to second-order in
gives
![]() | (5) |
To second-order in
the bias in the GT (t) comes entirely from the subtraction of
and
in Eq. 4. The effect of normalizing by the product
instead of by
in Eq. 4 contributes corrections at higher order in
.
The biases for the two normalization methods are essentially the same at short times but can be significantly smaller for symmetrically normalized case at long times. An example is given in Supplement S1 in the Supplementary Material. Another important advantage of symmetric normalization is that the variance is much smaller than in the asymmetric case (15
,16
).
| MODELS OF VESICLE DYNAMICS |
|---|
|
|
|---|
4050% relative to the mean. The raw fluorescent intensity I(t) was binned to
t = 0.01 s and then fitted to the form
, which mimics the trend-line of the fluorescence decay. The symmetrically normalized autocorrelation is given by
![]() | (6) |
...
indicates an ensemble average over the 39 runs and N = T/
t. The average intensities in the denominator are
![]() | (7) |
t. We found that the autocorrelation function was dominated by the trend-line if we did not subtract I'(t) but that the obtained autocorrelation function did not depend sensitively on the choice of the fitting form for the trend-line. We also found that fluctuations about the trend-line were not correlated with the trend-line, i.e.,
. See Supplement S2 in the Supplementary Material for a more detailed discussion of the effect of subtracting the trend-line. We note that while there was essentially no difference whether we normalized by
or
, the subtraction of the trend-line means that GT (ti) corresponds to the symmetrically normalized autocorrelation function.
|
3 s and that GT (t) is clearly negative at intermediate times. Fig. 2 shows the best fits of the experimental data to the different theoretical models. Fig. 2 a gives the comparison for two-dimensional free diffusion. There are two fitting parameters, the amplitude G
(0) and the diffusion time
D (see Table 1 for details of fitting parameters). The model is corrected for the finite integration time T = 200 s. The fits were performed by minimizing
2 defined as
![]() | (8) |
i is the uncertainty of GT at time ti. The calculation of the uncertainty was subtle due to the large heterogeneity in the amplitude of the autocorrelation function. This is discussed in more detail in the Supplementary Material. In most FCS experiments, the autocorrelation function is obtained online resulting in times ti that are distributed uniformly in log t. This allows one to investigate dynamics with multiple timescales. To mimic this, we prune our times which are originally uniformly distributed in time t so that we fit 51 data points uniformly distributed in log t between t = 0.01 s and t = 20 s. Following Jordan (1
50 times larger than that of the half-decay time. Therefore, due to the larger noise and the systematic effects of the decay in intensity, the longer time data does not discriminate between different models. As a result, we focus on the early time behavior t < 20 s. The fitting values in our previous article were slightly different. Our earlier fit did not take the uncertainty into account and also used the entire autocorrelation function 0 < t < 200 s weighted by 1/t.
|
|
(0) = 0.0170 ± 0.006 and
D = (2.8 ± 0.6) s corresponding to D = (4.3 ± 0.9) x 103(µm)2/s with
2 = 118. The uncertainty in
D was obtained by determining the values of
D at which
2 increased by a factor (M + 1)/M, where M = 2 is the number of adjustable fitting parameters. The probability that a
2 larger than this value occurs randomly for the model is (23
![]() | (9) |
(a, x) is the incomplete
-function, N = 51 is the number of data points in the fit, and N M is the degrees of freedom. We have assumed the fluctuations about the fit are distributed in a Gaussian manner and are independent. The probability of a random event yielding a
2 value >118 is therefore
(24.5, 59)/
(24.5) = 1.3 x 107. (See Table 1 for a summary of the fitting parameters for the different models.)
We also fitted the FCS data to one-dimensional free diffusion (fit not shown). The fitting quality was approximately the same as for two-dimensional diffusion with
D = (1.1 ± 0.3) s corresponding to a diffusion constant D = (1.1 ± 0.3) x 102(µm)2/s and
2 = 130. The probability of a larger
2 occurring randomly is 3 x 109. Therefore, both one-dimensional and two-dimensional diffusion can be ruled out.
