| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Clarendon Laboratory, Department of Physics, University of Oxford, Oxford, United Kingdom
Correspondence: Address reprint requests to Richard Berry, Clarendon Laboratory, Dept. of Physics, University of Oxford, Parks Rd., Oxford OX1 3PU, U.K. Tel.: 44-0-1865-282559; Fax: 44-0-1865-272400; E-mail: r.berry1{at}physics.ox.ac.uk.
| ABSTRACT |
|---|
|
|
|---|
| INTRODUCTION |
|---|
|
|
|---|
pI). In Escherichia coli and Vibrio alginolyticus, motors are powered by proton (H+) and sodium ion (Na+) flux, respectively. Using tethered cells and polystyrene beads attached to flagella to measure the speed of rotation of the E. coli motor, it has been shown that the speed is proportional to protonmotive force (PMF) (3
pH) are equivalent in driving the motor (5
pH are strongly correlated and difficult to manipulate independently. As external pH decreases, internal pH also decreases, but not as much, so that the inward-directed
pH increases. At the same time, the inward-directed Vm decreases, but not enough to compensate for the increase of
pH, with the overall result that the PMF becomes larger (7
In this work, we studied chimeric sodium-driven flagellar motors in E. coli, containing rotors from the proton-driven E. coli motor and stators that combine proteins from proton-driven E. coli and sodium-driven V. alginolyticus motors (9
11
). To investigate the dependence of the motor mechanism on sodium-motive force (SMF), we developed a method to measure Vm in single cells using the Nernstian fluorescent dye, tetramethyl rhodamine methyl ester (TMRM). Combining this method with single-cell measurements of intracellular sodium concentration ([Na+]in) and motor speed (11
), we demonstrated that Vm and
pNa in E. coli can be manipulated independently by external pH (pHex) and external sodium concentration ([Na+]ex), respectively. Using 1-µm-diameter beads to measure the rotation rate of the chimeric motor under high load, we found that speed is proportional to SMF, and that Vm and
pNa are equivalent in driving the motor. This confirms earlier, similar, results for the proton-driven motor. However, under low load with 0.35-µm-diameter beads, the speed was greater with high [Na+]ex and a larger
pNa component of the SMF than with lower [Na+]ex and a larger Vm component of the SMF. Thus, Vm and
pNa are not equivalent as driving forces for the flagellar motor, possibly indicating that the arrival of sodium ions is the rate-limiting step in low sodium concentration.
Quantitative measurement of Vm using cationic indicator dyes is based on equilibration of the dye across the membrane according to Boltzmann's law:
![]() | (1) |
![]() | (2) |
The dye should have high membrane permeability to ensure rapid equilibration and low toxicity to avoid perturbing the cell. Cin and Cex are the concentrations of free dye in aqueous solution, as distinct from any dye molecules that are bound to the cell membrane or otherwise immobilized. Thus minimal binding of the dye to membranes and other intra- or extracellular components is desirable, so that the ratio Cin/Cex can be determined accurately from fluorescence intensities. A typical bacterial membrane potential is around 150 mV, corresponding to Cin/Cex
350. This can lead to high concentrations of dye inside the cell, which can in turn lead to aggregation and quenching of fluorescence. Whereas this effect can be used as a qualitative indicator of Vm (12
), quantitative measurements should avoid aggregation by using low concentrations of dye. Thus bright fluorescence, low photobleaching, and low aggregation and self-quenching are further desirable properties of the dye. Many hydrophobic membrane potential dyes have been designed to determine Vm of cells and mitochondria in vivo (13
16
). In particular, the dye TMRM has been shown to be suitable for quantitative measurements of Vm in mitochondria (14
).
Because bacteria (and mitochondria) are similar in size to the diffraction limit of a light microscope, the fluorescence intensity of pixels within the image of a single bacterium is not simply proportional to Cin, but also includes contributions from adjacent extracellular regions. Typically, Cin is greater than Cex, thus the brightness of the cell image is reduced compared to a solution of the same concentration, and the ratio of internal to external fluorescence intensities underestimates the ratio Cin/Cex. Loew's group has reported the measurement of Vm in individual mitochondria using TMRM fluorescence, correcting for the brightness reduction by measuring the point spread function (PSF) of the microscope and modeling the convolution process that reduces the brightness of the mitochondrial image (14
,16
). In this work, we adapted this technique to develop a single-cell fluorescence measurement of Vm in bacteria. We imaged E. coli cells immobilized at low density on a microscope coverslip, giving a very well-defined geometry well suited to optical convolution modeling. By using a high quantum-efficiency electron-multiplying charge-coupled device (EMCCD) camera, we obtained low-noise images using external TMRM concentrations of 0.1 µM and image exposure times of 1030 ms. E. coli is a gram-negative bacterium with an outer membrane that acts as a barrier to the permeation of hydrophobic molecules such as TMRM. To increase the permeability of the dye with minimal damage to cell function, we pretreated cells with EDTA (11
).
