help button home button Biophys. J.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH

Biophys. J. BioFAST: First Published November 8, 2004. doi:10.1529/biophysj.104.047001
© 2004 by the Biophysical Society.


A more recent version of this article appeared on February 1, 2005.
This Article
Right arrow Full Text (Rapid PDF)
Right arrow All Versions of this Article:
biophysj.104.047001v1
88/2/1432    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mody, N. A.
Right arrow Articles by King, M. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mody, N. A.
Right arrow Articles by King, M. R.

CELL BIOPHYSICS

Mechanics of transient platelet adhesion to von Willebrand factor under flow

Nipa A. Mody 1, Oleg Lomakin 1, Teresa A. Doggett 2, Thomas G. Diacovo 2 and Michael R. King 1*

1 University of Rochester
2 Washington University School of Medicine

* To whom correspondence should be addressed. E-mail: mike_king{at}urmc.rochester.edu.

Submitted on June 2, 2004
Revised on July 27, 2004
Accepted on 1 November 2004


   Abstract
A primary and critical step in platelet attachment to injured vascular endothelium is the formation of reversible tether bonds between the platelet glycoprotein receptor Ib{alpha} and the A1 domain of surface-bound von Willebrand factor (vWF). Due to the platelet's unique ellipsoidal shape, the force mechanics involved in its tether bond formation differs significantly from that of leukocytes and other spherical cells. We have investigated the mechanics of platelet tethering to surface-immobilized vWF-A1 under hydrodynamic shear flow. A computer algorithm was used to analyze digitized images recorded during flow-chamber experiments and track the microscale motions of platelets before, during and after contact with the surface. An analytical 2-D model was developed to calculate the motion of a tethered platelet on a reactive surface in linear shear flow. Through comparison of the theoretical solution with experimental observations, we show that attachment of platelets occurs only in orientations that are predicted to result in compression along the length of the platelet and therefore on the bond being formed. These results suggest that hydrodynamic compressive forces may play an important role in initiating tether bond formation.

Key Words: Stokes flow, cell adhesion, hydrodynamics, platelet, von Willebrand factor




This article has been cited by other articles:


Home page
Biophys. JHome page
N. A. Mody and M. R. King
Platelet Adhesive Dynamics. Part I: Characterization of Platelet Hydrodynamic Collisions and Wall Effects
Biophys. J., September 1, 2008; 95(5): 2539 - 2555.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
M. J. Maxwell, S. M. Dopheide, S. J. Turner, and S. P. Jackson
Shear Induces a Unique Series of Morphological Changes in Translocating Platelets: Effects of Morphology on Translocation Dynamics
Arterioscler. Thromb. Vasc. Biol., March 1, 2006; 26(3): 663 - 669.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2004 by the Biophysical Society.