Finally, we also fit the experimental data to a two-component diffusion model. As expected, the fit is much better (
2 = 50.3) than for the single component two-dimensional diffusion but, as we will discuss later, worse than that for the stick-and-diffuse model. The probability of a larger
2 is 0.35. Therefore, two-component diffusion cannot be ruled out based on goodness of fit. However, we found a reasonable fit only occurs when the two components have widely different timescales
D1 = 3.5 s and
D2 = 0.06 s. The vesicles were synthesized by a clathrin pathway and ultra-structure studies using electron-microscopy show extremely uniform size-distribution of vesicles (24
). This uniformity rules out one of the common causes of variations in the particle diffusivity; that is, the particle size distribution. Although it is not possible to completely rule out other sources of heterogeneity, it is difficult to see how either inter- or intracellular variation can lead to such a wide separation in the two diffusion times. The two component diffusion model is also difficult to reconcile with the following observations: 1), FRAP data in which exponential recovery is observed; 2), the large changes in the FCS autocorrelation functions when changing temperature; and 3), the diffusionlike behavior on application of phosphatase inhibitor okadaic acid (OA) (2
). For the OA case, we found that the autocorrelation function was well fitted by single-component diffusion with a characteristic diffusion time similar to the free state diffusion time in the stick-and-diffuse model. Details of the fit to the two-component diffusion model are given in Supplement S4 in the Supplementary Material.
Stick-and-diffuse model
Autocorrelation function
Previous studies have established that synaptic vesicles in central nerve systems are divided into distinct functional pools. These include a readily releasable pool that is docked at an active site and a reserve pool that is remote from the active site (25
). However, it is unclear from these earlier experiments how the readily releasable pool is replenished by the reserve pool after the docked vesicles are released. We addressed this kinetic question directly using FCS and FRAP by monitoring the mobility of vesicles under different conditions (2
). Our experiment showed that only a small fraction of the reserve pool vesicles is mobile and therefore able to dock in the active zone, thereby playing a role in chemical transmission. We also found that the mobile pool fraction can be modulated by increasing the bath temperature and by application of the phosphatase inhibitor, OA. The diffusion constant of mobilized vesicles is 30 times larger and is the same order of free diffusion of comparable-sized objects in a cytoplasmic environment. These observations suggest that a synaptic vesicle has two intrinsic states, a state in which the vesicle is bound, presumably to the cellular cytomatrix, and a second unbound state in which the vesicle is free to diffuse. However, it is unclear whether this stick-and-diffuse model of vesicles can account for the autocorrelation function observed in our FCS measurements, and more importantly if the parameters extracted from the FCS measurements can be compared with the data from electrophysiological measurements (25
). With these in mind, we set out to derive the autocorrelation function based on stick-and-diffuse phenomenology. A very rough sketch of the derivation of the FCS autocorrelation for this model was given in our previous article (2
). Here we give a detailed derivation of the autocorrelation function.
We assume that the bound state is a Poisson process with unbinding rate 1/
b and the unbound state is a Poisson process with binding rate 1/
u. Therefore, the average bound and unbound intervals are
b and
u, respectively. Once unbound, the free particle has a diffusion time
D = W2/D in the light box formed by a tightly focused laser beam (see Supplement S6 in the Supplementary Material). The steady-state probability that a vesicle is, respectively, bound and unbound are
![]() | (10) |
To calculate G
(t), let us assume that during time t a vesicle is free for time s1, then bound for time b1, then free for time s2 and so on, such that s = s1 + s2 + ... and t s = b1 + b2 + .... The autocorrelation function at time s1 is therefore the same as if the vesicle underwent free diffusion for time s1, that is,
, where
r(s1)2
= 4Ds1 is the mean-square displacement for the free diffusion process. The vesicle is frozen for time b1, so the intensity does not change during this time and the autocorrelation function is constant:
. The vesicle then becomes free to diffuse for time s2. At the end of time s2, it is clear that the vesicle will be in the same position as if it had undergone free diffusion for time s1 + s2. Since the contribution of a vesicle to the autocorrelation function at time t depends only on the vesicle positions at time 0 and t, this implies that the autocorrelation function at time s1 + b1 + s2 is the same as that of free diffusion at time s1 + s2, e.g.,
, where
is the mean-square displacement for free diffusion after time s1 + s2. Repeating this argument for all the segments shows that the autocorrelation function after time t depends only on the total free time s = s1 + s2 + ... and not on the individual free segments. Furthermore the vesicle at time t is in the same position as if it had undergone free diffusion for time s so that the vesicle's contribution to the autocorrelation function at time t is the same as for a vesicle undergoing free diffusion for time s:
.