| MATERIALS AND METHODS |
|---|
|
|
|---|
cheY, fliC::Tn10,
pilA,
motAmotB) (10
Sample preparation
Cells were suspended in sodium motility buffer (10 mM potassium phosphate, 85 mM NaCl, pH 7.0) plus 10 mM EDTA for 10 min to increase permeability to dye (11
), then washed three times in sodium motility buffer. Cells at a density of 108 cells/ml were suspended in sodium motility buffer plus 0.1 µM TMRM (MIP, Ann Arbor, MI) and loaded into custom-built flow chambers (volume
5 µl), in which they were immobilized on polylysine-coated coverslips (11
). For speed measurements, cells were sheared to truncate flagella, polystyrene beads (1.0 and 0.35 µm in diameter; Polysciences, Warrington, PA) were attached to flagella, and the speed/independent stator unit was measured using back-focal-plane interferometry or high-speed microscopy, as described (10
,11
,17
,18
). For each cell, speeds were calculated from the Fourier transform of bead position in data windows 15 s long beginning at 0.1-s intervals, for a total of 1020 s. With low-level induction of stator proteins, speed histograms combining data from many cells under the same conditions showed distinct peaks corresponding to discrete numbers of stator units (see Fig. 4, A and D, and Reid et al. (17
)). For 0.35-µm beads the speed with a single unit was obtained by a Gaussian fit to the slowest peak. For 1-µm beads the speed/unit was obtained by dividing the speeds with 15 units (obtained from a multiple-Gaussian fit to the speed histogram) by the number of units, and then averaging these five independent estimates. Intracellular sodium measurements were performed on single cells using the fluorescent indicator dye Sodium Green as described (11
).
|
5 W/cm2 (±2%). The sample flow chamber was mounted on a piezoelectric stage (P-517.3cl, PI, Karlsruhe, Germany). Fluorescence emission was passed through the dichroic mirror, an emission filter (580-nm band-pass) and a notch rejection filter (532 nm) and imaged at 50 nm/pixel onto a cooled 128 x 128-pixel array of a back-illuminated EMCCD camera (iXon, DV860-BI, Andor, Belfast, UK). All experiments were performed at 23°C.
Internal fluorescence intensity
Images of bacteria with pixel intensities I(xi, yi) were obtained with the focal plane passing through the center of the bacteria and an exposure time of 1030 ms. The total fluorescence intensity (FT) of a cell was defined as the average intensity of the central part of the cell, ignoring the marginal area and subtracting the background:
![]() | (3) |
![]() | (4) |
60 cells after loading and CCCP treatment as described above in buffers of the appropriate pH. The internal fluorescence due to free dye was estimated for each single-cell measurement as
![]() | (5) |
|
350 times greater than Cex when the Vm = 150 mV. If the camera exposure time were set to match the pixel intensities within the cell image to the full 14-bit dynamic range of the EMCCD, the external fluorescence intensity (Fex) would be close to the noise level. Therefore, we obtained Fex as follows. We filled the flow cell with 0.1 µM TMRM in sodium buffer and imaged empty areas with the focal plane 0.45 µm above the coverslip surface, corresponding to the height of the center of a cell. (The coverslip surface was easily found by searching for slight scratches.) We defined
![]() | (6) |
was measured at a given illumination laser power with different exposure times in the range 0.11.0 s, and Fex was defined as the slope of a line fit of
versus exposure time, multiplied by the exposure time for cell images, 1030 ms.
Point spread function
The PSF, P(xi, yi, zi), was defined as the pixel intensity I(xi, yi) in images of single 20-nm fluorescent beads (Molecular Probes, Eugene, OR) stuck to the coverslip at x = y = 0 and at a distance zi below the focal plane. The piezoelectric stage was used to scan zi over the range ±2.5 µm in 50-nm intervals (the image pixels are 50 nm2, giving a cubic grid). Three images with exposure times of 0.1 s were averaged for each zi. The PSF was normalized after background subtraction and correcting for photobleaching (Fig. 1 B).
|
![]() | (7) |
![]() | (8) |
Calculation of Vm
We calculated Vm using the Nernst equation, Eq. 2, and the corrected concentration ratio
![]() | (9) |
| RESULTS |
|---|
|
|
|---|
Fig. 2 A shows the total fluorescence intensity FT during the loading of dye into live cells in different pHex (solid symbols). The fluorescence intensities increased exponentially to a steady state within
30 min; exponential fits gave time constants of 10 ± 0.8, 14 ± 2, and 10 ± 2 min (mean ± SD) for pH 8, pH 7, and pH 6, respectively. The effect of 50 µM CCCP, a proton ionophore that eliminates the membrane potential, is shown for cells in pH 7 (open circles). FT decreases exponentially (within
30 min, fitted time constant 12 ± 3 min) to a stable nonzero value, FT = FM, indicating membrane binding of the dye (dashed line).
CCCP effect
The effect on cell fluorescence of 40 min incubation with a wide range of CCCP concentrations (0.150.0 µM), at pH 7, is shown in Fig. 2 B (upper). As in Fig. 2 A, the residual fluorescence intensity at high CCCP concentration is due to membrane binding of the dye. We estimated the fluorescence intensity due to membrane binding, Fm, as the average fluorescence intensity of cells treated with 50 µM CCCP (Methods). Fig. 2 B (lower) shows the membrane voltage, Vm, calculated as described in Methods, as a function of CCCP concentration. Vm decreases to zero with increasing [CCCP], indicating that CCCP may be used to achieve low values of Vm in experiments to investigate motor speed or other physiological functions. However, there was considerable intercellular variation in the value of Vm at a given CCCP concentration, as indicated by the large standard deviation (Fig. 2 B, lower, error bars). This illustrates the need to measure Vm in each cell if CCCP is to be used to control Vm.
Dependence of Vm and
pNa upon pHex and [Na+]ex
Fig. 3 A shows the dependence of Vm on pHex for E. coli cells expressing either sodium-driven chimeric or proton-driven wild-type flagellar motors. Vm decreases from 140 ± 14 to 85 ± 10 mV as pH changes from 7 to 5 with chimeric motors, and from 134 ± 17 to 85 ± 13 mV with wild-type motors. We previously showed that sodium influx through the chimeric motors is a significant part of the total sodium flux in a cell (11
). The absence of any significant difference in Vm between cells expressing proton- and sodium-driven motors indicates that Vm is not affected by the extra sodium flux through chimeric motors, as expected if Vm is dominated by the proton cycle in E. coli and relatively insensitive to the sodium cycle.
|
3 mV, see Discussion). Thus, the standard deviation reflects intercellular variation in the value of Vm at a given pHex and [Na+]ex. (Other error bars in Fig. 3 represent the mean ± SE of 50 cells measured.)
We previously reported the dependence of the internal sodium concentration [Na+]in and the sodium concentration gradient
pNa upon [Na+]ex in E. coli at pH 7 (11
). Here we use the same method to explore further the dependence of
pNa upon pHex and [Na+]ex (Fig. 3, C and D).
pNa depends weakly upon pHex (Fig. 3 C) and strongly upon [Na+]ex (Fig. 3 D). We performed least-squares global fits of the dependence of Vm and
pNa upon pHex and [Na+]ex to a log-linear model:
![]() | (10) |
![]() | (11) |
pNa (Fig. 3, C and D), the best-fit parameters (expressing
pNa in units of mV) were d = 5 ± 4 mV, e = 5 ± 1 mV/(pH unit), and f = 47 ± 1 mV/decade (errors are at 95% confidence limit). The global fits are shown as solid lines in Fig. 3. Thus to a reasonable approximation, Vm depends upon pHex but not upon [Na+]ex, and
pNa depends upon [Na+]ex but not upon pHex. This allows independent control of the two components of the SMF using pH and sodium concentration as the control parameters.