Since the vesicles are independent, we can sum up the contribution from each vesicle. However all values of total free time s < t are possible. Therefore we need to sum up over all possible values of s weighted by the probability P(s, t)ds that the vesicle is free for total time between s and s + ds during time interval t:
![]() | (11) |
![]() | (12) |
is the conditional probability density given that the vesicle is unbound at the beginning of the interval, that there is total free time s in n free intervals and total bound time t s in m bound intervals.
is the same except that the vesicle is bound at the beginning of the interval.
Start with the case where a vesicle is initially unbound. Assume there are n + 1 unbound intervals and n bound intervals where n
1. We need two conditions to find
. The first is that there are n binding events in time s for a Poisson process that occurs with binding rate 1/
u. This probability is given by a Poisson distribution with mean value s/
u,
![]() | (13) |
b. This probability density is given by the Erlang distribution,
![]() | (14) |
![]() | (15) |
![]() | (16) |
![]() | (17) |
![]() | (18) |
(t) is calculated. In general, Eq. 18 must be solved numerically but the model can be easily understood in two limits:
b <<
D <<
u: The vesicle essentially undergoes free diffusion. Only the second term in Eq. 18 is nonnegligible, and
![]() | (19) |
b,
u <<
D: There are many binding and unbinding events before the vesicle moves through the detection area. For times t >>
u,
b, this is effectively diffusion with a reduced diffusion constant D' =
uD/(
u +
b) and/or increased diffusion time
'D = (
u +
b)
D/
u:
![]() | (20) |
We performed direct simulations of the stick-and-diffuse model to test the theoretical expression Eq. 18 and the limiting behavior given by Eqs. 19 and 20. Results were obtained for
b = 0.1 s,
D = 1 s, and
u = 10 s, and also for
b = 0.2 s,
D = 2 s, and
u = 0.1 s to test limiting behavior. We also performed simulations for
b = 4.2 s,
D = 0.22 s, and
u = 2.0 s, which, as we show below, are the parameters we obtained from fitting the experimental autocorrelation function to the stick-and-diffuse model. In all cases, agreement with the theoretical expression Eq. 18 was excellent. See Supplement S3 in the Supplementary Material for more details concerning the simulation method and results.
Comparison of stick-and-diffuse model with experimental FCS
Fig. 2 b shows the fit of our FCS data to the stick-and-diffuse model. The fit was performed the same way as for the free diffusion case. We determined G
(t) by evaluating Eq. 18 numerically and then determined GT(t) using Eq. 5. The four fitting parameters were
b = (4.2 ± 0.4) s,
u = (2.0 ± 0.4) s,
D = (0.22 ± 0.07) s, and amplitude G
(0) = 0.0176 ± 0.0002. The fit is significantly better than for free diffusion, with
2 = 10.4 being a factor-of-11 smaller. The probability of obtaining a
2 >10.4 is almost 1 (0.999999996). This is likely an indication that we overestimated the uncertainties of GT(t) and/or the fluctuations are not independent (see explanation following Eq. 8).
The fitted value of the diffusion constant, D = W2/
D = (5.4 ± 1.6) x 102(µm)2/s, was consistent with the diffusion constant measured when OA was used to release the vesicles from the cellular cytomatrix, D
1 x 101(µm)2/s (2
). This procedure eliminates the bound state leaving only the free state. The average binding time
b
4 s was also consistent with the timescale observed in vesicle refilling experiments (26
,27
) and our measurements of the time required for the fluorescent signal to recover after photobleaching (2
).
Therefore the stick-and-diffuse model predicts that, on average, a vesicle bound state lasts
4 s and the vesicle free state lasts on average 2 s. During the free period the vesicle can explore the entire detection area since
u/
D
10 and the intensity is essentially uncorrelated between bound states. As a result, the long time correlation function is determined by
b and the autocorrelation function is not very sensitive to the details of the short time dynamics as indicated by the large fractional uncertainty in
D. This insensitivity holds as long as the vesicle has time to explore the detection volume during an average free interval.