Motor speed versus SMF
First we measured the speed of 1-µm polystyrene beads attached to chimeric flagellar motors (11
,17
) as a function of pHex and [Na+]ex (Fig. 4, AC). Fig. 4 C shows the data of Fig. 4 B as speed versus SMF. The motor speed varies linearly with SMF, from 8.7 to 2.2 Hz/stator over the range 187 to 54 mV. In this high load condition, the two components of SMF, Vm and
pNa, are equivalent to within the limits of experimental uncertainty. Similar measurements, using 0.35-µm beads, are shown in Fig. 4, DF. For a given value of [Na+]ex (and thus also [Na+]in and
pNa), the motor speed varies linearly with SMF as Vm is varied via changes in pHex. However, the slope, and therefore the motor speed at a given SMF, is lower at low [Na+]ex than at higher [Na+]ex. Vm and
pNa are not equivalent as driving forces of the flagellar motor in the low-load region.
| DISCUSSION |
|---|
|
|
|---|
0.81.0 µm and the length is
3 µm. By varying the dimensions of model cells in the optical convolution calculation, we found that variations of cell length had negligible effect on the correction factor, whereas the uncertainty in cell diameter leads to an uncertainty of 11% in the correction factor.
15 mV corresponds to a fivefold variation in dye concentration inside the cell; the higher the dye concentration inside the cell, the higher the expected level of membrane binding.
Combining the contributions of these uncertainties to our estimate of Vm (Methods), the uncertainty is <3% at negative values beyond 110 mV, increasing to 5% at 90 mV, 10% at 70 mV, 50% at 40 mV, 100% at 30 mV. Precision at high membrane voltages is helped by the logarithmic nature of the Nernst equation. Under our experimental conditions, Vm in E. coli cells had negative values >80 mV and the uncertainty is <
6%. To increase the accuracy of measurements of low values of Vm, we can calibrate the membrane binding of each individual cell by applying 50 µM CCCP at the end of an experiment, removing this contribution to the uncertainty. By this method, the estimated uncertainty is <5% at 80 mV, 18% at 40 mV, and 100% at 10 mV.
Comparison to other Vm measurements
Our measurements of Vm in single E. coli cells are consistent with previous results. Felle et al. measured Vm in E. coli using the distribution of radio-labeled permeant cations TPP+ and TPMP+ (20
). The distribution of these ions follows the Nernst equation and their uptake can be determined by dialysis or filtration. They found that Vm increased linearly from 80 mV at pH 5 to 130 mV at pH 7, a slope of 25 mV/pH unit (compared to our measured value of 28 mV/pH unit). Also using E. coli and the same experimental method, Castle et al. measured Vm = 176 mV at pH 8.5 and 130 mV at pH 6.5 (23 mV/pH unit) (21
), and Minamino et al. (7
) measured Vm = 130 mV at pH 8.0 and 54 mV at pH 5.0 (24 mV/pH). Novo et al. measured Vm = 120 mV in Staphylococcus aureus and Micrococcus luteus using the aggregation and redshift of cyanine dye (22
). Suzuki et al. measured Vm changes induced by a K+ diffusion potential in E. coli and Rhodospirillum rubrum using the aggregation and quenching of carbocyanine dye (23
). This cationic dye can permeate the membrane freely and redistributes according to the Nernst equation. The high concentration of dye inside the cell at high Vm causes aggregation and thus quenches the fluorescence of the whole sample. However, the authors did not report measurement of the natural Vm in either species.
Unlike our method, all of the above measurements represent ensemble averages of a large number of cells. Felle et al. measured Vm = 135 mV at pH 7 in giant E. coli spheroplasts using a patch-clamp micropipette. Although this is a single-cell method, the production of giant spheroplasts is more disruptive than our method and in particular requires disruption of the cell wall, which makes simultaneous measurements of the flagellar motor impossible. Lowe et al. measured Vm
150 mV in individual mitochondria in neuroblastoma cells using a method very similar to ours (14
). Our data show large intercellular variation,
15%, in the measured values of Vm at a given pH. We measured similar cell-to-cell variation in
pNa at a given [Na+]ex (11
), indicating that individual variation between genetically identical cells extends to both components of the SMF. Based on extrapolation of the linear relationship between motor speed and
pNa, we previously predicted that Vm would be 137 mV at pH 7, in close agreement with our measured value of 140 ± 2 mV (mean ± SE) in this work. We found that
30 min was required for equilibration of dye concentrations in our experiments, presumably due to relatively low permeability of the outer membrane to dye, after our treatment with EDTA. This limits the time resolution of our technique. Faster response times may be possible by altering our method of permeabilizing the outer membrane, but care would be needed to quantify damage to cells that may be caused by such treatments.
Instability at alkaline pHex
The pH range 57 (Figs. 3 and 4) was chosen because motor rotation was stable over this range. Many chimera motors were unstable at pHex = 8 and sometimes stopped after a brief period of rapid rotation. Vm measurement in cells at pHex = 8 indicated that this was due to a collapse of Vm (see Supplementary Material).
Sodium energetics in E. coli
We have shown that Vm in E. coli varies linearly with pHex, and is independent of [Na+]ex and of the sodium flux through chimeric flagellar motors. This indicates that the membrane voltage is dominated by the balance of proton fluxes, and varies in such a way as to stabilize the PMF and internal pH as pHex changes (7
,21
).
pNa, on the other hand, depends strongly on [Na+]ex and only weakly on pHex, allowing independent control of the two components of the SMF over the ranges 85 to 140 mV in Vm and 60 to +40 mV in
pNa. Larger values of Vm are possible using alkaline pH, up to a maximum observed in this work of Vm = 165 mV and SMF = 210 mV, but the SMF is not stable under these extreme conditions in cells expressing Na+-driven chimeric flagellar motors. There is no strong evidence for the existence of a primary sodium pump in E. coli, and the best candidate for maintaining the SMF is the sodium/proton antiporter (24
). This is consistent with the weak linkage we observed between the SMF and proton energetics, especially if both components of the PMF are equally effective in maintaining the SMF.
Motor function and SMF or PMF
The relationship between motor speed and ion-motive force has been reported in different bacteria with different methods. Note that swimming speed does not directly reflect motor function in E. coli because swimming depends upon the cooperation of flagella in bundles, and therefore early experiments with swimming E. coli cells are difficult to interpret. Berg's group showed a linear relationship between motor speed and PMF up to 85 mV in tethered Streptococcus cells, using a K+ diffusion potential and a pH gradient to drive motors on starved cells (5
,6
). Further studies on glycolyzing tethered Streptococcus cells have suggested that the linear relationship between speed and PMF extends up to 150 mV (25
). Manson et al. also showed that the pH gradient and Vm were equivalent in tethered Streptococcus cells (5
). Using a micropipette to energize filamentous E. coli cells, with beads acting as markers attached to flagellar motors, Fung and Berg demonstrated the proportionality between speed and Vm up to 150 mV (3
). By observing a cell tethered to the coverslip by one motor (operating under high load) and measuring simultaneously the rotation of a second motor on the same cell (operating under lower load, marked by a 0.4-µm-diameter bead), Gabel and Berg showed that the speeds of the two motors were proportional when the PMF was gradually eliminated by adding the ionophore CCCP (4
). The high-load motor in this experiment acted as an indicator of the PMF of the cell, as previous work had shown that speed is proportional to PMF under high load. Thus, the experiment demonstrated that speed varies linearly with PMF under both load conditions, although the relative contributions of Vm and pH gradient were not known. The motor speed of sodium-driven motors in Vibrio alginolyticus has a linear dependence upon log([Na+]ex), but the SMF was not measured (26
).
In this work, we manipulated both components of the SMF by changing the pH and sodium concentration of the external medium. Sodium-driven chimeric flagellar motors under high loads imposed by 1-µm beads rotated stably at pHex between 5 and 7, and speed varied linearly with SMF from 53 to 187 mV, with no detectable difference between the two components of the SMF (Fig. 4 C). The two components of SMF were measured separately, with high accuracy, in single cells, and could be controlled on a timescale of
5 s by rapid exchange of the medium. We did not measure Vm and
pNa simultaneously in the same cell due to overlap in the emission spectra of the indicator dyes used for each measurement. Simultaneous measurements would be possible if a different dye were used for one of the measurements. The linear dependence of speed on SMF in the high-load regime is consistent with tight coupling and high efficiency (27
): the motor speed is limited neither by internal conformational changes nor by the movement of ions at these speeds. However, in the low-load regime, the motor speed shows different dependence on Vm and
pNa (Fig. 4 F). Motor speeds in low [Na+]ex are slower than those in high [Na+]ex for a given SMF. All previous comparisons of membrane voltage and ion gradient as driving forces for the flagellar motor have been under high load and have found that the two are equivalent, consistent with high efficiency and near-equilibrium behavior. At high speed and low load, we are observing the rates of reactions in the motor cycle far from equilibrium, and under these conditions the ion gradient and membrane voltage are not equivalent. The simplest explanation is that the diffusion-limited binding of sodium ions is the rate-limiting step at low load in low [Na+]ex. By controlling the SMF via Vm and
pNa, it is possible to drive the motor purely by Vm, setting
pNa at 0. It may also be possible to drive the motor purely by
pNa, using CCCP to collapse Vm and transient changes in [Na+]ex to generate a sodium gradient. Further experiments under various loads are needed for a better understanding of the motor. In particular, it will be interesting to measure torque-speed relationships with different magnitudes and components of the SMF and to use these to test models of the motor mechanism that distinguish between the contributions of electrical and chemical potential.