To further demonstrate the insensitivity of the result to the short time dynamics, we also fitted the experimental FCS autocorrelation function to the stick-and-diffuse model assuming that the diffusion is effectively one-dimensional in its free state. The fit quality is only slightly worse than for the stick-and-diffuse model in two dimensions with
2 = 21.7. The probability of a larger
2 is 0.9994 again indicating that our estimates of the uncertainty are too large. We find that
u = (1.8 ± 0.4) s,
b = (3.6 ± 0.5) s is only slightly changed from the two-dimensional result but
D = (0.085 ± 0.045) s is
65% lower. In fact we expect similar quality of fit even if the short time motion was nondiffusive as long as the dynamics are fast enough so that the vesicles can move through the detection area during a free segment and the direction of motion is uncorrelated from one free segment to the next.
Caged diffusion model
Autocorrelation function
Jordan et al. (1
) proposed a caged diffusion model to explain their FCS data. They assumed that each vesicle is restricted to a circular cage of radius a. The vesicle is assumed to undergo diffusion with diffusion constant D inside this circular cage. For simplicity, the cages are assumed to be located randomly within the bouton and the vesicles are assumed to be independent. In this section we will obtain an expression for the FCS autocorrelation function for the caged diffusion model and compare the results with our FCS data.
Consider a single vesicle in a cage of radius a with the cage center at R. The nonnormalized autocorrelation function g(t) is defined by
![]() | (21) |
is the absorbance, and Io(r) is the laser beam intensity profile. The brackets 
R indicate an average over all initial conditions r0 inside the cage. The concentration C1(r, t) is the solution to the diffusion equation
![]() | (22) |
![]() | (23) |
a2 of the cage. Assuming a Gaussian beam profile and N independent particles in N cages centered at Ri, i = 1, ..., N, gives
![]() | (24) |
![]() | (25) |
is much larger than the detection area and that the positions of the cages are not correlated.
Solving the diffusion equation (Eq. 22) in cylindrical coordinates with no flux boundary condition
gives
where Anmp are constants that depend on the initial position of the vesicle and the functions
n,m,p(r) form the orthonormal basis for the Laplacian in cylindrical coordinates (28
). The basis functions factor into a radial and angular part,
n,m,p(r) =
n,m(r)
m,p(
),
![]() | (26) |
.
Taking C1(r, 0) =
(r ro) and then averaging over all initial positions ro inside the cage of radius a gives the concentration-concentration correlation:
![]() | (27) |
![]() | (28) |
term in Eq. 21. The time required for the vesicle to diffuse through the cage is
a = a2/D and
![]() | (29) |
Here Fm(y) is the angular part of the integration:
![]() | (30) |
![]() | (31) |
![]() | (32) |
(t)/G
(0) = f(t/
a, a/W) is a function only of t/
a and a/W. Fig. 3 a shows this ratio as a function over t/
a for different a/W. The symbols are results of direct simulation of the caged diffusion model. There is an excellent match between the analytical and the simulation results.
|
D = W2/D = (W/a)2
a. (In this limit, the sums in Eq. 32 can be converted to an integral over q = kmn/a. The exponential
becomes exp(Dq2t), thereby giving free diffusion.) Fig. 3 b shows a comparison of the caged diffusion model for a/W = 5 with two-dimensional free diffusion. The curves coincide for t/
D < 4. At longer times the finite cage size becomes important. The effect is similar to the finite sample size corrections given by Gennerich and Schild (13
: The autocorrelation function is essentially independent of the ratio a/W as long as
. As shown in Fig. 3 c, G
(t) is dominated by the m = 1, n = 0 term in Eq. 32 and
, where
. This is the slowest decaying mode since
. The decay is a good single exponential for a/W as large as 1.
Comparison of caged diffusion with experimental FCS
Jordan et al. (1
) compared their FCS power spectrum with simulations of the caged diffusion model. They found that the experimental power spectrum very roughly matched their simulations when they assumed a beam radius of
85 nm, a cage size of between 50 and 100 nm and a very small diffusion constant of
5 x 105 (µm)2/s. Fig. 2 c shows the best fit of our experimental FCS autocorrelation to the caged diffusion model with our beam radius W = 110 nm. The fitting parameters were a = (360 ± 140) nm, D = (3.7 ± 1.5) x 103(µm)2/s, and G
(0) = 0.0164 ± 0.0006. The fit is significantly worse than for the stick-and-diffuse model. We find
2 = 99.3 with the probability of a larger
2 being 0.000019. This value of
2 is only slightly smaller than the fits to free diffusion. In particular, the diffusion time
D = W2/D
(3.3 ± 1.3) s is close to the diffusion time,
D = (2.7 ± 0.7) s, obtained from the fit to two-dimensional free diffusion. This is because a/W
3.5 so the finite cage size has little effect except at late times.
Our best fit parameters are in a different regime from those obtained by Jordan et al. (1
). In their case they found
and a much smaller diffusion constant. Therefore we also fit the caged diffusion model with the cage radius fixed at a = 75 nm. Fig. 2 d shows the best fit with a = 75 nm and W = 110 nm fixed. The fit is poor with
2 = 202, approximately twice that of this model when we allow a to be adjusted. The fitting parameters were D = (3.6 ± 0.8) x 104 (µm)2/s and G
(0) = (0.0161 ± 0.0006). The diffusion constant is approximately seven times larger than the value obtained in Jordan et al. (1
). However, the functional form is not very dependent on a/W for a < W so fixing a to 50 nm gives a similar fit with D very similar to the value they obtained.
| SUMMARY |
|---|
|
|
|---|
D
0.2 s, D
0.05 (µm)2/s) agrees well with the diffusion time measured in FCS experiments on synapses exposed to OA (
1/2
0.1 s, D
0.1 (µm)2/s), where vesicles are unbound and diffuse freely. These dynamics agree reasonably well with the diffusion time measured for inert particles of this size in cells (29
300-times larger. Next, changing the temperature of the system by several degrees dramatically alters the vesicle dynamics. This is not consistent with pure or caged diffusion, and is indicative of an enzymatic process such as phosphorylation-dependent binding. Lastly, the stick-and-diffuse model predicts both the FRAP and the previously published electrophysiological refilling results (26
b consistent with the exponential recovery time. These features cannot be addressed by the caged diffusion model, which predicts no fluorescence recovery or vesicle refilling. Therefore the stick-and-diffuse model is consistent with existing kinetic measurements of vesicle dynamics in synapses. The model makes specific predictions about how the vesicles move about in synapses and may be further tested in future experiments using single-molecule techniques. The analytic expressions for the autocorrelation function may also be useful for analyzing FCS data in other biological systems, which is suspected of undergoing bind-and-diffuse dynamics or caged diffusion dynamics.
| SUPPLEMENTARY MATERIAL |
|---|
|
|
|---|
| ACKNOWLEDGEMENTS |
|---|
|
|
|---|
This work was partially supported by the University of Pittsburgh Andrew Mellon predoctoral fellowship to M.S. and National Science Foundation grant No. DMR 0242284 to X.L.W.
Submitted on January 24, 2006; accepted for publication November 27, 2006.
| REFERENCES |
|---|
|
|
|---|
2. Rigler, R., and E. Elson. 2001. Fluorescence Correlation Spectroscopy, Theory and Application. Springer-Verlag, Berlin.
3. Hess, S., S. Huang, A. Heikal, and W. Webb. 2002. Biological and chemical applications of fluorescence correlation spectroscopy: a review. Biochemistry. 41:697705.[CrossRef][Medline]
4. Schwille, P. 2001. Fluorescence correlation spectroscopy and its potential for intracellular applications. Cell Biochem. Biophys. 34:383408.[CrossRef][Medline]
5. Thompson, N., A. Lieto, and N. Allen. 2002. Recent advances in fluorescence correlation spectroscopy. Curr. Opin. Struct. Biol. 12:337378.[CrossRef][Medline]
6. Magde, D., E. Elson, and W. Webb. 1974. Fluorescence correlation spectroscopy. II. An experimental realization. Biopolymers. 13:2961.[CrossRef][Medline]
7. Ehrenberg, M., and R. Rigler. 1974. Rotational Brownian motion and fluorescence intensity fluctuations. Chem. Phys. 4:390401.[CrossRef]
8. Aragón, S., and R. Pecora. 1975. Fluorescence correlation spectroscopy and Brownian rotational motion. Biopolymers. 14:119138.[CrossRef]
9. Magde, D., and E. Elson. 1978. Fluorescence correlation spectroscopy. III. Uniform translation and laminar flow. Biopolymers. 17:361376.[CrossRef]
10. Widengren, J., U. Mets, and R. Rigler. 1995. Fluorescence correlation spectroscopy of triplet states in solution: a theoretical and experimental study. J. Phys. Chem. 99:1336813379.[CrossRef]
11. Gennerich, A., and D. Schild. 2000. Fluorescence correlation spectroscopy in small cytosolic compartments depends on the diffusion model used. Biophys. J. 79:32943306.