Driving a 1-µm bead, the motor works in the high-load regime close to thermodynamic equilibrium and the efficiency is close to 100%. For cells in a medium of pH 7 and [Na+]ex = 85 mM, the motor speed is 8.6 ± 0.8 Hz/stator and the SMF is 187 ± 15 mV. The drag coefficient is 20 ± 2 pN nm Hz1 and the work done against viscous drag in one revolution is 1087 ± 144 x 1021 J/stator. By energy balance, the minimum number of ions needed for one revolution is 36 ± 6, given by the work done divided by the free energy/ion (e x SMF = 30 ± 2 x 1021 J). With the motor driving 0.35-µm beads at low SMF ([Na+]ex = 1 mM and pH 5), a minimum of 20 ± 9 ions are required for one revolution, based on a similar calculation. Direct observation of 26 steps/revolution in the chimeric flagellar motor at low load and low SMF (10
) indicates that the number of ions required for one step at high load is >1, unless the step size is smaller at high load. At low load, it is likely that the efficiency drops and that the actual number of ions/revolution is greater than the minimum required by energy balance. Sowa et al. (10
) observed steps under conditions where motor rotation was unstable. In this work, we have identified conditions for stable slow rotation, which will allow investigation of the statistical properties of motor stepping.
| CONCLUSION |
|---|
|
|
|---|
| SUPPLEMENTARY MATERIAL |
|---|
|
|
|---|
| ACKNOWLEDGEMENTS |
|---|
|
|
|---|
C.-J.L. thanks the Swire Group/ORS for financial support. The research of R.B. and M.L. was supported by the combined United Kingdom Research Council via an Interdisciplinary Research Collaboration in Bionanotechnolgy, and that of M.L. by a Leverhulme Trust Research Fellowship.
| FOOTNOTES |
|---|
Submitted on August 14, 2006; accepted for publication February 7, 2007.
| REFERENCES |
|---|
|
|
|---|
2. Berg, H. C. 2003. The rotary motor of bacterial flagella. Annu. Rev. Biochem. 72:1954.[CrossRef][Medline]
3. Fung, D. C., and H. C. Berg. 1995. Powering the flagellar motor of Escherichia coli with an external voltage source. Nature. 357:809812.
4. Gabel, C. V., and H. C. Berg. 2003. The speed of flagellar rotary motor of Escherichia coli varies linearly with protonmotive force. Proc. Natl. Acad. Sci. USA. 100:87488751.
5. Manson, M. D., P. M. Tedesco, and H. C. Berg. 1980. Energetics of flagellar rotation in bacteria. J. Mol. Biol. 138:541561.[CrossRef][Medline]
6. Khan, S., M. Meister, and H. C. Berg. 1985. Constraints on flagellar rotation. J. Mol. Biol. 184:645656.[CrossRef][Medline]
7. Minamino, T., Y. Imae, F. Oosawa, Y. Kobayashi, and K. Oosawa. 2003. Effect of intracellular pH on rotational speed of bacterial flagellar motors. J. Bacteriol. 185:11901194.
8. Chen, X., and H. C. Berg. 2000. Solvent-isotope and pH effects on flagellar rotation in Escherichia coli. Biophys. J. 78:22802284.
9. Asai, Y., T. Yakushi, I. Kawagishi, and M. Homma. 2003. Ion-coupling determinants of Na+-driven and H+-driven flagellar motors. J. Mol. Biol. 327:453463.[CrossRef][Medline]
10. Sowa, Y., A. D. Rowe, M. C. Leake, T. Yakushi, M. Homma, A. Ishijima, and R. M. Berry. 2005. Direct observation of steps in rotation of the bacterial flagellar motor. Nature. 437:916919.[CrossRef][Medline]
11. Lo, C.-J., M. C. Leake, and R. M. Berry. 2006. Fluorescence measurement of intracellular sodium concentration in single Escherichia coli cells. Biophys. J. 90:357365.