12. Jakeman, E., E. Pike, and S. Swain. 1971. Statistical accuracy in the digital autocorrelation of photon counting fluctuations. J. Phys. A. 4:517534.[CrossRef]
13. Schätzel, K., M. Drewel, and S. Stimac. 1989. Photon correlation measurements at large lag times: improving statistical accuracy. J. Mod. Opt. 35:711718.
14. Saffarian, S., and E. L. Elson. 2003. Statistical analysis of fluorescence correlation spectroscopy: the standard deviation and bias. Biophys. J. 84:20302042.
15. Jordan, M., E. Lemke, and J. Klingauf. 2005. Visualization of synaptic vesicle movement in intact synaptic boutons. Biophys. J. 89:20912102.
16. Shtrahman, M., C. Yeung, D. Nauen, G. q. Bi, and X. Wu. 2005. Probing vesicle dynamics in single hippocampal synapses. Biophys. J. 89:36153627.
17. Lippincott-Schwartz, J., E. Snapp, and A. Kenworthy. 2001. Studying protein dynamics in living cells. Nat. Rev. Mol. Cell Biol. 2:444456.[CrossRef][Medline]
18. Verkman, A. 2002. Studying protein dynamics in living cells. Trends Biochem. Sci. 27:2733.[CrossRef][Medline]
19. Brown, F., D. Leitner, J. McCammon, and K. Wilson. 2000. Studying protein dynamics in living cells. Biophys. J. 78:22572269.
20. Kusumi, A., C. Nakada, K. Ritchie, K. Murase, K. Suzuki, H. Murakoshi, R. S. Kasai, J. Kondo, and T. Fujiwara. 2005. Paradigm shift of the two-dimensional continuum fluid to the partitioned fluid: high-speed single-molecule tracking of membrane molecules. Annu. Rev. Biophys. Biomol. Struct. 34:351378.[CrossRef][Medline]
21. Reference deleted in proof.
22. Reference deleted in proof.
23. Press, W., B. Flannery, S. Teukolsky, and W. Vetterling. 2002. Numerical Recipes. Cambridge University Press, London.
24. Sudhof, T. 1995. The synaptic vesicle cycle: a cascade of protein-protein interactions. Nature. 375:645653.[CrossRef][Medline]
25. Schikorski, T., and C. Stevens. 2001. Morphological correlates of functionally defined synaptic vesicle populations. Nat. Neurosci. 4:391395.[CrossRef][Medline]
26. Stevens, C., and J. Wesseling. 1999. Identification of a novel process limiting the rate of synaptic vesicle cycling at hippocampal synapses. Neuron. 27:539550.
27. Morales, M., M. Colicos, and Y. Yoda. 2000. Actin-dependent regulation of neurotransmitter release at central synapses. Neuron. 27:539550.[CrossRef][Medline]
28. Farlow, S. 1993. Partial Differential Equations for Scientist and Engineers. Dover, Mineola, New York.
29. Luby-Phelps, K., P. E. Castle, L. D. Taylor, and F. Lanni. 1987. Hindered diffusion of inert tracer particles in the cytoplasm of mouse 3t3 cells. Proc. Natl. Acad. Sci. USA. 84:49104913.
30. Holt, M., A. Cooke, A. Neef, and L. Lagnado. 2004. High mobility of vesicles supports continuous exocytosis at a ribbon synapse. Curr. Biol. 14:173183.[CrossRef][Medline]
31. Rea, R., J. Li, A. Dharla, E. S. Levitan, P. Sterling, and R. H. Kramer. 2004. Streamlined synaptic vesicle cycle in cone photoreceptors terminals. Neuron. 41:755766.[CrossRef][Medline]
This article has been cited by other articles:
![]() |
V. Westphal, S. O. Rizzoli, M. A. Lauterbach, D. Kamin, R. Jahn, and S. W. Hell Video-Rate Far-Field Optical Nanoscopy Dissects Synaptic Vesicle Movement Science, April 11, 2008; 320(5873): 246 - 249. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||