12. Duchen, M. R., A. Leyssens, and M. Crompton. 1998. Transient mitochondrial depolarisations reflects focal sarcoplasmic reticular calcium release in single rat cardiomyocytes. J. Cell Biol. 142:975988.
13. Ehrenberg, B., V. Montana, M.-D. Wei, J. P. Wuskell, and L. M. Loew. 1988. Membrane potential can be determined in individual cells from the nernstian distribution of cationic dyes. Biophys. J. 53:785794.
14. Loew, L. M., R. A. Tuft, W. Carrington, and F. S. Fay. 1993. Imaging in five dimensions: time-dependent membrane potentials in individual mitochondria. Biophys. J. 65:23962407.
15. Scaduto, R. C., Jr., and L. W. Grotyohann. 1999. Measurement of mitochondrial membrane potential using fluorescent rhodamine derivatives. Biophys. J. 76:469477.
16. Fink, C., F. Morgan, and L. M. Loew. 1998. Intracellular fluorescent probe concentrations by confocal microscopy. Biophys. J. 75:16481658.
17. Reid, S., M. C. Leake, J. H. Chandler, C.-J. Lo, J. P. Armitage, and R. M. Berry. 2006. The maximum number of torque-generating units in the flagellar motor of Escherichia coli is at least 11. Proc. Natl. Acad. Sci. USA. 103:80668071.
18. Pilizota, T., T. Bilyard, F. Bai, H. Hosokawa, M. Futai, and R. M. Berry. 2007. A programmable optical angle clamp for rotary molecular motors. Biophys. J. In press.
19. Leake, M. C., J. H. Chandler, G. H. Wadhams, F. Bai, R. M. Berry, and J. P. Armitage. 2006. Stoichiometry and turnover in single, functioning membrane protein complexes. Nature. 443:355358.[CrossRef][Medline]
20. Felle, H., J. S. Porter, C. L. Slayman, and H. R. Kaback. 1980. Quantitative measurements of membrane potential in Escherichia coli. Biochemistry. 19:35853590.[CrossRef][Medline]
21. Castle, A. M., R. M. Macnab, and R. G. Shulman. 1986. Coupling between the sodium and proton gradients in respiring Escherichia coli cells measured by 23Na and 31P nuclear magnetic resonance. J. Biochem. (Tokyo). 261:77977806.
22. Novo, D., N. G. Perlmutter, R. H. Hunt, and H. M. Shapiro. 1999. Accurate flow cytometric membrane potential measurement in bacteria using diethyloxacarbocynine and a ratiometric technique. Cytometry. 35:5563.[CrossRef][Medline]
23. Suzuki, H., Z. Wang, M. Yamakoshi, M. Kobayashi, and T. Nozawa. 2003. Probing the transmembrnae potential of bacterial cells by voltage-sensitive dyes. Anal. Sci. 19:12391242.[CrossRef][Medline]
24. Padan, E., M. Venturi, Y. Gerchman, and N. Dover. 2001. Na+/H+ antiporters. Biochim. Biophys. Acta. 1505:144157.[Medline]
25. Meister, M., and H. C. Berg. 1987. The stall torque of the bacterial flagellar motor. Biophys. J. 52:413419.
26. Sowa, Y., H. Hotta, M. Homma, and A. Ishijima. 2003. Torque-speed relationship of the Na+-driven flagellar motor of Vibrio alginolyticus. J. Mol. Biol. 327:10431051.[CrossRef][Medline]
27. Xing, J., F. Bai, R. M. Berry, and G. Oster. 2006. Torque-speed relationship of the bacterial flagellar motor. Proc. Natl. Acad. Sci. USA. 103:12601265.
This article has been cited by other articles:
![]() |
M. C. Leake, N. P. Greene, R. M. Godun, T. Granjon, G. Buchanan, S. Chen, R. M. Berry, T. Palmer, and B. C. Berks Variable stoichiometry of the TatA component of the twin-arginine protein transport system observed by in vivo single-molecule imaging PNAS, October 7, 2008; 105(40): 15376 - 15381. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||